{"product_id":"uv-vis-nir-spectrometers-137167","title":"UV-Vis-NIR Spectrometers VS70-HSR","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eHigh Spectral Rate and High Dynamic Range Miniature Spectrometers\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eVS70 is a high performance compact fiber coupled spectrometer system covering wide spectral range of 200 to 1050 nm. This OEM optical module is built around Horiba’s type-IV Aberration-Corrected Flat-Field Holographic Ion-Etched concave grating and is specially designed to easily adapt to a large variety of detectors and electronic drivers. This system is fitted with a custom variable order-sorting filter to eliminate higher orders.\u003c\/p\u003e \u003cp\u003eThe proprietary layout of the VS70 features a single-optics design for superior imaging, peak symmetry and resolution, sensitivity and low-stray light performance, for low-light applications (fluorescence, emission) and high-dynamic applications (absorbance, reflectance). \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFor OEM Industrial Applications\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eIdeal for industrial low-light applications such as fluorescence, emission, absorbance, and reflectance.\u003c\/p\u003e \u003cp\u003eExamples:\u003c\/p\u003e \u003cp\u003eㆍSemiconductor plasma monitoring\u003cbr\u003eㆍColorimetry\u003cbr\u003eㆍBlood and urine analysis\u003cbr\u003eㆍLiquid chromatography\u003cbr\u003eㆍFood moisture content analysis\u003cbr\u003eㆍFlow cytometry\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cp\u003eㆍHigh spectral resolution and system throughput\u003cbr\u003eㆍCompact size robustness and stability\u003cbr\u003eㆍHigh Spectral Rate (HSR)\u003cbr\u003eㆍHigh Dynamic Range (HDR)\u003cbr\u003eㆍWide spectral covrage from UV to NIR combined with ultra low stray light\u003cbr\u003eㆍHigh linearity (raw and linearity-correction\u003cbr\u003eㆍHighly customizable for various applications\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eOEM Spectrometer Selection Guide\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003eGeneral Spectrometer Specifications*\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Spectral Coverage \u003c\/td\u003e \u003ctd\u003eStandard: UV-VIS (200–860 nm) with 477 l\/mm grating, VIS (380–750 nm) with 582 l\/mm\u003cbr\u003egrating, UV-NIR (200–1050 nm) with double-blazed 365 l\/mm grating\u003cbr\u003eOn request other spectral ranges available; different mechanical integration might needed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Spectrometer Input \u003c\/td\u003e \u003ctd\u003eFiber coupled: FC or SMA; Free space: 12-25-37-50-62-75-100-125-150-200 μm slits, other options\u003cbr\u003eavailable upon request\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Spectral Resolution \u003c\/td\u003e \u003ctd\u003e2 nm for 365 l\/mm grating, 1 nm for 477 l\/mm grating, 0.8 nm for 582 l\/mm grating\u003cbr\u003e(25 μm slit for all)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAverage Spectral\u003cbr\u003eDispersion\u003c\/td\u003e \u003ctd\u003e30.9 nm\/mm for 365 l\/mm grating, 23.7 nm\/mm for 477 l\/mm grating\u003cbr\u003e16.3 nm\/mm for 582 l\/mm grating\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Focal Length \u003c\/td\u003e \u003ctd\u003e 70 mm \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOptions\u003c\/td\u003e \u003ctd\u003eSelection of high grade sensors: CMOS, B.I. CCD, PDA\u003cbr\u003eInput port: SMA, FC, free space, custom input\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e F\/# \u003c\/td\u003e \u003ctd\u003eF\/2.8\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStray-light Rejection\u003cbr\u003eTypical (Maximum)\u003c\/td\u003e \u003ctd\u003e0.01% (0.02%) for UV-VIS configuration with 300 μm tall CCD, measured at 700 nm\u003cbr\u003e(measured with broad bandpass 510 nm filter, 75 μm slit-width)\u003cbr\u003e\u0026gt; 2.4 AU linear range (5% variation) with caffeine 273 nm absorption peak in 10 mm cuvette\u003cbr\u003eand D\u003csub\u003e2\u003c\/sub\u003e lamp\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Wavelength Accuracy \u003c\/td\u003e \u003ctd\u003e0.2 nm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Software** \u003c\/td\u003e \u003ctd\u003e LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration) \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eDetector Options and Specifications*\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eLinear back-illuminated