{"product_id":"wastewater-heat-source-heat-pump-60714","title":"Wastewater Heat Source Heat Pump IWBP-12BA Series","description":"\u003cp\u003e\u003cstrong\u003e* Product Overview\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eHeat pump system that recovers sensible heat from wastewater to supply hot water production and heating systems.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e* Product Features\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e① Dual-cycle product → 70℃ production possible (R22 + R410A)\u003c\/p\u003e \u003cp\u003e- A product that maximizes the advantages of each refrigerant.\u003c\/p\u003e \u003cp\u003e- Even if the temperature of the hot water entering the heat pump exceeds 50~55℃, the machine can operate normally, allowing for a wider range of operation.\u003c\/p\u003e \u003cp\u003e② Convenience\u003c\/p\u003e \u003cp\u003e· PCB automatic control system applied as standard\u003cbr\u003e - Switch control function\u003cbr\u003e - PCB contact, ON\/OFF function\u003cbr\u003e - Data input function\u003cbr\u003e - Special function for screen switching\u003c\/p\u003e \u003cp\u003e· Automatic control function\u003cbr\u003e - Outlet water temperature setting function\u003cbr\u003e - Cumulative operating time calculation function\u003cbr\u003e - Operation\/stop time setting function\u003cbr\u003e - High\/low pressure display\u003cbr\u003e - Day of the week operation setting function\u003cbr\u003e - Abnormal operation alarm function\u003c\/p\u003e \u003cp\u003e③ Minimize defect rate\u003c\/p\u003e \u003cp\u003e- Increased lifespan due to the use of not only copper evaporators but also stainless steel evaporators (SUS316) depending on water quality.\u003c\/p\u003e \u003cp\u003e④ Inverter control system installed as standard - user can control the desired temperature.\u003c\/p\u003e \u003cp\u003e- By using a bare-tube (immersion type) evaporator and simultaneously installing an air bubbling device (blower) at the bottom of the wastewater tank as standard, thermal efficiency is increased, and foreign matter in the wastewater is prevented from adhering to the evaporator. If foreign matter adheres, cleaning is easy through the manhole installed in the wastewater tank.\u003c\/p\u003e \u003cp\u003e⑤ B\/S (Before Service)\u003c\/p\u003e \u003cp\u003e- B\/S is possible by connecting the heat pump system to a computer (monitoring system).\u003c\/p\u003e \u003cp\u003e⑥ Use of SUS316 high-pressure condenser\u003c\/p\u003e \u003cp\u003e- High corrosion resistance\u003c\/p\u003e \u003cp\u003e- High operating temperature (can be used even at 45bar~70bar because it is manufactured through vacuum welding)\u003c\/p\u003e \u003cp\u003e- Made of SUS316 material, allowable temperature up to 200℃ can be used.\u003c\/p\u003e \u003cp\u003e- Lightweight\u003c\/p\u003e \u003cp\u003e- High heat exchange capacity\u003c\/p\u003e \u003cp\u003e⑦ Use of SUS316 evaporator\u003c\/p\u003e \u003cp\u003e- Industry's first to adopt SUS316 pipe as standard\u003cbr\u003e ※ Maximized durability compared to existing copper pipes and SUS304 pipes\u003c\/p\u003e \u003cp\u003e- Minimized welding areas\u003cbr\u003e ※ SUS316 evaporator is constructed with 6M piping, and by applying argon welding method compared to other companies, welding areas are minimized, reducing the defect rate.\u003c\/p\u003e \u003cp\u003e⑧ Air Pump System\u003c\/p\u003e \u003cp\u003e- By installing an air aeration system (blower) in the wastewater tank, the generated air bubbles not only provide a sludge removal effect but also maximize heat transfer in the evaporator.\u003c\/p\u003e \u003cp\u003e⑨ EVI Compressor Application (R-410A side)\u003c\/p\u003e \u003cp\u003e- Similar concept to two-stage compression, it involves gas injection into the compressor scroll to lower the condensed liquid refrigerant temperature, and is configured with two suction ports and one discharge port in the compressor.\u003c\/p\u003e \u003cp\u003e- By separating gas without heat absorption capability entering the evaporator in the refrigerant cycle and injecting it into the compressor's medium pressure (Vapor Injection) port, performance in the evaporator and compression work in the compressor are reduced, thereby saving energy consumption.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e* Applications\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eApplicable everywhere wastewater is generated and hot water is needed. It absorbs high-temperature (20~30℃) wastewater heat, and the waste heat recovery heat pump uses electrical energy to produce hot water at the temperature actually needed in bathhouses. It is a product that achieves a COP of about 4~5 compared to general electric boilers.