Test Equipment TLS-M
Ultimate Test Equipment!
TLS-M
Optimal equipment for CPU Cooler development and verification
Optimized for measuring thermal resistance of computer CPU Coolers
Measures fast and accurate thermal resistance values
Easily adjusts heater heat generation and fan operating voltage
Heat source can be adjusted to various angles and directions to suit thermal resistance measurement of heat pipe coolers
Features
Product Features
◦Measurement of absolute value (thermal resistance value)
It is possible to measure the absolute value (thermal resistance value), not the relative comparative performance of the test sample (cooler).
a. When operating the Guard Heater, no heat loss occurs from the Main Heater.
b. Even when the Guard Heater is not operated, heat loss is minimal due to the faithful insulation structure, and the amount of lost heat, which varies depending on the cooler's performance, is precisely measured and reflected in the calculation of the thermal resistance value.
c. The Guard Heater changes flexibly according to the temperature of the Main Heater, and the difference between the two temperatures is within ±0.1℃. (However, if the ambient temperature changes frequently, the Main Heater's temperature will also change and not stabilize, so the Guard Heater's temperature tracking it will also not stabilize, which can lead to a larger difference between the two temperatures.)
◦Minimizing the influence of ambient temperature
The temperature sensor for temperature measurement is specially manufactured using a PT100 element in a 3-wire system, thus minimizing the influence of ambient temperature, unlike thermocouples.
a. Thermocouples generate voltage due to the temperature difference at the ends of two junctions, which is then converted and regarded as a temperature value. Therefore, without special calibration, if the ambient temperature is 10°C and the measured point is 30°C, it would treat the case where the ambient temperature is 20°C and the measured point is 40°C as the same. Consequently, most measuring equipment has a Cold Junction compensation function, but even with this function, its extent is limited. Thus, when using thermocouples, it is recommended to use them in an ambient environment of approximately 23°C ±2°C.
b. PT100 measures temperature using the inherent electrical resistance of a material that changes with temperature, thus it is hardly affected by ambient temperature.
◦The rate of resistance value change with temperature is very small.
a. The main heater uses a heating element containing ruthenium, a platinum group metal, so the rate of resistance change with temperature (0.02%/℃) is very small. Therefore, compared to other heating elements, the difference in heat generation between the initial setting and the stabilized state is small.
◦Precise thermal resistance value measurement is possible
a. By preventing heat loss through precise temperature sensors and guard heaters, more precise thermal resistance values can be measured.
b. When tests are performed under appropriate environmental conditions, accurate thermal resistance values can be measured with a deviation of less than ±0.002℃/W.
◦Forward horizontal, vertical, and reverse horizontal tests possible
a. The test sample can be mounted and tested in any desired direction. For example, it can be mounted at desired angles (0~180 degrees) for forward horizontal, vertical, and reverse horizontal positions relative to gravity, and the cooler can also be rotated and mounted in 0, 90, 180, and 270-degree directions for each mounting orientation.
Specs
Components
◦ TLS-M Main Unit
◦ AC 220V, 60Hz Power Cord
◦ Master Sample
◦ CompactFlash Card
Product Specifications
◦ Dimension(m/m) : 400(L) * 315(W) * 250(H)
◦ Simulated Heating Element: Platinum group metal plate-type heating element
◦ Guard Heater : Carbon-based planar heating element
◦ Temperature Measurement: Up to 6 channels can be measured
◦ Temperature Accuracy : 0.1 ℃
◦ Control: 2 loops (separate measurement of up to 4 temperature channels possible)
◦ Power Supply Unit
a.For heating element : DC 50V, 8A
b.For fan : DC 15V, 10A
Guide
How to Use
◦ Ensure all switches, including the main power switch on the back of the equipment, are off, and set the rotary knob for the main heater to the minimum (0-0).
◦ Mount the test sample (cooler) and turn on the main power switch on the back of the equipment.
◦ Adjust the fan setting rotary knob to supply appropriate voltage to the fan.
(The voltage that can be supplied to the fan is 0~15 volts. Be careful not to exceed the fan's maximum permissible voltage.)
◦ Turn on the 'Computation' switch to activate the calculation function, then set the heat output of the main heater.
◦ To check the trend of changes in temperature and other values on a graph, turn on the 'Save Data' switch.
◦ You can turn the Guard Heater on or off as needed.
◦ To save the screen and stop an active alarm, lightly press the "Save Screen" and "Clear Alarm" switches respectively for more than 1/4 second.
◦ For additional temperature measurements, connect a T-type thermocouple (Omega) to the blue connector on the back of the equipment. They will be displayed in the equipment's Option group with unique numbers 0, T-1, T-2, T-3 (0 is not usable), in order from the top.
