{"product_id":"uv-vis-nir-spectrometers-137171","title":"UV-Vis-NIR Spectrometers OES-Star","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eUV-VIS-NIR Spectrometer\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eHoriba’s OEM division, a major supplier of OES solutions, has developed a high end OES Spectrometer with a proprietary optical configuration for broad coverage (185-1050 nm) and high resolution. The OES-Star is available with a selection of three UV-VIS-NIR Back-Illuminated (B.I.) sensors, one TE-Cooled and two uncooled CCD detectors. This unique OES system features an optical design that provides a high peak symmetry across a very broad spectral range combined with high spectral resolution better than 1 nm, at an unmatched aperture of F\/2.3.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFor OEM Industrial Applications\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eㆍ Optical Emission Spectrometry\u003cbr\u003eㆍ Reflectometry\u003cbr\u003eㆍ Process and Quality Control\u003cbr\u003eㆍ Examples :\u003cbr\u003e - Endpoint Detection\u003cbr\u003e - Plasma Monitoring\u003cbr\u003e - Semiconductor Wafer Inspection\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cp\u003eㆍ Optical emission spectrometry (OES)\u003cbr\u003eㆍ Unmatched long term stability and excellent wavelength accuracy\u003cbr\u003eㆍ USB2 Ethernet and EtherCAT interface\u003cbr\u003eㆍ High spectral resolution combined with high throughput\u003cbr\u003eㆍ Broad wavelength coverage from UV to NIR \u003cbr\u003eㆍ Multiple B.I. CCD options cooled\/uncooled with high dynamic range \u003cbr\u003eㆍ CMOS sensor option with electronic shutter and ultra high spectral rate\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFlat resolution and dispersion across the entire spectral range (185 -1050 nm) combined with excellent peak symmetry\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eThis OES-Star is featuring a tall CCD with built in round-to-line (RTL) fiber converter to maximize light collection and therefore the system throughput. Input fiber with a core of 1 mm or smaller can be used. However to take advantage of the tall detector and RTL, larger core fibers are recommended.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eBuilt-in round-to-line (RTL) converter boosts throughput when combined with a large core diameter fiber and our tall CCD (S13241-1108S)\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eQuantum Efficiency Plot\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eOEM Spectrometer Selection Guide\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003eGeneral Spectrometer Specifications*\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Spectral Coverage \u003c\/td\u003e \u003ctd\u003e185 – 1050 nm (2048 horizontal pixel format with 14 µm pixel size)\u003cbr\u003e200 – 1050 nm (2048 horizontal pixel format with 12 µm pixel size)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Spectrometer Input \u003c\/td\u003e \u003ctd\u003eSMA (standard), other input types available upon request\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Spectral Resolution \u003c\/td\u003e \u003ctd\u003e\u0026lt;1 nm with 22 µm slit with very high symmetry across broad spectral range\u003cbr\u003e(flexible based on customer’s need)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Average Spectral Dispersion \u003c\/td\u003e \u003ctd\u003e34.6 nm\/mm, 0.484 nm\/pixel (14 µm pixel size), 0.41 nm\/pixel (12 µm pixel size)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Focal Length \u003c\/td\u003e \u003ctd\u003e116 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e F\/# \u003c\/td\u003e \u003ctd\u003eF\/2.3 \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Wavelength Accuracy \u003c\/td\u003e \u003ctd\u003e\u0026lt; +\/- 0.1 nm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Stray Light \u003c\/td\u003e \u003ctd\u003e\u0026lt; 0.1%*\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Software \u003c\/td\u003e \u003ctd\u003e LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration) \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable class=\"pem-spec\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eCCD Detector Model\u003c\/th\u003e \u003cth\u003eCooled BI High-end CCD\u003cbr\u003ewith best dynamic