Thermal Mass Flow Sensor VA420
Thermal Mass Flow Sensor VA420
New
Thermal Mass Flow Sensor VA420
Thermal Mass Flow Sensor VA420

Thermal Mass Flow Sensor VA420

AVA 420 thermal mass flow sensor

Dimensions

Flow measuring ranges AVA 420

Connection

thread

Outer pope

diam.mm

Inner pipe

diam.mm

Measuring

range from to

L

L1

H

H1

A

R 1/2"

21.3

16.1

0.2 ... 90 m3/h

300

210

176.4

165.7

20

R3/4"

26.9

21.7

0.3 ... 170 m3/h

475

275

179.2

165.7

20

R 1"

33.7

27.3

0.5 ... 290 m3/h

475

275

182.6

165.7

25

R 11/2"

48.3

41.8

1.0 ... 550 m3/h

475*

275

189.9

165.7

25

R2"

60.3

53.1

2.0 ... 900 m3/h

475*

275

195.9

165.7

30

* Attention: Shortened inlet section! Please observe the recommended minimum inlet section [length = 15 x inner diameter] on site.

Order no.

Display

Thread

Direction

Medium

Description

0695 0421

AVA 420, flow sensor, inline type, DN 15

0695 0422

AVA 420, flow sensor, inline type, DN 20

0695 0423

AVA 420, flow sensor, inline type, DN 25

0695 0424

AVA 420, flow sensor, inline type, DN 40

0695 0425

AVA 420, flow sensor, inline type, DN 50

A

No display

A 1022

B

With display

A 1004

A

R type thread

A 1005

B

NPT type thread

A 1006

C

PT type thread

A 1023

A

Flow from left to right

A 1024

B

Flow from right to left

A 1007

A

Air

A 1008

B

CO2

A 1009

C

02

A 1010

D

N2

A 1012

F

Ar

A 1019

H

N20

0553 0104

Connection cable 5m, 5 pole

0553 0105

Connection cable 10m, 5 pole

0554 2005

Service kit for sensor configuration including software

0190 0001

Closing cap for measuring section AVA 420

0554 0007

Mains unit in wall housing 100-240 V, 10 VA, 50-60 Hz/24VDC, 0.35 A

0554 0107

Mains unit 100-240 VAC / 24 VDC, 0.5 A for AVA/AFA 400 Series, 2 m cable

3200 0001

Flow calibration with certificate

Technical data AVA 420

Measured unit

m³/h, m³/min, l/min, cfm, m/s,

kg/min, kg/h, kg/s

[Reference standard can be

programmed. Default values:

Air: Ps=1000 hPa, Ts=20℃

all other gases: Ps=1013 hPa, Ts=0℃

Accuracy

± [2% of measured value + 0.3%

full scale]

Temperature drift: 0.05% / K

Pressure drift: 0.05% / Bar

Stated

accuracy at

Ambient/process temperature

23℃±3℃

Ambient/process humidity < 90%,

no condensation

Process pressure at 0.6 Mpa

Mounting thread

R1/2", R3/4", R1", R1.5", R2"

DIN EN 10226 (ISO 7-1)

Principle of measurement

Thermal mass flow

Sensor

Glass coated resistive sensor

Measuring

medium

Air, N2, 02, Ar, N20, CO2

Operating

temperature

-30 to 50℃

Operating

pressure

up to 1.6 Mpa

Analogue

output

Signal: 4 to 20 mA

Scaling: 0 to maximum volume flow

Accuracy: 0.06 mA

Pulse output

20mA

1 pulse per m³, I, ft3 or kg, insulated

switch output max 30 VDC,

[pulse length: 30-120 ms, depends

on consumption rate)

Power supply

12-30 VDC, 100 mA

Display

128 x 64 pixel, with backlight

Material

Measuring section:

Stainless steel 1.4301

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
Thermal Mass Flow Sensor VA420

Thermal Mass Flow Sensor VA420

$0.00

Thermal Mass Flow Sensor VA420: overview and buying guide

The Thermal Mass Flow Sensor VA420 (model VA420) is made by AUTOFLOW and listed in our chemical range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Thermal Mass Flow Sensor VA420 cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Thermal Mass Flow Sensor VA420 to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine AUTOFLOW product?