Precautions Before Use
◦ Ambient Temperature: The ambient temperature for testing is not limited to a specific range. However, if the ambient temperature is controlled using an air conditioner or heater, or if air with a large temperature difference flows in through windows or doors, significant temperature changes occur in a short period, making precise thermal resistance measurement impossible. Therefore, please avoid performing tests near windows, doors, or frequently trafficked passages, and when forcibly adjusting air temperature, do not use ON/OFF controlled cooling or heating devices.
◦ In the case of coolers using heat pipes, the cooling performance of the cooler changes depending on the operating temperature of the heat pipe. For example, if the heat generation is high or the ambient temperature is high, leading to a high operating temperature of the heat pipe, the thermal resistance value will be significantly lower than when the heat generation is low or the ambient temperature is low, leading to a low operating temperature of the heat pipe. Therefore, when defining the thermal resistance value for a cooler with heat pipes, it would be desirable to define it as the thermal resistance value when the ambient temperature is 000 ℃ and the heat generation is 000 W.
◦ Most thermal greases exhibit a significant change in thermal resistance value for a certain period after application and cooler installation. In most cases, the thermal resistance value decreases, and the magnitude of this change gradually reduces over time. Therefore, to measure a more accurate thermal resistance value of a cooler, it is essential to consider the change in thermal resistance value of the thermal grease over time.
Precautions During Use
◦ Always install the test sample and operate the fan at the desired voltage before turning on the main heater.
◦ If the main heater temperature exceeds 150 ℃ or the case temp. (temperature of the heating block) exceeds 120 ℃, the power to the main heater and guard heater will be automatically cut off, and a blinking alarm will appear on the display screen.
◦ If an alarm is triggered and the main heater power is cut off, it is because the test sample (cooler) is incorrectly mounted, the fan is not operating normally, or the cooling performance of the test sample is insufficient to cool the set heat output. Therefore, to resume testing, check the mounting status of the test sample and the operating status of the fan, then appropriately reduce the main heater's heat output and press the "Clear Alarm" button. However, if the temperature of the main heater or heating block still exceeds the alarm temperature, the "Clear Alarm" function will not operate to prevent damage to the product.
◦ The test table has fixing holes that allow it to be locked in position at 0, 90, and 180 degrees around its rotation axis. If the knob is inserted into a hole and excessive force is applied to rotate the table, the equipment may be damaged. Therefore, always rotate the test table gently, and if it does not rotate, sufficiently loosen the knob before rotating it gently.
Detailed specification sheets are shown in the product images.
Test Equipment TLS-M
Test Equipment TLS-M: overview and buying guide
The Test Equipment TLS-M (model TLS-M) is made by Thermolab and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Test Equipment TLS-M cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Test Equipment TLS-M to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine Thermolab product?
We purchase directly from Thermolab or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Ultimate Test Equipment!
TLS-M
Optimal equipment for CPU Cooler development and verification
Optimized for measuring thermal resistance of computer CPU Coolers
Measures fast and accurate thermal resistance values
Easily adjusts heater heat generation and fan operating voltage
Heat source can be adjusted to various angles and directions to suit thermal resistance measurement of heat pipe coolers
Features
Product Features
◦Measurement of absolute value (thermal resistance value)
It is possible to measure the absolute value (thermal resistance value), not the relative comparative performance of the test sample (cooler).
a. When operating the Guard Heater, no heat loss occurs from the Main Heater.
b. Even when the Guard Heater is not operated, heat loss is minimal due to the faithful insulation structure, and the amount of lost heat, which varies depending on the cooler's performance, is precisely measured and reflected in the calculation of the thermal resistance value.
c. The Guard Heater changes flexibly according to the temperature of the Main Heater, and the difference between the two temperatures is within ±0.1℃. (However, if the ambient temperature changes frequently, the Main Heater's temperature will also change and not stabilize, so the Guard Heater's temperature tracking it will also not stabilize, which can lead to a larger difference between the two temperatures.)
◦Minimizing the influence of ambient temperature
The temperature sensor for temperature measurement is specially manufactured using a PT100 element in a 3-wire system, thus minimizing the influence of ambient temperature, unlike thermocouples.
a. Thermocouples generate voltage due to the temperature difference at the ends of two junctions, which is then converted and regarded as a temperature value. Therefore, without special calibration, if the ambient temperature is 10°C and the measured point is 30°C, it would treat the case where the ambient temperature is 20°C and the measured point is 40°C as the same. Consequently, most measuring equipment has a Cold Junction compensation function, but even with this function, its extent is limited. Thus, when using thermocouples, it is recommended to use them in an ambient environment of approximately 23°C ±2°C.
b. PT100 measures temperature using the inherent electrical resistance of a material that changes with temperature, thus it is hardly affected by ambient temperature.
◦The rate of resistance value change with temperature is very small.
a. The main heater uses a heating element containing ruthenium, a platinum group metal, so the rate of resistance change with temperature (0.02%/℃) is very small. Therefore, compared to other heating elements, the difference in heat generation between the initial setting and the stabilized state is small.
