Electromagnetic Heat Meter E-MAG-R-E
Electromagnetic Heat Meter
Summary
Electromagnetic heat meter is made with international latest technology, used to measure the heat volume of the heat transporting fluid in thermal transfer system. It has adopted platinum thermal resistance for temperature measurement with high accuracy, high stability, which can be widely used for heat metering in central heating system of civilian residential area, office building and enterprises.
Principle of Measurement
The electromagnetic heat meter works according to electromagnetic induction law of Faraday. The sensor is mainly composed of measuring tube with isolated lining, a pair of electrodes in stalled by penetration of the measuring tube wall, a pair of cols and iron core to produce working magnetic field. When the heat transporting fluid flows through the measuring tube, the voltage signal in direct proportion to the average flow velocity of the fluid will be inducted on the electrodes, and the temperature difference can be inducted by the temperature sensor on the transmitter, then heat difference can be calculated and showed through the display.
Composition
The electromagnetic heat meter is composed of flow sensor, transmitter, and cable with temperature sensor, it is usually formed in remote model
Specification
Model |
E-MAG-R-E (Heat Meter) |
|---|---|
Size |
10A~1600A |
Velocity |
0.3m/s-10m/s |
Electroide |
STS316L Standard (Hast-C, Tantalum, Titanum, Platinum, etc) |
Liner |
PTFE Standard (PU, NBR, PFA, FEP) Hard rubber |
Flange |
SUS304(10A-250A); Carbon Steel(300A-1600A) |
Accuracy |
±0.5% Reading (Flow Velocity≥1m/s) |
Fluid Temp. |
-20℃~+60℃(PU Liner), -20℃~+120℃(PTFE Liner) |
Ambient Temp. |
-20℃~+55℃ |
Pressure |
1.0MPa |
Connection |
JIS 10K RF FLANGE (ANSI, DIN ... ) |
Power Supply |
85-265V AC, 50/60Hz(Standard); 18~36V DC Power < 15W |
Output Signal |
Current:4~20mA, Load resistance < 5002 / Open collector(NPN) pulse |
Communication |
RS485 Modbus |
Display |
LCD Display(Back-light provided) |
※ The PT 1000Ω temperature sensor is sold separately.
Dimensions
Size (mm) |
Pressure (Mpa) |
Outline Size (mm) |
Flange Size (mm |
Weight (kg) |
||||
|---|---|---|---|---|---|---|---|---|
L |
H |
D |
K |
n-d |
C |
|||
10 |
4.0 |
160 |
198 |
90 |
65 |
4-15 |
12 |
8 |
15 |
4.0 |
160 |
198 |
95 |
70 |
4-15 |
12 |
8 |
20 |
4.0 |
200 |
199 |
100 |
75 |
4-15 |
14 |
9 |
25 |
4.0 |
200 |
212 |
125 |
90 |
4-19 |
14 |
10 |
32 |
4.0 |
200 |
217 |
135 |
100 |
4-19 |
16 |
11 |
40 |
4.0 |
200 |
234 |
140 |
105 |
4-19 |
16 |
12 |
50 |
4.0 |
200 |
242 |
155 |
120 |
4-19 |
16 |
13 |
65 |
4.0 |
200 |
262 |
175 |
140 |
4-19 |
18 |
16 |
80 |
4.0 |
200 |
272 |
185 |
150 |
8-19 |
18 |
16 |
100 |
1.6 |
250 |
297 |
210 |
175 |
8-19 |
18 |
19 |
125 |
1.6 |
250 |
332 |
250 |
210 |
8-23 |
20 |
25 |
150 |
1.6 |
300 |
375 |
280 |
240 |
8-23 |
22 |
36 |
200 |
1.6 |
350 |
426 |
330 |
290 |
12-23 |
22 |
50 |
250 |
1.6 |
400 |
485 |
400 |
355 |
12-25 |
24 |
63 |
300 |
1.6 |
500 |
535 |
445 |
400 |
16-25 |
24 |
73 |
350 |
1.6 |
600 |
583 |
490 |
445 |
16-25 |
26 |
91 |
400 |
1.6 |
600 |
633 |
560 |
510 |
16-27 |
28 |
107 |
450 |
1.0 |
600 |
696 |
620 |
565 |
20-27 |
30 |
127 |
500 |
1.0 |
600 |
753 |
675 |
620 |
20-27 |
30 |
150 |
600 |
1.0 |
600 |
857 |
795 |
730 |
24-33 |
32 |
197 |
700 |
1.0 |
700 |
980 |
905 |
840 |
24-33 |
34 |
255 |
800 |
1.0 |
800 |
1091 |
1020 |
950 |
28-33 |
36 |
339 |
Detailed specification sheets are shown in the product images.