We purchase directly from AUTOFLOW or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

AVA 420 thermal mass flow sensor

Dimensions

Flow measuring ranges AVA 420

Connection

thread

Outer pope

diam.mm

Inner pipe

diam.mm

Measuring

range from to

L

L1

H

H1

A

R 1/2"

21.3

16.1

0.2 ... 90 m3/h

300

210

176.4

165.7

20

R3/4"

26.9

21.7

0.3 ... 170 m3/h

475

275

179.2

165.7

20

R 1"

33.7

27.3

0.5 ... 290 m3/h

475

275

182.6

165.7

25

R 11/2"

48.3

41.8

1.0 ... 550 m3/h

475*

275

189.9

165.7

25

R2"

60.3

53.1

2.0 ... 900 m3/h

475*

275

195.9

165.7

30

* Attention: Shortened inlet section! Please observe the recommended minimum inlet section [length = 15 x inner diameter] on site.

Order no.

Display

Thread

Direction

Medium

Description

0695 0421

AVA 420, flow sensor, inline type, DN 15

0695 0422

AVA 420, flow sensor, inline type, DN 20

0695 0423

AVA 420, flow sensor, inline type, DN 25

0695 0424

AVA 420, flow sensor, inline type, DN 40

0695 0425

AVA 420, flow sensor, inline type, DN 50

A

No display

A 1022

B

With display

A 1004

A

R type thread

A 1005

B

NPT type thread

A 1006

C

PT type thread

A 1023

A

Flow from left to right

A 1024

B

Flow from right to left

A 1007

A

Air

A 1008

B

CO2

A 1009

C

02

A 1010

D

N2

A 1012

F

Ar

A 1019

H

N20

0553 0104

Connection cable 5m, 5 pole

0553 0105

Connection cable 10m, 5 pole

0554 2005

Service kit for sensor configuration including software

0190 0001

Closing cap for measuring section AVA 420

0554 0007

Mains unit in wall housing 100-240 V, 10 VA, 50-60 Hz/24VDC, 0.35 A

0554 0107

Mains unit 100-240 VAC / 24 VDC, 0.5 A for AVA/AFA 400 Series, 2 m cable

3200 0001

Flow calibration with certificate

Technical data AVA 420

Measured unit

m³/h, m³/min, l/min, cfm, m/s,

kg/min, kg/h, kg/s

[Reference standard can be

programmed. Default values:

Air: Ps=1000 hPa, Ts=20℃

all other gases: Ps=1013 hPa, Ts=0℃

Accuracy

± [2% of measured value + 0.3%

full scale]

Temperature drift: 0.05% / K

Pressure drift: 0.05% / Bar

Stated

accuracy at

Ambient/process temperature

23℃±3℃

Ambient/process humidity < 90%,

no condensation

Process pressure at 0.6 Mpa

Mounting thread

R1/2", R3/4", R1", R1.5", R2"

DIN EN 10226 (ISO 7-1)

Principle of measurement

Thermal mass flow

Sensor

Glass coated resistive sensor

Measuring

medium

Air, N2, 02, Ar, N20, CO2

Operating

temperature

-30 to 50℃

Operating

pressure

up to 1.6 Mpa

Analogue

output

Signal: 4 to 20 mA

Scaling: 0 to maximum volume flow

Accuracy: 0.06 mA

Pulse output

20mA

1 pulse per m³, I, ft3 or kg, insulated

switch output max 30 VDC,

[pulse length: 30-120 ms, depends

on consumption rate)

Power supply

12-30 VDC, 100 mA

Display

128 x 64 pixel, with backlight

Material

Measuring section:

Stainless steel 1.4301

Detailed specification sheets are shown in the product images.

Catalogues