UV-Vis-NIR Spectrometers OES-Star
Overview
UV-VIS-NIR Spectrometer
Horiba’s OEM division, a major supplier of OES solutions, has developed a high end OES Spectrometer with a proprietary optical configuration for broad coverage (185-1050 nm) and high resolution. The OES-Star is available with a selection of three UV-VIS-NIR Back-Illuminated (B.I.) sensors, one TE-Cooled and two uncooled CCD detectors. This unique OES system features an optical design that provides a high peak symmetry across a very broad spectral range combined with high spectral resolution better than 1 nm, at an unmatched aperture of F/2.3.
For OEM Industrial Applications
ㆍ Optical Emission Spectrometry
ㆍ Reflectometry
ㆍ Process and Quality Control
ㆍ Examples :
- Endpoint Detection
- Plasma Monitoring
- Semiconductor Wafer Inspection
Features
ㆍ Optical emission spectrometry (OES)
ㆍ Unmatched long term stability and excellent wavelength accuracy
ㆍ USB2 Ethernet and EtherCAT interface
ㆍ High spectral resolution combined with high throughput
ㆍ Broad wavelength coverage from UV to NIR
ㆍ Multiple B.I. CCD options cooled/uncooled with high dynamic range
ㆍ CMOS sensor option with electronic shutter and ultra high spectral rate
Flat resolution and dispersion across the entire spectral range (185 -1050 nm) combined with excellent peak symmetry
This OES-Star is featuring a tall CCD with built in round-to-line (RTL) fiber converter to maximize light collection and therefore the system throughput. Input fiber with a core of 1 mm or smaller can be used. However to take advantage of the tall detector and RTL, larger core fibers are recommended.
Built-in round-to-line (RTL) converter boosts throughput when combined with a large core diameter fiber and our tall CCD (S13241-1108S)
Quantum Efficiency Plot
OEM Spectrometer Selection Guide
Specifications
| General Spectrometer Specifications* | |
|---|---|
| Spectral Coverage | 185 – 1050 nm (2048 horizontal pixel format with 14 µm pixel size) 200 – 1050 nm (2048 horizontal pixel format with 12 µm pixel size) |
| Spectrometer Input | SMA (standard), other input types available upon request |
| Spectral Resolution | <1 nm with 22 µm slit with very high symmetry across broad spectral range (flexible based on customer’s need) |
| Average Spectral Dispersion | 34.6 nm/mm, 0.484 nm/pixel (14 µm pixel size), 0.41 nm/pixel (12 µm pixel size) |
| Focal Length | 116 mm |
| F/# | F/2.3 |
| Wavelength Accuracy | < +/- 0.1 nm |
| Stray Light | < 0.1%* |
| Software | LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration) |
| CCD Detector Model | Cooled BI High-end CCD with best dynamic range (S13241-1108S) | BI CCD Middle Grade (S14660-2048N) | BI CCD cost effective (S11071-1106N) |
|---|---|---|---|
| CCD Sensor Format | 2048 x 256 | 2048 x 192 | 2048 x 70 |
| CCD Pixel Size | 12 x 12 μm | 14 x 14 μm | 14 x 14 μm |
| Image Size | 24.5 x 3.0 mm | 28.6 x 2.68 mm | 28.7 x 1.0 mm |
| CCD QE at 20°C | 90% or higher at the peak | High sensitivity over a wide spectral range | > 75% for 450 - 750 nm |
| Deep Thermoelectric Cooling | -5º C | Non-cooled | Non-cooled |
| Full Well Capacity | 500,000 e¯/pixel (typical) | 200,000 e¯/pixel (typical) | >200,000 e¯/pixel (typical) >175,000 e¯/pixel (minimum) |
| Readout Noise | 50 e¯ (typical) (@ 1.5MHz sampling) | 40 e¯ (typical) 50 e¯ (maximum) | 35 e¯ (typical) 45 e¯ (maximum) |
| Digitization | 16-bit ADC | 16-bit ADC | 16-bit ADC |
| Dynamic range (FW/RN) | 10000:1 | 5000:1 | 5700:1 |
| Non-linearity (measured on each system) | <1.8% (maximum) at low gain <0.9% (maximum) at high gain | <0.1% (corrected) | <0.1% (corrected) |
| Dark Current | 1.5 e-/pixel/s (typical) @-5° C 15 e¯/pixel/s (maximum) | 50 e¯/pixel/s (typical) @ 20° C 500 e¯/pixel/s (maximum) | 50 e¯/pixel/s (typical) @ 20° C 500 e¯/pixel/s (maximum) |
| Environmental Conditions | Operating temperature 0° C to 40° C ambient Relative humidity <70% (non-condensing) Storage temperature -20° C to 50° C | ||
| Power Requirements AC/DC Power Supply (provided) | 90-264 VAC, 47–63 Hz | ||
*Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW™ license is needed to run our acquisition software.
Mechanical Drawings
Detailed specification sheets are shown in the product images.
