{"product_id":"venturi-tube-130022","title":"Venturi Tube HVT Series","description":"\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eHVT Series has been designed to gain the best performance for flow measurement on the basis of rich experience through the designing of several differential pressure flow meters in compliance with the standard of ISO 5167.\u003c\/p\u003e \u003cp\u003eA lot of manufacturers are producing the venturi tube but HITROL is continuously supplying this flow element with high quality on the basis of the continuous R\u0026amp;D and technical innovation through the improvement of the technic for flow measurement.\u003c\/p\u003e \u003cp\u003eHVT Series is a venturi tube flow element which measures a differential pressure occurred by a reducing of cross sectional area between inlet and throat section and it secures a stable discharge coefficient.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e■\u003c\/strong\u003e Discharge Coefficient (C)\u003c\/p\u003e \u003cp\u003eHVT Series can obtain an accuracy of ±0.5% ~ ±1.0% by performing of calibration in liquid flow calibration system.\u003c\/p\u003e \u003cp\u003eAs below graph, the discharge coefficient of flow element can be stably measured at any pipe Reynolds number greater than 75,000.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDesign and Manufacturing Standard\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eHitrol is designing and manufacturing the Venturi Tube in full compliance with standards of ISO 5167 and ASME MFC-3.\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e Fabricated Venturi Type Available in size between 3\" and 144\" \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Machined Screw Type Available in size  4\" and smaller \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Machined Weld-on Type Available in size 6\" and smaller \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Machined Flange Type Available in size 6\" and smaller \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eNo Effect by Downstream Disturbers\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eHVT Series is not affected on the basic measurement accuracy by any disturbers such as elbow, tee's, valves, increasers and reducer that are installed on downstream. However, measurement accuracy of other flow elements is more affected by these disturbers on downstream than HVT Series.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eEffect by Upstream Disturbers\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eEffect on the measurement accuracy by various upstream disturbers is well known and is as below graph.\u003c\/p\u003e \u003cp\u003e■ General effect by disturbers.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eISO 5167\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eRequired Straight Pipe Length\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e■ Values expressed as multiples of internal diameter, D\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003ePressure Taps Orientation\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDimension Table for Water Measurement (For Reference)\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eThe following data is for reference only. HVT Series can measure flow rate of gas, liquid and steam in a wide range of pipe line size and beta Ratio. Contact HITROL for more information.\u003c\/p\u003e \u003cp\u003e■ The data contained in this chart is based on reference values of 68℉(20℃) Water Producing 100inches (2540mm) of differential pressure.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDimension Table for Water Measurement (For Reference)\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e■ The data contained in this chart is based on reference values of 68℉(20℃) Water Producing 100inches (2540mm) of differential pressure.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-facab1352f1ad604.pdf\" target=\"_blank\" rel=\"noopener\"\u003e카탈로그-하이트롤-유량계-벤츄리 튜브-HVT 시리즈\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"HITROL","offers":[{"title":"Default Title","offer_id":58446482276692,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/hitrol_130022_cgogzs.jpg?v=1795190981","url":"https:\/\/premiumemart.com\/products\/venturi-tube-130022","provider":"Premium Emart","version":"1.0","type":"link"}