CCD with large active area and high sensitivity\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDetector Model\u003c\/td\u003e \u003ctd\u003eHamamatsu CCD sensor S11071 with high\u003cbr\u003espectral acquisition speed\u003c\/td\u003e \u003ctd\u003eHamamatsu CCD sensor S10420 with high\u003cbr\u003edynamic range\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSensor Format\u003c\/td\u003e \u003ctd\u003e2048 x 70 pixels, shorter version\u003cbr\u003eavailable on request\u003c\/td\u003e \u003ctd\u003e2048 x 70 pixels, shorter version\u003cbr\u003eavailable on request\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCCD Pixel Size\u003c\/td\u003e \u003ctd\u003e14 x 14 μm\u003c\/td\u003e \u003ctd\u003e14 x 14 μm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCCD Active Area\u003c\/td\u003e \u003ctd\u003e28.7 x 1 mm\u003c\/td\u003e \u003ctd\u003e28.7 x 1 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCCD QE\u003c\/td\u003e \u003ctd\u003e\u0026gt; 75% for 450-750 nm\u003c\/td\u003e \u003ctd\u003e\u0026gt; 75% for 450-750 nm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSensor Temperature\u003c\/td\u003e \u003ctd\u003eUncooled\u003c\/td\u003e \u003ctd\u003eUncooled\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMaximum Spectral Rate\u003c\/td\u003e \u003ctd\u003e760 spectra\/s\u003c\/td\u003e \u003ctd\u003e223 spectra\/s\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFull Well Capacity\u003c\/td\u003e \u003ctd\u003e\u0026gt;200,000 e¯ (typical); \u0026gt;175,000 e¯ (minimum)\u003c\/td\u003e \u003ctd\u003e\u0026gt;225,000 e¯ (sensitivity mode); \u0026gt;375,000 e¯\u003cbr\u003e(high full well mode)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eReadout Noise\u003c\/td\u003e \u003ctd\u003e35 e¯ (typical); 45 e¯ (maximum)\u003c\/td\u003e \u003ctd\u003e35 e¯ (typical) \u0026amp; 45 e¯ (maximum) in\u003cbr\u003esensitivity mode; 50 e¯ (typical) and\u003cbr\u003e75 e¯ (maximum) in high full well mode\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDigitization\u003c\/td\u003e \u003ctd\u003e16-bit\u003c\/td\u003e \u003ctd\u003e16-bit\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDynamic Range (FW\/RN)\u003c\/td\u003e \u003ctd\u003e6,000:1 (typical)\u003c\/td\u003e \u003ctd\u003e7,000:1 (typical) in sensitivity mode;\u003cbr\u003e5,500:1 (typical) in high FW mode\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNon-linearity (measured\u003cbr\u003eon each system)\u003c\/td\u003e \u003ctd\u003e\u0026lt; 0.4% (corrected)\u003c\/td\u003e \u003ctd\u003e\u0026lt; 0.4% (corrected)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDark current @ (25°C)\u003c\/td\u003e \u003ctd\u003e50 e-\/pix\/s (typical); 500 e-\/pix\/s (maximum)\u003c\/td\u003e \u003ctd\u003e7 e-\/pix\/s (typical); 70 e-\/pix\/s (maximum)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCommunication\u003c\/td\u003e \u003ctd\u003eUSB2\u003c\/td\u003e \u003ctd\u003eUSB2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnvironmental Conditions\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003eOperating temperature 15° C to 40° C ambient\u003cbr\u003eRelative humidity \u0026lt;70% (non-condensing)\u003cbr\u003eStorage temperature -25° C to 45° C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Requirements\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003eMolex connector (24 VDC)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e* HORIBA Instruments has a policy of continuous product development, and reserves the right to amend part numbers, descriptions and specifications without prior notice.\u003c\/p\u003e \u003cp\u003e**No LabVIEW™ license is needed to run our acquisition software.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eQuantum Efficiency\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMechanical Drawings\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-d0e6e2db6a08ad36.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-Horiba-UV-Vis-NIR Spectrometers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-235d14c55e09a145.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDrawing-Horiba-UV-Vis-NIR Spectrometers\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HORIBA","offers":[{"title":"Default Title","offer_id":58446672068948,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/a8569339-0d03-4d6b-8055-775597d4f038.jpg?v=1795191432","url":"https:\/\/premiumemart.com\/products\/uv-vis-nir-spectrometers-137167","provider":"Premium Emart","version":"1.0","type":"link"}