Catalogues
UV-Vis-NIR Spectrometers OES-Star
UV-Vis-NIR Spectrometers OES-Star: overview and buying guide
The UV-Vis-NIR Spectrometers OES-Star (model OES-Star) is made by HORIBA and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the UV-Vis-NIR Spectrometers OES-Star cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the UV-Vis-NIR Spectrometers OES-Star to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine HORIBA product?
We purchase directly from HORIBA or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Overview
UV-VIS-NIR Spectrometer
Horiba’s OEM division, a major supplier of OES solutions, has developed a high end OES Spectrometer with a proprietary optical configuration for broad coverage (185-1050 nm) and high resolution. The OES-Star is available with a selection of three UV-VIS-NIR Back-Illuminated (B.I.) sensors, one TE-Cooled and two uncooled CCD detectors. This unique OES system features an optical design that provides a high peak symmetry across a very broad spectral range combined with high spectral resolution better than 1 nm, at an unmatched aperture of F/2.3.
For OEM Industrial Applications
ㆍ Optical Emission Spectrometry
ㆍ Reflectometry
ㆍ Process and Quality Control
ㆍ Examples :
- Endpoint Detection
- Plasma Monitoring
- Semiconductor Wafer Inspection
Features
ㆍ Optical emission spectrometry (OES)
ㆍ Unmatched long term stability and excellent wavelength accuracy
ㆍ USB2 Ethernet and EtherCAT interface
ㆍ High spectral resolution combined with high throughput
ㆍ Broad wavelength coverage from UV to NIR
ㆍ Multiple B.I. CCD options cooled/uncooled with high dynamic range
ㆍ CMOS sensor option with electronic shutter and ultra high spectral rate
Flat resolution and dispersion across the entire spectral range (185 -1050 nm) combined with excellent peak symmetry
This OES-Star is featuring a tall CCD with built in round-to-line (RTL) fiber converter to maximize light collection and therefore the system throughput. Input fiber with a core of 1 mm or smaller can be used. However to take advantage of the tall detector and RTL, larger core fibers are recommended.
Built-in round-to-line (RTL) converter boosts throughput when combined with a large core diameter fiber and our tall CCD (S13241-1108S)
Quantum Efficiency Plot
OEM Spectrometer Selection Guide
Specifications
| General Spectrometer Specifications* | |
|---|---|
| Spectral Coverage | 185 – 1050 nm (2048 horizontal pixel format with 14 µm pixel size) 200 – 1050 nm (2048 horizontal pixel format with 12 µm pixel size) |
| Spectrometer Input | SMA (standard), other input types available upon request |
| Spectral Resolution | <1 nm with 22 µm slit with very high symmetry across broad spectral range (flexible based on customer’s need) |
| Average Spectral Dispersion | 34.6 nm/mm, 0.484 nm/pixel (14 µm pixel size), 0.41 nm/pixel (12 µm pixel size) |
| Focal Length | 116 mm |
| F/# | F/2.3 |
| Wavelength Accuracy | < +/- 0.1 nm |
| Stray Light | < 0.1%* |
| Software | LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration) |
| CCD Detector Model | Cooled BI High-end CCD with best dynamic range (S13241-1108S) | BI CCD Middle Grade (S14660-2048N) | BI CCD cost effective (S11071-1106N) |
|---|---|---|---|
| CCD Sensor Format | 2048 x 256 | 2048 x 192 | 2048 x 70 |
| CCD Pixel Size | 12 x 12 μm | 14 x 14 μm | 14 x 14 μm |
| Image Size | 24.5 x 3.0 mm | 28.6 x 2.68 mm | 28.7 x 1.0 mm |
| CCD QE at 20°C | 90% or higher at the peak | High sensitivity over a wide spectral range | > 75% for 450 - 750 nm |
| Deep Thermoelectric Cooling | -5º C | Non-cooled | Non-cooled |
| Full Well Capacity | 500,000 e¯/pixel (typical) | 200,000 e¯/pixel (typical) | >200,000 e¯/pixel (typical) >175,000 e¯/pixel (minimum) |
| Readout Noise | 50 e¯ (typical) (@ 1.5MHz sampling) | 40 e¯ (typical) 50 e¯ (maximum) | 35 e¯ (typical) 45 e¯ (maximum) |
| Digitization | 16-bit ADC | 16-bit ADC | 16-bit ADC |
| Dynamic range (FW/RN) | 10000:1 | 5000:1 | 5700:1 |
| Non-linearity (measured on each system) | <1.8% (maximum) at low gain <0.9% (maximum) at high gain | <0.1% (corrected) | <0.1% (corrected) |
| Dark Current | 1.5 e-/pixel/s (typical) @-5° C 15 e¯/pixel/s (maximum) | 50 e¯/pixel/s (typical) @ 20° C 500 e¯/pixel/s (maximum) | 50 e¯/pixel/s (typical) @ 20° C 500 e¯/pixel/s (maximum) |
| Environmental Conditions | Operating temperature 0° C to 40° C ambient Relative humidity <70% (non-condensing) Storage temperature -20° C to 50° C | ||
| Power Requirements AC/DC Power Supply (provided) | 90-264 VAC, 47–63 Hz | ||
*Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW™ license is needed to run our acquisition software.
Mechanical Drawings
Detailed specification sheets are shown in the product images.