Catalogues
Electromagnetic Heat Meter E-MAG-R-E
Electromagnetic Heat Meter E-MAG-R-E: overview and buying guide
The Electromagnetic Heat Meter E-MAG-R-E (model E-MAG-R-E) is made by AUTOFLOW and listed in our chemical range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Electromagnetic Heat Meter E-MAG-R-E cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Electromagnetic Heat Meter E-MAG-R-E to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine AUTOFLOW product?
We purchase directly from AUTOFLOW or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Electromagnetic Heat Meter
Summary
Electromagnetic heat meter is made with international latest technology, used to measure the heat volume of the heat transporting fluid in thermal transfer system. It has adopted platinum thermal resistance for temperature measurement with high accuracy, high stability, which can be widely used for heat metering in central heating system of civilian residential area, office building and enterprises.
Principle of Measurement
The electromagnetic heat meter works according to electromagnetic induction law of Faraday. The sensor is mainly composed of measuring tube with isolated lining, a pair of electrodes in stalled by penetration of the measuring tube wall, a pair of cols and iron core to produce working magnetic field. When the heat transporting fluid flows through the measuring tube, the voltage signal in direct proportion to the average flow velocity of the fluid will be inducted on the electrodes, and the temperature difference can be inducted by the temperature sensor on the transmitter, then heat difference can be calculated and showed through the display.
Composition
The electromagnetic heat meter is composed of flow sensor, transmitter, and cable with temperature sensor, it is usually formed in remote model
Specification
Model |
E-MAG-R-E (Heat Meter) |
|---|---|
Size |
10A~1600A |
Velocity |
0.3m/s-10m/s |
Electroide |
STS316L Standard (Hast-C, Tantalum, Titanum, Platinum, etc) |
Liner |
PTFE Standard (PU, NBR, PFA, FEP) Hard rubber |
Flange |
SUS304(10A-250A); Carbon Steel(300A-1600A) |
Accuracy |
±0.5% Reading (Flow Velocity≥1m/s) |
Fluid Temp. |
-20℃~+60℃(PU Liner), -20℃~+120℃(PTFE Liner) |
Ambient Temp. |
-20℃~+55℃ |
Pressure |
1.0MPa |
Connection |
JIS 10K RF FLANGE (ANSI, DIN ... ) |
Power Supply |
85-265V AC, 50/60Hz(Standard); 18~36V DC Power < 15W |
Output Signal |
Current:4~20mA, Load resistance < 5002 / Open collector(NPN) pulse |
Communication |
RS485 Modbus |
Display |
LCD Display(Back-light provided) |
※ The PT 1000Ω temperature sensor is sold separately.
Dimensions
Size (mm) |
Pressure (Mpa) |
Outline Size (mm) |
Flange Size (mm |
Weight (kg) |
||||
|---|---|---|---|---|---|---|---|---|
L |
H |
D |
K |
n-d |
C |
|||
10 |
4.0 |
160 |
198 |
90 |
65 |
4-15 |
12 |
8 |
15 |
4.0 |
160 |
198 |
95 |
70 |
4-15 |
12 |
8 |
20 |
4.0 |
200 |
199 |
100 |
75 |
4-15 |
14 |
9 |
25 |
4.0 |
200 |
212 |
125 |
90 |
4-19 |
14 |
10 |
32 |
4.0 |
200 |
217 |
135 |
100 |
4-19 |
16 |
11 |
40 |
4.0 |
200 |
234 |
140 |
105 |
4-19 |
16 |
12 |
50 |
4.0 |
200 |
242 |
155 |
120 |
4-19 |
16 |
13 |
65 |
4.0 |
200 |
262 |
175 |
140 |
4-19 |
18 |
16 |
80 |
4.0 |
200 |
272 |
185 |
150 |
8-19 |
18 |
16 |
100 |
1.6 |
250 |
297 |
210 |
175 |
8-19 |
18 |
19 |
125 |
1.6 |
250 |
332 |
250 |
210 |
8-23 |
20 |
25 |
150 |
1.6 |
300 |
375 |
280 |
240 |
8-23 |
22 |
36 |
200 |
1.6 |
350 |
426 |
330 |
290 |
12-23 |
22 |
50 |
250 |
1.6 |
400 |
485 |
400 |
355 |
12-25 |
24 |
63 |
300 |
1.6 |
500 |
535 |
445 |
400 |
16-25 |
24 |
73 |
350 |
1.6 |
600 |
583 |
490 |
445 |
16-25 |
26 |
91 |
400 |
1.6 |
600 |
633 |
560 |
510 |
16-27 |
28 |
107 |
450 |
1.0 |
600 |
696 |
620 |
565 |
20-27 |
30 |
127 |
500 |
1.0 |
600 |
753 |
675 |
620 |
20-27 |
30 |
150 |
600 |
1.0 |
600 |
857 |
795 |
730 |
24-33 |
32 |
197 |
700 |
1.0 |
700 |
980 |
905 |
840 |
24-33 |
34 |
255 |
800 |
1.0 |
800 |
1091 |
1020 |
950 |
28-33 |
36 |
339 |
Detailed specification sheets are shown in the product images.