Format and Model

SUF

Operating principle

The AceSonic ultrasonic flowmeter is designed to measure the fluid velocity within a pipe using the ultrasonic transit time method.
The sensor is pipe-mounted, offering the advantage of easy installation and measurement.
The sensor in the AceSonic ultrasonic flowmeter performs the dual functions of an ultrasonic transmitter and receiver.
The sensor is fixed to the outer wall of the pipe at a specific distance.

The sensor can be installed using the V-method, where sound waves traverse the pipe twice; the W-method, where sound waves pass through the pipe four times; or the Z-method, where the sensor crosses from opposite ends of the pipe.

The pipe mounting method depends on the selected pipe and the characteristics of the fluid being measured.

The AceSonic ultrasonic flowmeter operates on the principle that two sensors repeatedly transmit and receive to measure the transit time difference, which varies according to the ultrasonic propagation speed within the fluid, thereby measuring the flow velocity and calculating the flow rate.

range

ㆍFlow velocity: 0 ~ ±10 m/s
ㆍM-type sensor applicable pipe size [Standard]: DN 50~700 mm
ㆍL-type sensor: Applicable pipe size DN 300-6000 mm
ㆍS-type sensor: Applicable pipe size DN 15-100 mm

temperature

ㆍStandard type: -30 ~ 90℃
ㆍHigh temperature type: -30 ~ 160℃

enter

characteristic

ㆍ Measurement possible without filters or filtration equipment as it is unaffected by suspended solids in the pipe.
ㆍ Digital cross-correlation technology.
ㆍ Easy maintenance as the sensor does not come into contact with the liquid.
ㆍ Easy installation with an external mounting design.
ㆍConvenient operation with an easy-to-use menu configuration.
ㆍ Applicable to various pipes with a single pair of sensors.
ㆍ Displays cumulative flow rate, instantaneous flow rate, flow velocity, and flow meter operating status.
ㆍ Pulse and frequency open collector output.

output of power

ㆍ4-20mA: Max 500 ohm, Accuracy: 0.1%
ㆍPulse Output: 1~9999Hz (From OCT), Flow Rate Output
ㆍRS485: MODBUS Communication
ㆍRelay Output
ㆍDisplay: LCD Backlight, Displays Total Flow Rate, Instantaneous Flow Rate, Flow Velocity

Power specifications

90-240VAC 50/60Hz ±10% @ 1.5W

apply

note

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
Categories: Test · Measurement
Ultrasonic Flowmeter SUF Series

Ultrasonic Flowmeter SUF Series

$0.00

Ultrasonic Flowmeter SUF Series: overview and buying guide

The Ultrasonic Flowmeter SUF Series (model SUF Series) is made by SEOJIN INSTECH and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Ultrasonic Flowmeter SUF Series cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Ultrasonic Flowmeter SUF Series to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine SEOJIN INSTECH product?

We purchase directly from SEOJIN INSTECH or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

 Ultrasonic Flowmeter

Format and Model

SUF

Operating principle

The AceSonic ultrasonic flowmeter is designed to measure the fluid velocity within a pipe using the ultrasonic transit time method.
The sensor is pipe-mounted, offering the advantage of easy installation and measurement.
The sensor in the AceSonic ultrasonic flowmeter performs the dual functions of an ultrasonic transmitter and receiver.
The sensor is fixed to the outer wall of the pipe at a specific distance.

The sensor can be installed using the V-method, where sound waves traverse the pipe twice; the W-method, where sound waves pass through the pipe four times; or the Z-method, where the sensor crosses from opposite ends of the pipe.

The pipe mounting method depends on the selected pipe and the characteristics of the fluid being measured.

The AceSonic ultrasonic flowmeter operates on the principle that two sensors repeatedly transmit and receive to measure the transit time difference, which varies according to the ultrasonic propagation speed within the fluid, thereby measuring the flow velocity and calculating the flow rate.

range

ㆍFlow velocity: 0 ~ ±10 m/s
ㆍM-type sensor applicable pipe size [Standard]: DN 50~700 mm
ㆍL-type sensor: Applicable pipe size DN 300-6000 mm
ㆍS-type sensor: Applicable pipe size DN 15-100 mm

temperature

ㆍStandard type: -30 ~ 90℃
ㆍHigh temperature type: -30 ~ 160℃

enter

characteristic

ㆍ Measurement possible without filters or filtration equipment as it is unaffected by suspended solids in the pipe.
ㆍ Digital cross-correlation technology.
ㆍ Easy maintenance as the sensor does not come into contact with the liquid.
ㆍ Easy installation with an external mounting design.
ㆍConvenient operation with an easy-to-use menu configuration.
ㆍ Applicable to various pipes with a single pair of sensors.
ㆍ Displays cumulative flow rate, instantaneous flow rate, flow velocity, and flow meter operating status.
ㆍ Pulse and frequency open collector output.

output of power

ㆍ4-20mA: Max 500 ohm, Accuracy: 0.1%
ㆍPulse Output: 1~9999Hz (From OCT), Flow Rate Output
ㆍRS485: MODBUS Communication
ㆍRelay Output
ㆍDisplay: LCD Backlight, Displays Total Flow Rate, Instantaneous Flow Rate, Flow Velocity

Power specifications

90-240VAC 50/60Hz ±10% @ 1.5W

apply

note

Detailed specification sheets are shown in the product images.