{"product_id":"surface-area-analyzer-bet-131019","title":"Surface Area Analyzer (BET) HM Model-1208","description":"\u003cp\u003e\u003cstrong\u003eHM Model-1208 \/ HM Model-1210\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e8\/10 Sample Automatic Auto sampler type\u003c\/p\u003e \u003cp\u003eThis is an industry-standard model of an automatic continuous measurement system that achieves optimal harmony in terms of processing capability, compactness, and price. By installing an 8\/10 sample type Auto sampler with the standard system Model-1201, automatic continuous measurement of up to 8\/10 samples is possible.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eStandard Configuration\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e• Macsorb Main Unit\u003c\/p\u003e \u003cp\u003e• 8\/10 Sample Auto sampler Unit\u003c\/p\u003e \u003cp\u003e• PC for Control \u0026amp; Analysis (Microsoft Windows 7 installed)\u003c\/p\u003e \u003cp\u003e• Dedicated Control \u0026amp; Analysis Software\u003c\/p\u003e \u003cp\u003e• LCD Monitor (15 inch)\u003c\/p\u003e \u003cp\u003e• Printer for Data Output (Inkjet type)\u003c\/p\u003e \u003cp\u003e• Dewar Flask (1ℓ\/2ℓ)\u003c\/p\u003e \u003cp\u003e• Sample cell (10 pcs)\u003c\/p\u003e \u003cp\u003e• Sample Injector (1000 pcs)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMacsorb® \u003c\/p\u003e \u003cp\u003eFully Automatic BET Specific Surface Area Measurement Device\u003c\/p\u003e \u003cp\u003eSpecific surface area measurement, indispensable for characterizing powders, is becoming increasingly important in quality control due to the pulverization and multi-functionalization of powders. In production sites, evaluation of raw materials and final products, as well as intermediate products, is required, and the inspection of specific surface area measurements is rapidly increasing. The fully automatic specific surface area measurement device Macsorb enables rapid and high-precision specific surface area measurement by automating all processes, including direct control by PC and pretreatment.  \u003c\/p\u003e \u003cp\u003eMulti-sample unattended measurement is also possible by combining it with a selectable Auto sampler tailored to on-site requirements.   \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e1. 1-unit type Preheater Unit\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eReduced measurement time when using the simple 1-unit Free heat unit Model-1201 \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e2. 8-series Preheater Unit\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eA 4-continuous x 2-unit type Free heat unit that further shortens measurement time, allowing 8 samples to be processed at once under the same degassing conditions. \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e3. Independent 5-series Preheater Unit\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eA 5-series Free heat unit with independent temperature control that shortens the measurement time for samples with different degassing conditions. \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e4. Gas Switching Unit for Multi-method Measurement\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eGas switching unit that enables multi-method measurement with Macsorb\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eCommon Specifications\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e※Measuring Instrument Main Unit \u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eBET Flow Method (1-point method\/multi-point method option)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e0.01~4000㎡\/g (Depends on Sample characteristics)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eReproducibility ±1% (Depends on Sample)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eGas Used\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePure Nitrogen and Mixed Gas (Nitrogen 30% + Helium 70%)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eDegassing Temperature\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMax 450℃\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApprox. 30Kg (Measuring instrument main unit only) Dimensions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eW310xD600xH570 (Measuring instrument main unit only)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eApprox. 30Kg (Measuring instrument main unit only)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e※PC for Control (Our designated model)\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd rowspan=\"5\"\u003e\u003cstrong\u003ePC Main Unit\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePC\/AT compatible machine capable of running Windows XP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCPU : Compliant with OS requirements (Intel Pentium compatible 1.4GHz or higher recommended)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRAM : 512MB or more recommended\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCD-ROM drive required for control\/analysis software installation\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRS-232C port required for communication with the measuring instrument main unit\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMonitor\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eVGA compatible, XGA or higher recommended\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePrinter\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eInkjet (Standard) \/ Laser type\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eModel \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eHM Model-1201 \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eHM Model-1208 \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eHM Model-1210 \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eHM Model-1220 \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eHM Model-1230\u003c\/strong\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eMeasurement Principle \u003c\/strong\u003e \u003c\/td\u003e \u003ctd colspan=\"5\"\u003e BET Flow Method (1-point method \/ multi-point method) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eMeasurement Range \u003c\/strong\u003e \u003c\/td\u003e \u003ctd colspan=\"5\"\u003e 0.01~4000㎡\/g (Depends on Sample characteristics) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eMeasurement Accuracy \u003c\/strong\u003e \u003c\/td\u003e \u003ctd colspan=\"5\"\u003e Reproducibility ±1% (Depends on Sample) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eMeasurement Time \u003c\/strong\u003e \u003c\/td\u003e \u003ctd colspan=\"5\"\u003e Approx. 10 min \/ 1 sample (excluding pretreatment) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eGas Used \u003c\/strong\u003e \u003c\/td\u003e \u003ctd colspan=\"5\"\u003e Pure Nitrogen and Mixed Gas (Nitrogen 30% + Helium 70%) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eNumber of Continuous Automatic Measurement Samples \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e 1 sample  \u003c\/td\u003e \u003ctd\u003e 8 samples  \u003c\/td\u003e \u003ctd\u003e 10 samples  \u003c\/td\u003e \u003ctd\u003e 20 samples  \u003c\/td\u003e \u003ctd\u003e 30 samples \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eAuto Sampler \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e  -  \u003c\/td\u003e \u003ctd\u003e 8 samples  \u003c\/td\u003e \u003ctd\u003e 10 samples  \u003c\/td\u003e \u003ctd\u003e 20 samples  \u003c\/td\u003e \u003ctd\u003e 30 samples \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eDimensions (Main Unit + AS) \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e W310xD600xH570 \u003c\/td\u003e \u003ctd\u003e W610xD750xH570  \u003c\/td\u003e \u003ctd\u003e W610xD750xH570  \u003c\/td\u003e \u003ctd\u003e W810xD850xH570  \u003c\/td\u003e \u003ctd\u003e W930xD900xH570 \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003ePower Supply \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e 100V, 50\/60Hz 2A  \u003c\/td\u003e \u003ctd colspan=\"4\"\u003e 100V, 50\/60Hz 4A  \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eMulti-point method measurement \u003c\/strong\u003e \u003c\/td\u003e \u003ctd colspan=\"5\"\u003e Option \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e","brand":"SAMBOO SYSTEM","offers":[{"title":"Default Title","offer_id":58446429651284,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/a5e1a72d-3f7b-4cb0-a5ee-2fcbb26dd83a.jpg?v=1795190872","url":"https:\/\/premiumemart.com\/products\/surface-area-analyzer-bet-131019","provider":"Premium Emart","version":"1.0","type":"link"}