Vanstone Type Thermowell A6400
Service intended
Vanstone type thermowell is produced without any welding process by processing the whole round bar. Since it does not involve any welding process, it is used when high pressure, high velocity fluid and corrosive process media such as penetrating gas exist, and serving to isolate and protect from any leakage. The required flange is not standard and can be provided as an optional extra.
Standard features
| Selection of thermowell | ■ Material In general, the thermowell material chosen for the installation is governed mainly by the corrosion condition the thermowell will face. Recommended material for various services are given in the corrosion table. Occasionally, the material consideration is one of strength rather than corrosion. For example, a stainless steel thermowell may be required for a high pressure water service where otherwise a brass thermowell woule be satisfactory from a corrosion standpoint. ■ Insertion The distance from the end of the well to the underside of the thread or other connection means (Designated as "U") is the insertion length. ■ Bore size Almost any installation uses several type of temperature measuring instruments. The selection of a standard bore diameter can produce extreme flexibility within the plant. ■ Tapered or straight type Tapered type thermowells provide greater stiffness for the same sensitivity. The higher strength to weight ratio gives these thermowells higher natural frequency than for equivalent length straight type thermowells, thus permitting operation at higher fluid velocity. ■ Option Wake frequency calculations in accordance with ASME PTC 19.3 WISE Inc. offers this as an engineering service. ■ Standard "T" length Well size 1½" or DN40 : 40 mm 2" or DN50 : 45 mm |
© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Catalogues
Vanstone Type Thermowell A6400
Vanstone Type Thermowell A6400: overview and buying guide
The Vanstone Type Thermowell A6400 (model A6400) is made by WISE CONTROL and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Vanstone Type Thermowell A6400 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Vanstone Type Thermowell A6400 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine WISE CONTROL product?
We purchase directly from WISE CONTROL or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Service intended
Vanstone type thermowell is produced without any welding process by processing the whole round bar. Since it does not involve any welding process, it is used when high pressure, high velocity fluid and corrosive process media such as penetrating gas exist, and serving to isolate and protect from any leakage. The required flange is not standard and can be provided as an optional extra.
Standard features
| Selection of thermowell | ■ Material In general, the thermowell material chosen for the installation is governed mainly by the corrosion condition the thermowell will face. Recommended material for various services are given in the corrosion table. Occasionally, the material consideration is one of strength rather than corrosion. For example, a stainless steel thermowell may be required for a high pressure water service where otherwise a brass thermowell woule be satisfactory from a corrosion standpoint. ■ Insertion The distance from the end of the well to the underside of the thread or other connection means (Designated as "U") is the insertion length. ■ Bore size Almost any installation uses several type of temperature measuring instruments. The selection of a standard bore diameter can produce extreme flexibility within the plant. ■ Tapered or straight type Tapered type thermowells provide greater stiffness for the same sensitivity. The higher strength to weight ratio gives these thermowells higher natural frequency than for equivalent length straight type thermowells, thus permitting operation at higher fluid velocity. ■ Option Wake frequency calculations in accordance with ASME PTC 19.3 WISE Inc. offers this as an engineering service. ■ Standard "T" length Well size 1½" or DN40 : 40 mm 2" or DN50 : 45 mm |
© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