range\u003cbr\u003e(S13241-1108S)\u003c\/th\u003e \u003cth\u003eBI CCD Middle Grade\u003cbr\u003e(S14660-2048N)\u003c\/th\u003e \u003cth\u003eBI CCD cost effective\u003cbr\u003e(S11071-1106N)\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eCCD Sensor Format\u003c\/td\u003e \u003ctd\u003e2048 x 256\u003c\/td\u003e \u003ctd\u003e2048 x 192\u003c\/td\u003e \u003ctd\u003e2048 x 70\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCCD Pixel Size\u003c\/td\u003e \u003ctd\u003e12 x 12 μm\u003c\/td\u003e \u003ctd\u003e14 x 14 μm\u003c\/td\u003e \u003ctd\u003e14 x 14 μm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eImage Size\u003c\/td\u003e \u003ctd\u003e24.5 x 3.0 mm\u003c\/td\u003e \u003ctd\u003e28.6 x 2.68 mm\u003c\/td\u003e \u003ctd\u003e28.7 x 1.0 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCCD QE at 20°C\u003c\/td\u003e \u003ctd\u003e90% or higher at the peak\u003c\/td\u003e \u003ctd\u003eHigh sensitivity over a\u003cbr\u003ewide spectral range\u003c\/td\u003e \u003ctd\u003e\u0026gt; 75% for 450 - 750 nm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDeep Thermoelectric Cooling\u003c\/td\u003e \u003ctd\u003e-5º C\u003c\/td\u003e \u003ctd\u003eNon-cooled\u003c\/td\u003e \u003ctd\u003eNon-cooled\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFull Well Capacity\u003c\/td\u003e \u003ctd\u003e500,000 e¯\/pixel (typical)\u003c\/td\u003e \u003ctd\u003e200,000 e¯\/pixel (typical)\u003c\/td\u003e \u003ctd\u003e\u0026gt;200,000 e¯\/pixel (typical)\u003cbr\u003e\u0026gt;175,000 e¯\/pixel (minimum)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eReadout Noise\u003c\/td\u003e \u003ctd\u003e50 e¯ (typical)\u003cbr\u003e(@ 1.5MHz sampling)\u003c\/td\u003e \u003ctd\u003e40 e¯ (typical)\u003cbr\u003e50 e¯ (maximum)\u003c\/td\u003e \u003ctd\u003e35 e¯ (typical)\u003cbr\u003e45 e¯ (maximum)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDigitization\u003c\/td\u003e \u003ctd\u003e16-bit ADC\u003c\/td\u003e \u003ctd\u003e16-bit ADC\u003c\/td\u003e \u003ctd\u003e16-bit ADC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDynamic range (FW\/RN)\u003c\/td\u003e \u003ctd\u003e10000:1\u003c\/td\u003e \u003ctd\u003e5000:1\u003c\/td\u003e \u003ctd\u003e5700:1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNon-linearity\u003cbr\u003e(measured on each system)\u003c\/td\u003e \u003ctd\u003e\u0026lt;1.8% (maximum) at low gain\u003cbr\u003e\u0026lt;0.9% (maximum) at high gain\u003c\/td\u003e \u003ctd\u003e\u0026lt;0.1% (corrected)\u003c\/td\u003e \u003ctd\u003e\u0026lt;0.1% (corrected)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDark Current\u003c\/td\u003e \u003ctd\u003e1.5 e-\/pixel\/s (typical) @-5° C\u003cbr\u003e15 e¯\/pixel\/s (maximum)\u003c\/td\u003e \u003ctd\u003e50 e¯\/pixel\/s (typical) @ 20° C\u003cbr\u003e500 e¯\/pixel\/s (maximum)\u003c\/td\u003e \u003ctd\u003e50 e¯\/pixel\/s (typical) @ 20° C\u003cbr\u003e500 e¯\/pixel\/s (maximum)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnvironmental Conditions\u003c\/td\u003e \u003ctd colspan=\"3\" rowspan=\"1\"\u003eOperating temperature 0° C to 40° C ambient\u003cbr\u003eRelative humidity \u0026lt;70% (non-condensing)\u003cbr\u003eStorage temperature -20° C to 50° C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Requirements\u003cbr\u003eAC\/DC Power Supply (provided)\u003c\/td\u003e \u003ctd colspan=\"3\" rowspan=\"1\"\u003e90-264 VAC, 47–63 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e*Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW™ license is needed to run our acquisition software.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMechanical Drawings\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-52f29f1c0f9c11cb.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-Horiba-UV-Vis-NIR Spectrometers-OES-Star\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-e52154b23264429e.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDrawing-Horiba-UV-Vis-NIR Spectrometers-OES-Star\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HORIBA","offers":[{"title":"Default Title","offer_id":58446674231636,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/0632d54a-f74a-4e34-adab-369bfd918e89.jpg?v=1795191436","url":"https:\/\/premiumemart.com\/products\/uv-vis-nir-spectrometers-137171","provider":"Premium Emart","version":"1.0","type":"link"}