Test and Measurement – illustrative image, not the exact model
New

Temperature & Humidity Chamber STHN 701

Temperature & Humidity Chamber


Specifications

General Specifications for the STANDARD & WELL-KNOWN STYLE

STHN 701

STHN 702

STHN 703

Internal Workzone Dimension (LxDxH)

500 x 500 x 600mm

500 x 500 x 600mm

500 x 500 x 600mm

Compressor

1/2HP - 1ea

1 HP - 1ea 

1/2HP - 2ea, 1/4HP - 1ea

Capacity

150 Liters

150 Liters

150 Liters

Temperature Range

-10°C  to 100°C 

-30°C to 100°C 

-40°C  to 100°C 

General Specifications for the STANDARD & WELL-KNOWN STYLE

STHN 701-L

STHN 702-L

STHN 703-L

Internal Workzone Dimension (LxDxH)

600 x 600 x 800mm

600 x 600 x800mm

600 x 600 x 800mm

Compressor

3/4 HP - 1ea

2 HP - 1ea 

3/4 HP - 2ea, 1/2HP - 1ea

Capacity

288 Liters

288 Liters

288 Liters

Option(1)

Recorder (Printing Type)

Recorder (Printing Type)

Recorder (Printing Type)

Option(2)

Temp/Hunmidity Program Controller

Temp/Hunmidity Program Controller

Temp/Hunmidity Program Controller

Temperature Range

-10°C  to 100°C 

-30°C to 100°C 

-40°C  to 100°C 

Common Specifications for all the STHN model Lineup

Temperature

Accuracy

±0.5°C  at 37°C 

Controller

Microprocessor Digital P.I.D Controller(Optional : Touch-Screen Controller / Digital Recorder  

Humidity

Range

30% to 95%

Controller

Microprocessor Digital P.I.D Controller (Opational : Touch - Screen Controller / Digital Recorder)

Accuracy

±3% at 60%

Shelves

3ea

Safety Device 

Over Tempeature, Over Load Breaker, Motor Over Load, Heater Breaker, Power Breaker

Suppy Voltage & Frequency

AC 220V, 50/60Hz

Features

  • With a design featuring a two - tone color scheme that conveys a sense of luxury and reliability, the right control unit allows for the replacement of only the plate to meet customer-desired specifications, and The blind-style ventilation opening features a cool image and is designed for convenient filter replacement.

  • It can be controlled via PC using RS-485 communication, allowing for remote control of the device with minimal personnel, and for data storage and collection as well. It is convenient (Option)

  • If overheating of the heating or humidifying heater is detected, an alarm sounds, and if there is no user inspection, the device automatically stops operating, and The secondary main power is cut off.

  • An alarm sounds when the water in the humidification tank is depleted, and if the water in the water level control container of the Bath inside the Chamber is also depleted, the device's Operation stops automatically, and the main power is cut off.

  • If a short circuit occurs or an overcurrent flows, the device will automatically stop operating and the main power supply will be cut off.

  • A temperature regulator is installed inside the chamber so that the secondary main power is automatically cut off when the temperature inside the chamber overheats.

Error product group when enable variant picker

Availability: In stock
Test and Measurement – illustrative image, not the exact model

Temperature & Humidity Chamber STHN 701

$0.00

Temperature & Humidity Chamber STHN 701: overview and buying guide

The Temperature & Humidity Chamber STHN 701 (model STHN 701) is made by Shinsaeng and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Temperature & Humidity Chamber STHN 701 cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Temperature & Humidity Chamber STHN 701 to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine Shinsaeng product?

We purchase directly from Shinsaeng or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

Temperature & Humidity Chamber


Specifications

General Specifications for the STANDARD & WELL-KNOWN STYLE

STHN 701

STHN 702

STHN 703

Internal Workzone Dimension (LxDxH)

500 x 500 x 600mm

500 x 500 x 600mm

500 x 500 x 600mm

Compressor

1/2HP - 1ea

1 HP - 1ea 

1/2HP - 2ea, 1/4HP - 1ea

Capacity

150 Liters

150 Liters

150 Liters

Temperature Range

-10°C  to 100°C 

-30°C to 100°C 

-40°C  to 100°C 

General Specifications for the STANDARD & WELL-KNOWN STYLE

STHN 701-L

STHN 702-L

STHN 703-L

Internal Workzone Dimension (LxDxH)

600 x 600 x 800mm

600 x 600 x800mm

600 x 600 x 800mm

Compressor

3/4 HP - 1ea

2 HP - 1ea 

3/4 HP - 2ea, 1/2HP - 1ea

Capacity

288 Liters

288 Liters

288 Liters

Option(1)

Recorder (Printing Type)

Recorder (Printing Type)

Recorder (Printing Type)

Option(2)

Temp/Hunmidity Program Controller

Temp/Hunmidity Program Controller

Temp/Hunmidity Program Controller

Temperature Range

-10°C  to 100°C 

-30°C to 100°C 

-40°C  to 100°C 

Common Specifications for all the STHN model Lineup

Temperature

Accuracy

±0.5°C  at 37°C 

Controller

Microprocessor Digital P.I.D Controller(Optional : Touch-Screen Controller / Digital Recorder  

Humidity

Range

30% to 95%

Controller

Microprocessor Digital P.I.D Controller (Opational : Touch - Screen Controller / Digital Recorder)

Accuracy

±3% at 60%

Shelves

3ea

Safety Device 

Over Tempeature, Over Load Breaker, Motor Over Load, Heater Breaker, Power Breaker

Suppy Voltage & Frequency

AC 220V, 50/60Hz

Features

  • With a design featuring a two - tone color scheme that conveys a sense of luxury and reliability, the right control unit allows for the replacement of only the plate to meet customer-desired specifications, and The blind-style ventilation opening features a cool image and is designed for convenient filter replacement.

  • It can be controlled via PC using RS-485 communication, allowing for remote control of the device with minimal personnel, and for data storage and collection as well. It is convenient (Option)

  • If overheating of the heating or humidifying heater is detected, an alarm sounds, and if there is no user inspection, the device automatically stops operating, and The secondary main power is cut off.

  • An alarm sounds when the water in the humidification tank is depleted, and if the water in the water level control container of the Bath inside the Chamber is also depleted, the device's Operation stops automatically, and the main power is cut off.

  • If a short circuit occurs or an overcurrent flows, the device will automatically stop operating and the main power supply will be cut off.

  • A temperature regulator is installed inside the chamber so that the secondary main power is automatically cut off when the temperature inside the chamber overheats.