◦Precise thermal resistance value measurement is possible
a. By preventing heat loss through precise temperature sensors and guard heaters, more precise thermal resistance values can be measured.
b. When tests are performed under appropriate environmental conditions, accurate thermal resistance values can be measured with a deviation of less than ±0.002℃/W.
◦Forward horizontal, vertical, and reverse horizontal tests possible
a. The test sample can be mounted and tested in any desired direction. For example, it can be mounted at desired angles (0~180 degrees) for forward horizontal, vertical, and reverse horizontal positions relative to gravity, and the cooler can also be rotated and mounted in 0, 90, 180, and 270-degree directions for each mounting orientation.
Specs
Components
◦ TLS-M Main Unit
◦ AC 220V, 60Hz Power Cord
◦ Master Sample
◦ CompactFlash Card
Product Specifications
◦ Dimension(m/m) : 400(L) * 315(W) * 250(H)
◦ Simulated Heating Element: Platinum group metal plate-type heating element
◦ Guard Heater : Carbon-based planar heating element
◦ Temperature Measurement: Up to 6 channels can be measured
◦ Temperature Accuracy : 0.1 ℃
◦ Control: 2 loops (separate measurement of up to 4 temperature channels possible)
◦ Power Supply Unit
a.For heating element : DC 50V, 8A
b.For fan : DC 15V, 10A
Guide
How to Use
◦ Ensure all switches, including the main power switch on the back of the equipment, are off, and set the rotary knob for the main heater to the minimum (0-0).
◦ Mount the test sample (cooler) and turn on the main power switch on the back of the equipment.
◦ Adjust the fan setting rotary knob to supply appropriate voltage to the fan.
(The voltage that can be supplied to the fan is 0~15 volts. Be careful not to exceed the fan's maximum permissible voltage.)
◦ Turn on the 'Computation' switch to activate the calculation function, then set the heat output of the main heater.
◦ To check the trend of changes in temperature and other values on a graph, turn on the 'Save Data' switch.
◦ You can turn the Guard Heater on or off as needed.
◦ To save the screen and stop an active alarm, lightly press the "Save Screen" and "Clear Alarm" switches respectively for more than 1/4 second.
◦ For additional temperature measurements, connect a T-type thermocouple (Omega) to the blue connector on the back of the equipment. They will be displayed in the equipment's Option group with unique numbers 0, T-1, T-2, T-3 (0 is not usable), in order from the top.
Precautions Before Use
◦ Ambient Temperature: The ambient temperature for testing is not limited to a specific range. However, if the ambient temperature is controlled using an air conditioner or heater, or if air with a large temperature difference flows in through windows or doors, significant temperature changes occur in a short period, making precise thermal resistance measurement impossible. Therefore, please avoid performing tests near windows, doors, or frequently trafficked passages, and when forcibly adjusting air temperature, do not use ON/OFF controlled cooling or heating devices.
◦ In the case of coolers using heat pipes, the cooling performance of the cooler changes depending on the operating temperature of the heat pipe. For example, if the heat generation is high or the ambient temperature is high, leading to a high operating temperature of the heat pipe, the thermal resistance value will be significantly lower than when the heat generation is low or the ambient temperature is low, leading to a low operating temperature of the heat pipe. Therefore, when defining the thermal resistance value for a cooler with heat pipes, it would be desirable to define it as the thermal resistance value when the ambient temperature is 000 ℃ and the heat generation is 000 W.
◦ Most thermal greases exhibit a significant change in thermal resistance value for a certain period after application and cooler installation. In most cases, the thermal resistance value decreases, and the magnitude of this change gradually reduces over time. Therefore, to measure a more accurate thermal resistance value of a cooler, it is essential to consider the change in thermal resistance value of the thermal grease over time.
Precautions During Use
◦ Always install the test sample and operate the fan at the desired voltage before turning on the main heater.
◦ If the main heater temperature exceeds 150 ℃ or the case temp. (temperature of the heating block) exceeds 120 ℃, the power to the main heater and guard heater will be automatically cut off, and a blinking alarm will appear on the display screen.
◦ If an alarm is triggered and the main heater power is cut off, it is because the test sample (cooler) is incorrectly mounted, the fan is not operating normally, or the cooling performance of the test sample is insufficient to cool the set heat output. Therefore, to resume testing, check the mounting status of the test sample and the operating status of the fan, then appropriately reduce the main heater's heat output and press the "Clear Alarm" button. However, if the temperature of the main heater or heating block still exceeds the alarm temperature, the "Clear Alarm" function will not operate to prevent damage to the product.
◦ The test table has fixing holes that allow it to be locked in position at 0, 90, and 180 degrees around its rotation axis. If the knob is inserted into a hole and excessive force is applied to rotate the table, the equipment may be damaged. Therefore, always rotate the test table gently, and if it does not rotate, sufficiently loosen the knob before rotating it gently.
Detailed specification sheets are shown in the product images.