APPLICATION

Internal wiring for electric and electric appliance (1 AC 300/500V)

RATING

VCTFK 70℃ 300/300V

VCTF 70℃ 300/500V

HVCTF 90C 300/500V

CERTIFICATE

Korea Industrial Standards (Cert No. 08-0125)

Safety Certification for Electric and Electronic Appliance

CORE IDENIFICATION

No. of Cores

Color

2 Core

Sky Blue, Brown

3 Core

Green/Yellow, Sky Blue, Brown or Sky Blue, Black, Brown

4 Core

Green/Yellow, Sky Blue, Brown or Sky Blue, Black, Brown, Black or Brown

Standard Size

Symbol

Conductor

insulation

Thickness
(mm)

Sheath

Thickness

(mm

Mean Overall

Diameter

Conductor

Resistance at 20℃

Insulation

Resistance at

Norminal
Sectional
Area
(㎟)

Conductor
Class

Maximum
Diameter
of Wire
(mm)

Approx.
Diameter
(mm)

Lower
Limit
(mm)

Upper
Limit
(mm)

Copper
(Ω/km)

Tin-coated
Copper
(Ω /km)

70℃
(ΜΩ/km)

90℃
(ΜΩ/km)

60227 KS

IEC 53

300/500V

70℃

2X0.75

5

0.18

1.1

0.6

0.8

5.7

7.2

26.0

26.7

0.011

-

2X1.0

0.18

1.3

0.6

0.8

5.9

7.5

19.5

20.0

0.010

-

2X1.5

0.26

1.6

0.7

0.8

6.8

8.6

13.3

13.7

0.010

-

2X2.5

0.26

2.1

0.8

1.0

8.4

10.6

7,98

8,21

0,009

-

3X0.75

5

0.18

1.1

0.6

0.8

6.0

7.6

26.0

26.7

0.011

-

3X1.0

0.18

1.3

0.6

0.8

6.3

8.0

19.5

20.0

0.010

-

3X1.5

0.26

1.6

0.7

0.9

7.4

9.4

13.3

13,7

0,010

-

3X2.5

0.26

2.1

0.8

1.0

9.2

11.4

7,98

8.21

0.009

-

4X0.75

5

0.18

1.1

0.6

0.8

6.6

8.3

26.0

26.7

0.011

-

4X1.0

0.18

1.3

0.6

0.9

7.1

9.0

19.5

20.0

0.010

-

4X1.5

0.26

1.6

0.7

1.0

8.4

10.5

13.3

13.7

0.010

-

4X2.5

0.26

2.1

0.8

1.1

10.1

12.5

7.98

8.21

0.009

-

2X0.75

5

0.18

1.1

0.6

0.8

3.7X6.0

4.5X7.2

26.0

26.7

0.011

-

Detailed specification sheets are shown in the product images.

Error product group when enable variant picker

Availability: In stock
Categories: Electronic
VCTFK & VCTF & HVCTF

VCTFK & VCTF & HVCTF

$0.00

VCTFK & VCTF & HVCTF: overview and buying guide

The VCTFK & VCTF & HVCTF is made by DAECHANG ELECCOM and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the VCTFK & VCTF & HVCTF cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the VCTFK & VCTF & HVCTF to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine DAECHANG ELECCOM product?

We purchase directly from DAECHANG ELECCOM or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

VCTFK & VCTF & HVCTF

APPLICATION

Internal wiring for electric and electric appliance (1 AC 300/500V)

RATING

VCTFK 70℃ 300/300V

VCTF 70℃ 300/500V

HVCTF 90C 300/500V

CERTIFICATE

Korea Industrial Standards (Cert No. 08-0125)

Safety Certification for Electric and Electronic Appliance

CORE IDENIFICATION

No. of Cores

Color

2 Core

Sky Blue, Brown

3 Core

Green/Yellow, Sky Blue, Brown or Sky Blue, Black, Brown

4 Core

Green/Yellow, Sky Blue, Brown or Sky Blue, Black, Brown, Black or Brown

Standard Size

Symbol

Conductor

insulation

Thickness
(mm)

Sheath

Thickness

(mm

Mean Overall

Diameter

Conductor

Resistance at 20℃

Insulation

Resistance at

Norminal
Sectional
Area
(㎟)

Conductor
Class

Maximum
Diameter
of Wire
(mm)

Approx.
Diameter
(mm)

Lower
Limit
(mm)

Upper
Limit
(mm)

Copper
(Ω/km)

Tin-coated
Copper
(Ω /km)

70℃
(ΜΩ/km)

90℃
(ΜΩ/km)

60227 KS

IEC 53

300/500V

70℃

2X0.75

5

0.18

1.1

0.6

0.8

5.7

7.2

26.0

26.7

0.011

-

2X1.0

0.18

1.3

0.6

0.8

5.9

7.5

19.5

20.0

0.010

-

2X1.5

0.26

1.6

0.7

0.8

6.8

8.6

13.3

13.7

0.010

-

2X2.5

0.26

2.1

0.8

1.0

8.4

10.6

7,98

8,21

0,009

-

3X0.75

5

0.18

1.1

0.6

0.8

6.0

7.6

26.0

26.7

0.011

-

3X1.0

0.18

1.3

0.6

0.8

6.3

8.0

19.5

20.0

0.010

-

3X1.5

0.26

1.6

0.7

0.9

7.4

9.4

13.3

13,7

0,010

-

3X2.5

0.26

2.1

0.8

1.0

9.2

11.4

7,98

8.21

0.009

-

4X0.75

5

0.18

1.1

0.6

0.8

6.6

8.3

26.0

26.7

0.011

-

4X1.0

0.18

1.3

0.6

0.9

7.1

9.0

19.5

20.0

0.010

-

4X1.5

0.26

1.6

0.7

1.0

8.4

10.5

13.3

13.7

0.010

-

4X2.5

0.26

2.1

0.8

1.1

10.1

12.5

7.98

8.21

0.009

-

2X0.75

5

0.18

1.1

0.6

0.8

3.7X6.0

4.5X7.2

26.0

26.7

0.011

-

Detailed specification sheets are shown in the product images.