Vortex Tube SMVT10008M/-HM
Vortex Tube
Key Features
A Vortex Tube is a device that separates a stream of compressed air (approximately 3–9.9 kgf/cm², 2–9.9 bar) into two distinct air streams—cold air and hot air—through an internal energy separation process.
This mechanism enables localized cooling (Local Cooling) without the use of electrical power or refrigerants, making it an environmentally friendly cooling solution.The device features a simple and robust design with no moving or rotating parts, which minimizes maintenance requirements while ensuring stable and highly reliable operation.
In addition, a Vortex Tube can generate instant cold air using only compressed air, eliminating the need for electrical power supply or complex cooling systems. For this reason, it is widely used as an efficient cooling solution in industrial environments, laboratories, and automation systems where localized cooling is required.
Typical applications include:
- Cooling of industrial equipment and control panels
- Cooling in machining processes
- Protection of electronic equipment and sensors
- Localized cooling for laboratory instruments
- Cooling of automation equipment and production linesThe Vortex Tube provides a simple, reliable, and environmentally friendly cooling method, requiring no electricity and no refrigerants, making it an efficient and practical cooling solution for a wide range of industrial applications.
Specifications
VORTEX TUBES
Model |
Inlet Pressure |
Air Consumption |
Cooling Capacity |
|||
|---|---|---|---|---|---|---|
PSIG |
BAR |
SCFM |
SLPM (ℓ/min) |
Btu/hr. |
Kcal/h |
|
SMVT10008M/-HM |
100 |
7 |
8 |
220 |
580 |
146 |
SMVT10010M/-HM |
100 |
7 |
10 |
280 |
600 |
151 |
SMVT10015M/-HM |
100 |
7 |
15 |
420 |
1100 |
277 |
SMVT10025M/-HM |
100 |
7 |
25 |
700 |
2500 |
629 |
SMVT10035M/-HM |
100 |
7 |
35 |
990 |
3500 |
881 |
※ Based on an inlet temperature of 21.1°C (70°F)
the flow rates in the table above are based on a pressure of 7 bar of supplied compressed air, and the flow rates will change as the pressure changes.
Dimensions
MEGA VORTEX TUBES
Specifications
Model |
Inlet Pressure |
Air Consumption |
Cooling Capacity |
|||
|---|---|---|---|---|---|---|
PSIG |
BAR |
SCFM |
SLPM (ℓ/min) |
Btu/hr. |
Kcal/h |
|
SMVT10050M |
100 |
7 |
50 |
1,400 |
5000 |
1,260 |
SMVT10060M |
100 |
7 |
60 |
1,690 |
6000 |
1,512 |
※ Based on an inlet temperature of 21.1°C (70°F)
the flow rates in the table above are based on a pressure of 7 bar of supplied compressed air, and the flow rates will change as the pressure changes
Dimensions
Model Nomenclature
Detailed specification sheets are shown in the product images.
Catalogues
Vortex Tube SMVT10008M/-HM
Vortex Tube SMVT10008M/-HM: overview and buying guide
The Vortex Tube SMVT10008M/-HM (model SMVT10008M/-HM) is made by SEYANG MECHATRONICS and listed in our fa (factory automation) range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Vortex Tube SMVT10008M/-HM cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Vortex Tube SMVT10008M/-HM to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine SEYANG MECHATRONICS product?
We purchase directly from SEYANG MECHATRONICS or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Vortex Tube
Key Features
A Vortex Tube is a device that separates a stream of compressed air (approximately 3–9.9 kgf/cm², 2–9.9 bar) into two distinct air streams—cold air and hot air—through an internal energy separation process.
This mechanism enables localized cooling (Local Cooling) without the use of electrical power or refrigerants, making it an environmentally friendly cooling solution.The device features a simple and robust design with no moving or rotating parts, which minimizes maintenance requirements while ensuring stable and highly reliable operation.
In addition, a Vortex Tube can generate instant cold air using only compressed air, eliminating the need for electrical power supply or complex cooling systems. For this reason, it is widely used as an efficient cooling solution in industrial environments, laboratories, and automation systems where localized cooling is required.
Typical applications include:
- Cooling of industrial equipment and control panels
- Cooling in machining processes
- Protection of electronic equipment and sensors
- Localized cooling for laboratory instruments
- Cooling of automation equipment and production linesThe Vortex Tube provides a simple, reliable, and environmentally friendly cooling method, requiring no electricity and no refrigerants, making it an efficient and practical cooling solution for a wide range of industrial applications.
Specifications
VORTEX TUBES
Model |
Inlet Pressure |
Air Consumption |
Cooling Capacity |
|||
|---|---|---|---|---|---|---|
PSIG |
BAR |
SCFM |
SLPM (ℓ/min) |
Btu/hr. |
Kcal/h |
|
SMVT10008M/-HM |
100 |
7 |
8 |
220 |
580 |
146 |
SMVT10010M/-HM |
100 |
7 |
10 |
280 |
600 |
151 |
SMVT10015M/-HM |
100 |
7 |
15 |
420 |
1100 |
277 |
SMVT10025M/-HM |
100 |
7 |
25 |
700 |
2500 |
629 |
SMVT10035M/-HM |
100 |
7 |
35 |
990 |
3500 |
881 |
※ Based on an inlet temperature of 21.1°C (70°F)
the flow rates in the table above are based on a pressure of 7 bar of supplied compressed air, and the flow rates will change as the pressure changes.
Dimensions
MEGA VORTEX TUBES
Specifications
Model |
Inlet Pressure |
Air Consumption |
Cooling Capacity |
|||
|---|---|---|---|---|---|---|
PSIG |
BAR |
SCFM |
SLPM (ℓ/min) |
Btu/hr. |
Kcal/h |
|
SMVT10050M |
100 |
7 |
50 |
1,400 |
5000 |
1,260 |
SMVT10060M |
100 |
7 |
60 |
1,690 |
6000 |
1,512 |
※ Based on an inlet temperature of 21.1°C (70°F)
the flow rates in the table above are based on a pressure of 7 bar of supplied compressed air, and the flow rates will change as the pressure changes
Dimensions
Model Nomenclature
Detailed specification sheets are shown in the product images.