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e* Wastewater Source Heat Pump Product (IWBP-12BA Series) Specifications\u003c\/strong\u003e\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eModel\u003c\/th\u003e \u003cth\u003eIWBP- 12BA-40\u003c\/th\u003e \u003cth\u003eIWBP- 12BA-45\u003c\/th\u003e \u003cth\u003eIWBP- 12BA-46\u003c\/th\u003e \u003cth\u003eIWBP- 12BA-51\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"4\"\u003ePerformance\u003c\/td\u003e \u003ctd\u003eKW\u003c\/td\u003e \u003ctd\u003e141\u003c\/td\u003e \u003ctd\u003e158\u003c\/td\u003e \u003ctd\u003e162\u003c\/td\u003e \u003ctd\u003e179\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eKcal\/h\u003c\/td\u003e \u003ctd\u003e121,300\u003c\/td\u003e \u003ctd\u003e135,900\u003c\/td\u003e \u003ctd\u003e139,700\u003c\/td\u003e \u003ctd\u003e154,300\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUSRT\u003c\/td\u003e \u003ctd\u003e40\u003c\/td\u003e \u003ctd\u003e45\u003c\/td\u003e \u003ctd\u003e46\u003c\/td\u003e \u003ctd\u003e51\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHot water production\u003c\/td\u003e \u003ctd\u003e2,888\u003c\/td\u003e \u003ctd\u003e3,236\u003c\/td\u003e \u003ctd\u003e3,326\u003c\/td\u003e \u003ctd\u003e3,674\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003ePower Consumption\u003c\/td\u003e \u003ctd\u003eKW\u003c\/td\u003e \u003ctd\u003e36\u003c\/td\u003e \u003ctd\u003e40\u003c\/td\u003e \u003ctd\u003e42\u003c\/td\u003e \u003ctd\u003e46\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"3\"\u003ePower Supply\u003c\/td\u003e \u003ctd colspan=\"4\"\u003e3-phase * 380V * 60Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003eHorsepower\u003c\/td\u003e \u003ctd\u003eHP\u003c\/td\u003e \u003ctd\u003e36\u003c\/td\u003e \u003ctd\u003e40\u003c\/td\u003e \u003ctd\u003e42\u003c\/td\u003e \u003ctd\u003e46\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"3\"\u003eExternal Dimensions\u003c\/td\u003e \u003ctd\u003eLength\u003c\/td\u003e \u003ctd rowspan=\"3\"\u003emm\u003c\/td\u003e \u003ctd colspan=\"4\"\u003e1,200\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd colspan=\"4\"\u003e1,940\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd colspan=\"4\"\u003e760\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"5\"\u003eCompressor\u003c\/td\u003e \u003ctd colspan=\"2\"\u003eType\u003c\/td\u003e \u003ctd colspan=\"4\"\u003eScroll\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003eNumber of units\u003c\/td\u003e \u003ctd colspan=\"4\"\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003eStarting Method\u003c\/td\u003e \u003ctd colspan=\"4\"\u003eDirect Online Starting\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCapacity Control\u003c\/td\u003e \u003ctd\u003e%\u003c\/td\u003e \u003ctd colspan=\"4\"\u003e0 ~ 100%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLegal Refrigeration Capacity\u003c\/td\u003e \u003ctd\u003eRT\u003c\/td\u003e \u003ctd\u003e12.56\u003c\/td\u003e \u003ctd\u003e13.88\u003c\/td\u003e \u003ctd\u003e14.52\u003c\/td\u003e \u003ctd\u003e15.84\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003eRefrigerant\u003c\/td\u003e \u003ctd colspan=\"2\"\u003eType\u003c\/td\u003e \u003ctd colspan=\"4\"\u003e1st stage: R-22, 2nd stage: R-410A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003eControl\u003c\/td\u003e \u003ctd colspan=\"4\"\u003eThermostatic Expansion Valve\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"3\"\u003eLoad side\u003cbr\u003e heat exchanger\u003c\/td\u003e \u003ctd colspan=\"2\"\u003eType\u003c\/td\u003e \u003ctd colspan=\"4\"\u003eBRAZED PLATE TYPE\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCirculation Water Volume\u003c\/td\u003e \u003ctd\u003eLPM\u003c\/td\u003e \u003ctd\u003e48\u003c\/td\u003e \u003ctd\u003e54\u003c\/td\u003e \u003ctd\u003e55\u003c\/td\u003e \u003ctd\u003e61\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePiping (IN\/OUT)\u003c\/td\u003e \u003ctd\u003eA\u003c\/td\u003e \u003ctd\u003e50\u003c\/td\u003e \u003ctd\u003e50\u003c\/td\u003e \u003ctd\u003e50\u003c\/td\u003e \u003ctd\u003e50\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeat source side\u003cbr\u003e heat exchanger\u003c\/td\u003e \u003ctd colspan=\"2\"\u003eType\u003c\/td\u003e \u003ctd colspan=\"4\"\u003eSpiral Tube Type\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003eControl Method\u003c\/td\u003e \u003ctd colspan=\"2\"\u003eTemperature Control\u003c\/td\u003e \u003ctd colspan=\"4\"\u003eInlet\/Outlet Automatic Temperature Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003eOperation Control\u003c\/td\u003e \u003ctd colspan=\"4\"\u003ePCB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003eWeight\u003c\/td\u003e \u003ctd\u003eKG\u003c\/td\u003e \u003ctd\u003e520\u003c\/td\u003e \u003ctd\u003e580\u003c\/td\u003e \u003ctd\u003e620\u003c\/td\u003e \u003ctd\u003e660\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"3\"\u003e[Product Conditions]\u003c\/td\u003e \u003ctd colspan=\"4\"\u003eCondition: Wastewater temperature 25℃, supply water temperature 28℃, outlet water temperature 70℃\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e■ The above specifications may vary depending on site conditions and temperature conditions.\u003cbr\u003e ■ The specifications and external dimensions of the above products may be changed without prior notice according to our company's regulations.\u003c\/p\u003e","brand":"IL-JIN E-PLUS","offers":[{"title":"Default Title","offer_id":58446204862804,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/pem-stock-hydraulic-fluid.jpg?v=1795222000","url":"https:\/\/premiumemart.com\/products\/wastewater-heat-source-heat-pump-60714","provider":"Premium Emart","version":"1.0","type":"link"}