Vortex Tube

Key Features

  • A Vortex Tube is a device that separates a stream of compressed air (approximately 3–9.9 kgf/cm², 2–9.9 bar) into two distinct air streams—cold air and hot air—through an internal energy separation process.
    This mechanism enables localized cooling (Local Cooling) without the use of electrical power or refrigerants, making it an environmentally friendly cooling solution.

  • The device features a simple and robust design with no moving or rotating parts, which minimizes maintenance requirements while ensuring stable and highly reliable operation.

  • In addition, a Vortex Tube can generate instant cold air using only compressed air, eliminating the need for electrical power supply or complex cooling systems. For this reason, it is widely used as an efficient cooling solution in industrial environments, laboratories, and automation systems where localized cooling is required.
    Typical applications include:
    - Cooling of industrial equipment and control panels
    - Cooling in machining processes
    - Protection of electronic equipment and sensors
    - Localized cooling for laboratory instruments
    - Cooling of automation equipment and production lines

  • The Vortex Tube provides a simple, reliable, and environmentally friendly cooling method, requiring no electricity and no refrigerants, making it an efficient and practical cooling solution for a wide range of industrial applications.

Specifications

VORTEX TUBES

Model

Inlet Pressure

Air Consumption

Cooling Capacity

PSIG

BAR

SCFM

SLPM (ℓ/min)

Btu/hr.

Kcal/h

SMVT10008M/-HM

100

7

8

220

580

146

SMVT10010M/-HM

100

7

10

280

600

151

SMVT10015M/-HM

100

7

15

420

1100

277

SMVT10025M/-HM

100

7

25

700

2500

629

SMVT10035M/-HM

100

7

35

990

3500

881

※ Based on an inlet temperature of 21.1°C (70°F)

the flow rates in the table above are based on a pressure of 7 bar of supplied compressed air, and the flow rates will change as the pressure changes.

Dimensions

MEGA VORTEX TUBES

Specifications

Model

Inlet Pressure

Air Consumption

Cooling Capacity

PSIG

BAR

SCFM

SLPM (ℓ/min)

Btu/hr.

Kcal/h

SMVT10050M

100

7

50

1,400

5000

1,260

SMVT10060M

100

7

60

1,690

6000

1,512

※ Based on an inlet temperature of 21.1°C (70°F)

the flow rates in the table above are based on a pressure of 7 bar of supplied compressed air, and the flow rates will change as the pressure changes

Dimensions

Model Nomenclature

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
Vortex Tube SMVT10008M/-HM

Vortex Tube SMVT10008M/-HM

$0.00

Vortex Tube SMVT10008M/-HM: overview and buying guide

The Vortex Tube SMVT10008M/-HM (model SMVT10008M/-HM) is made by SEYANG MECHATRONICS and listed in our fa (factory automation) range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Vortex Tube SMVT10008M/-HM cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Vortex Tube SMVT10008M/-HM to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine SEYANG MECHATRONICS product?

We purchase directly from SEYANG MECHATRONICS or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

Vortex Tube

Key Features

  • A Vortex Tube is a device that separates a stream of compressed air (approximately 3–9.9 kgf/cm², 2–9.9 bar) into two distinct air streams—cold air and hot air—through an internal energy separation process.
    This mechanism enables localized cooling (Local Cooling) without the use of electrical power or refrigerants, making it an environmentally friendly cooling solution.

  • The device features a simple and robust design with no moving or rotating parts, which minimizes maintenance requirements while ensuring stable and highly reliable operation.

  • In addition, a Vortex Tube can generate instant cold air using only compressed air, eliminating the need for electrical power supply or complex cooling systems. For this reason, it is widely used as an efficient cooling solution in industrial environments, laboratories, and automation systems where localized cooling is required.
    Typical applications include:
    - Cooling of industrial equipment and control panels
    - Cooling in machining processes
    - Protection of electronic equipment and sensors
    - Localized cooling for laboratory instruments
    - Cooling of automation equipment and production lines

  • The Vortex Tube provides a simple, reliable, and environmentally friendly cooling method, requiring no electricity and no refrigerants, making it an efficient and practical cooling solution for a wide range of industrial applications.

Specifications

VORTEX TUBES

Model

Inlet Pressure

Air Consumption

Cooling Capacity

PSIG

BAR

SCFM

SLPM (ℓ/min)

Btu/hr.

Kcal/h

SMVT10008M/-HM

100

7

8

220

580

146

SMVT10010M/-HM

100

7

10

280

600

151

SMVT10015M/-HM

100

7

15

420

1100

277

SMVT10025M/-HM

100

7

25

700

2500

629

SMVT10035M/-HM

100

7

35

990

3500

881

※ Based on an inlet temperature of 21.1°C (70°F)

the flow rates in the table above are based on a pressure of 7 bar of supplied compressed air, and the flow rates will change as the pressure changes.

Dimensions

MEGA VORTEX TUBES

Specifications

Model

Inlet Pressure

Air Consumption

Cooling Capacity

PSIG

BAR

SCFM

SLPM (ℓ/min)

Btu/hr.

Kcal/h

SMVT10050M

100

7

50

1,400

5000

1,260

SMVT10060M

100

7

60

1,690

6000

1,512

※ Based on an inlet temperature of 21.1°C (70°F)

the flow rates in the table above are based on a pressure of 7 bar of supplied compressed air, and the flow rates will change as the pressure changes

Dimensions

Model Nomenclature

Detailed specification sheets are shown in the product images.

Catalogues