{"product_id":"xeuss-3-0-138607","title":"Xeuss 3.0","description":"\u003ch3\u003eOverview\u003c\/h3\u003e \u003cp\u003e\u003cstrong\u003eThe Next Generation beamline \u003c\/strong\u003e\u003cstrong\u003efor the laboratory\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMaximum flexibility\u003c\/li\u003e \u003cli\u003eUltimate performance\u003c\/li\u003e \u003cli\u003ePlenty of space for sample environment\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe Xeuss 3.0 is the latest generation instrument in the proven Xeuss family and is already installed in leading research facilities around the world. It incorporates all the latest innovations from Xenocs for added capabilities, flexibility and ease-of-use.\u003c\/p\u003e \u003cp\u003e\u003cem\u003e“The Xeuss is a fantastic boost to our research. We use it a lot in combination with synchrotron experiments.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eBefore going to the synchrotron, we use it to select the best samples, improve sample preparation process and perform preliminary analysis. Then, when back in Sheffield, we can refine data with the Xeuss, for publication and further research.”\u003c\/em\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDr. Oleksandr Mykhaylyk, the University of Sheffield, UK\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eAccelerate your research\u003c\/strong\u003e The Xeuss 3.0 is used for many applications. Select your application \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eSize, structure, shape, orientation...\u003c\/strong\u003e Characterize the nanostructure of soft-matter and nanomaterials using SAXS\/WAXS and USAXS technique in transmission or grazing incidence mode. \u003cul\u003e \u003cli\u003eParticle size distribution ranging from few nanometers to more than 350 nm in diameter\u003c\/li\u003e \u003cli\u003eCrystallization rates and lamellar structure of semicrystalline polymers\u003c\/li\u003e \u003cli\u003eSize and shape analysis of surfactants or proteins in solutions\u003c\/li\u003e \u003cli\u003eOrganization and orientation of nanomaterials at atomic or nanoscale, in bulk phases or at surfaces\u003c\/li\u003e \u003cli\u003ePhase segregation studies of alloys\u003c\/li\u003e \u003cli\u003eIn situ studies of nanostructure transitions\u003c\/li\u003e \u003c\/ul\u003e Select the characterization you are interested in \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eDiscover our application notes :\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eDetermination of polymer crystallinity\u003c\/p\u003e \u003cp\u003eLow detection limit of crystallinity\u003c\/p\u003e \u003cp\u003eProtein structure resolution\u003c\/p\u003e \u003cp\u003eSilk fiber nanostructure investigation\u003c\/p\u003e \u003cp\u003eInvestigation of Gold Nanoparticles\u003c\/p\u003e\u003ch3\u003eBenefits \u0026amp; Features\u003c\/h3\u003e\u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eMaximum flexibility\u003c\/strong\u003e Provide structural tools to a large community of users with full remote operation capability and access to a unique range of length-scales. Advanced nanomaterials development and design require characterization over a large range of length scales. The Xeuss 3.0 offers such measuring capability over up to 5 orders in magnitude in q (wave vector) through entirely motorized change of configurations. Any trained user can thus operate the system remotely over its complete measurement range for a given sample or batch of samples. Automatic change of measuring settings include: \u003cul\u003e \u003cli\u003eQ-Xoom change of measurement resolution through motorized translation of detector\u003c\/li\u003e \u003cli\u003eSequential SAXS \/USAXS measurement with Bonse-Hart USAXS module\u003c\/li\u003e \u003cli\u003eChange of energy radiation, up to 3 energies\u003c\/li\u003e \u003cli\u003eMovable WAXS detector for out of equilibrium in situ SWAXS studies\u003c\/li\u003e \u003cli\u003eInXight X-ray imaging module\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003chr\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eUltimate performance\u003c\/strong\u003e The Xeuss 3.0 offers a maximum flexibility of measurement configurations to get the best possible data quality on any type of sample. In particular, the following key features enable the user to optimize experiments or results: \u003cul\u003e \u003cli\u003eHigh flux settings adapted for fast kinetics embedded in a low background camera\u003c\/li\u003e \u003cli\u003eLargest surface of detection moveable all the way from WAXS to long distance SAXS to optimize resolution and signal-to-noise\u003c\/li\u003e \u003cli\u003eLong distance SAXS settings for measuring large characteristic dimensions (\u0026gt; 300 nm)\u003c\/li\u003e \u003cli\u003eOptional USAXS module to characterize large structures ( \u0026gt; 4 µm)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd\u003e \u003cbr\u003eXeuss 3.0 shown with Q-Xoom transparency to illustrate the moving detector. \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003chr\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003ePlenty of space for sample environment\u003c\/strong\u003e With its large chamber and concept ensuring stationary sample during measurement, the Xeuss 3.0 is the perfect X-ray scattering platform instrument for now and the future. Advanced materials research and characterization could require integration of specific or customized sample environments.\u003cbr\u003eXeuss 3.0 is perfectly adapted for such new projects thanks to its state of the art beamline concept.\u003cbr\u003eIt provides: \u003cul\u003e \u003cli\u003eLarge vacuum chamber with stationary sample during measurement (continuous on-axis sample viewing, smart integration of customized sample environments)\u003c\/li\u003e \u003cli\u003eSample stage with long translations for sample mapping and batch measurements\u003c\/li\u003e \u003cli\u003eBroad range of standard sample environments with holder recognition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-7c1b4becb708c0f3.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-Xenocs-Xeuss 3.0\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"XENOCS SAS","offers":[{"title":"Default Title","offer_id":58447611953492,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/db828624-f57f-4d66-aba3-6dee0dae5eda.jpg?v=1795193284","url":"https:\/\/premiumemart.com\/products\/xeuss-3-0-138607","provider":"Premium Emart","version":"1.0","type":"link"}