Vortex Flowmeter AVT2000
Vortex Flowmeter
Introduction
Vortex Flowmeter is on the principle of Karmon vortex street, to measure liquid, gas and vapor even turbid liquid including micro-grain and impurity. Main Applications : petroleum, chemical industry, paper making, metallurgy, electric force, environmental protection, food industry and etc.
Technology Parameters
Medium : Liquid, Gas, Steam
Inside Nominal Diameter ~ AVT Pipeline-type : DN50
Accuracy : AVT-Pipeline type 1.0%
Flow range : 0000m³/hr ~ 90000m³/hr (see tention report)
Norminal Pressure- : AVT-Pipelined Flanged type : DN10 ~ DN500 ~ DN2000
Midium temperature : AVT-Pipelined type -40℃ ~ +420℃
Ambient temperature : -20℃ ~ +40℃ (Expiosion-proof Mold)
Relative humidity : 5% ~ 95%RH
Atmospheric pressure : 86kPa-106kPa
Electrical interface : M20*1.5 female screw
Working Power : 24VDC±5%
Protection level : IP65 (IP67 & IP68 For optional)
Housing material : Aluminum Alloy (IP65)
Pressure lose :
Calibration : factory calibration, following china standard date from international Standard)
Display : English Version (flow rate, totalizer, working condition flow rate, working condition temperature, working condition pressure, battery power, density, output, time, menu changes records, Essential setting as per customer provided specilications and parameters)
Above specifications is reference, some description will not selected in you flowmeter. But we strictly follow sales confirmation confirmed specification.
technical parameter
Series |
|||
|---|---|---|---|
Typical Diameter |
Wafer design DN15~DN300, Flanges DN15~DN600, Insert design>= DN300 |
||
Typical pressure |
(1.6, 2.0, 2.5, 4.0, 5.0, 6.4)Mpa, other special pressure classes upon request |
||
Fluid temperature |
Standard (-40 ~+150) ℃, M-temp (-40 ~ +280 ) °℃ , H-temp (-40 ~ +420 ) ℃ |
||
Sensor design |
Single sensor , Double sensor |
||
Body material |
SUS304, SUS316 |
||
Accuracy |
0.2% ~ 2.5% |
||
Reproducibility |
<0.33% |
||
Flow Range |
1:10 ~ 1:20 |
||
Converter type |
Compact Remote Submersible |
||
Communication |
RS485, RS232 |
||
Display |
2×8 characer |
4×12 characer accumulate/tempora |
Accumulate/Temp/Pressure |
Temp/Pressure- |
- |
- |
YES |
Supply power |
Transmitter power : 24VDC, 24VDC(Digital filtering required), |
||
Contact output |
AVT2000:4-20mA Pulse Voltage: L 1V, H≥5V |
current:4-20mA Pulse Voltage: L<1V, H≥5V |
current:4-20mA Pulse Voltage: L<1V, H≥5V |
Battery power |
- |
- |
YES |
Linear correction |
- |
- |
YES |
remote flow cut- |
AVT2000 |
YES |
YES |
Protection Class |
IP65, IP67 |
||
Required fluid |
gas,liquid,steam |
||
Ambient |
Ambient temperature : (-40~+40)℃ |
||
Detailed specification sheets are shown in the product images.
Catalogues
Vortex Flowmeter AVT2000
Vortex Flowmeter AVT2000: overview and buying guide
The Vortex Flowmeter AVT2000 (model AVT2000) is made by AUTOFLOW and listed in our chemical range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Vortex Flowmeter AVT2000 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Vortex Flowmeter AVT2000 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine AUTOFLOW product?
We purchase directly from AUTOFLOW or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Vortex Flowmeter
Introduction
Vortex Flowmeter is on the principle of Karmon vortex street, to measure liquid, gas and vapor even turbid liquid including micro-grain and impurity. Main Applications : petroleum, chemical industry, paper making, metallurgy, electric force, environmental protection, food industry and etc.
Technology Parameters
Medium : Liquid, Gas, Steam
Inside Nominal Diameter ~ AVT Pipeline-type : DN50
Accuracy : AVT-Pipeline type 1.0%
Flow range : 0000m³/hr ~ 90000m³/hr (see tention report)
Norminal Pressure- : AVT-Pipelined Flanged type : DN10 ~ DN500 ~ DN2000
Midium temperature : AVT-Pipelined type -40℃ ~ +420℃
Ambient temperature : -20℃ ~ +40℃ (Expiosion-proof Mold)
Relative humidity : 5% ~ 95%RH
Atmospheric pressure : 86kPa-106kPa
Electrical interface : M20*1.5 female screw
Working Power : 24VDC±5%
Protection level : IP65 (IP67 & IP68 For optional)
Housing material : Aluminum Alloy (IP65)
Pressure lose :
Calibration : factory calibration, following china standard date from international Standard)
Display : English Version (flow rate, totalizer, working condition flow rate, working condition temperature, working condition pressure, battery power, density, output, time, menu changes records, Essential setting as per customer provided specilications and parameters)
Above specifications is reference, some description will not selected in you flowmeter. But we strictly follow sales confirmation confirmed specification.
technical parameter
Series |
|||
|---|---|---|---|
Typical Diameter |
Wafer design DN15~DN300, Flanges DN15~DN600, Insert design>= DN300 |
||
Typical pressure |
(1.6, 2.0, 2.5, 4.0, 5.0, 6.4)Mpa, other special pressure classes upon request |
||
Fluid temperature |
Standard (-40 ~+150) ℃, M-temp (-40 ~ +280 ) °℃ , H-temp (-40 ~ +420 ) ℃ |
||
Sensor design |
Single sensor , Double sensor |
||
Body material |
SUS304, SUS316 |
||
Accuracy |
0.2% ~ 2.5% |
||
Reproducibility |
<0.33% |
||
Flow Range |
1:10 ~ 1:20 |
||
Converter type |
Compact Remote Submersible |
||
Communication |
RS485, RS232 |
||
Display |
2×8 characer |
4×12 characer accumulate/tempora |
Accumulate/Temp/Pressure |
Temp/Pressure- |
- |
- |
YES |
Supply power |
Transmitter power : 24VDC, 24VDC(Digital filtering required), |
||
Contact output |
AVT2000:4-20mA Pulse Voltage: L 1V, H≥5V |
current:4-20mA Pulse Voltage: L<1V, H≥5V |
current:4-20mA Pulse Voltage: L<1V, H≥5V |
Battery power |
- |
- |
YES |
Linear correction |
- |
- |
YES |
remote flow cut- |
AVT2000 |
YES |
YES |
Protection Class |
IP65, IP67 |
||
Required fluid |
gas,liquid,steam |
||
Ambient |
Ambient temperature : (-40~+40)℃ |
||
Detailed specification sheets are shown in the product images.