Surface Area Analyzer (BET) HM Model-1208
HM Model-1208 / HM Model-1210
8/10 Sample Automatic Auto sampler type
This is an industry-standard model of an automatic continuous measurement system that achieves optimal harmony in terms of processing capability, compactness, and price. By installing an 8/10 sample type Auto sampler with the standard system Model-1201, automatic continuous measurement of up to 8/10 samples is possible.
Standard Configuration
• Macsorb Main Unit
• 8/10 Sample Auto sampler Unit
• PC for Control & Analysis (Microsoft Windows 7 installed)
• Dedicated Control & Analysis Software
• LCD Monitor (15 inch)
• Printer for Data Output (Inkjet type)
• Dewar Flask (1ℓ/2ℓ)
• Sample cell (10 pcs)
• Sample Injector (1000 pcs)
Overview
Macsorb®
Fully Automatic BET Specific Surface Area Measurement Device
Specific surface area measurement, indispensable for characterizing powders, is becoming increasingly important in quality control due to the pulverization and multi-functionalization of powders. In production sites, evaluation of raw materials and final products, as well as intermediate products, is required, and the inspection of specific surface area measurements is rapidly increasing. The fully automatic specific surface area measurement device Macsorb enables rapid and high-precision specific surface area measurement by automating all processes, including direct control by PC and pretreatment.
Multi-sample unattended measurement is also possible by combining it with a selectable Auto sampler tailored to on-site requirements.
1. 1-unit type Preheater Unit
Reduced measurement time when using the simple 1-unit Free heat unit Model-1201
2. 8-series Preheater Unit
A 4-continuous x 2-unit type Free heat unit that further shortens measurement time, allowing 8 samples to be processed at once under the same degassing conditions.
3. Independent 5-series Preheater Unit
A 5-series Free heat unit with independent temperature control that shortens the measurement time for samples with different degassing conditions.
4. Gas Switching Unit for Multi-method Measurement
Gas switching unit that enables multi-method measurement with Macsorb
Common Specifications
※Measuring Instrument Main Unit
| Measurement Principle | BET Flow Method (1-point method/multi-point method option) |
| Measurement Range | 0.01~4000㎡/g (Depends on Sample characteristics) |
| Measurement Accuracy | Reproducibility ±1% (Depends on Sample) |
| Gas Used | Pure Nitrogen and Mixed Gas (Nitrogen 30% + Helium 70%) |
| Degassing Temperature | Max 450℃ |
| Approx. 30Kg (Measuring instrument main unit only) Dimensions | W310xD600xH570 (Measuring instrument main unit only) |
| Weight | Approx. 30Kg (Measuring instrument main unit only) |
※PC for Control (Our designated model)
| PC Main Unit | PC/AT compatible machine capable of running Windows XP |
| CPU : Compliant with OS requirements (Intel Pentium compatible 1.4GHz or higher recommended) | |
| RAM : 512MB or more recommended | |
| CD-ROM drive required for control/analysis software installation | |
| RS-232C port required for communication with the measuring instrument main unit | |
| Monitor | VGA compatible, XGA or higher recommended |
| Printer | Inkjet (Standard) / Laser type |
Specification
| Model | HM Model-1201 | HM Model-1208 | HM Model-1210 | HM Model-1220 | HM Model-1230 |
| Measurement Principle | BET Flow Method (1-point method / multi-point method) | ||||
| Measurement Range | 0.01~4000㎡/g (Depends on Sample characteristics) | ||||
| Measurement Accuracy | Reproducibility ±1% (Depends on Sample) | ||||
| Measurement Time | Approx. 10 min / 1 sample (excluding pretreatment) | ||||
| Gas Used | Pure Nitrogen and Mixed Gas (Nitrogen 30% + Helium 70%) | ||||
| Number of Continuous Automatic Measurement Samples | 1 sample | 8 samples | 10 samples | 20 samples | 30 samples |
| Auto Sampler | - | 8 samples | 10 samples | 20 samples | 30 samples |
| Dimensions (Main Unit + AS) | W310xD600xH570 | W610xD750xH570 | W610xD750xH570 | W810xD850xH570 | W930xD900xH570 |
| Power Supply | 100V, 50/60Hz 2A | 100V, 50/60Hz 4A | |||
| Multi-point method measurement | Option | ||||
Detailed specification sheets are shown in the product images.
Surface Area Analyzer (BET) HM Model-1208
Surface Area Analyzer (BET) HM Model-1208: overview and buying guide
The Surface Area Analyzer (BET) HM Model-1208 (model HM Model-1208) is made by SAMBOO SYSTEM and listed in our chemical range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Surface Area Analyzer (BET) HM Model-1208 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Surface Area Analyzer (BET) HM Model-1208 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine SAMBOO SYSTEM product?
We purchase directly from SAMBOO SYSTEM or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
HM Model-1208 / HM Model-1210
8/10 Sample Automatic Auto sampler type
This is an industry-standard model of an automatic continuous measurement system that achieves optimal harmony in terms of processing capability, compactness, and price. By installing an 8/10 sample type Auto sampler with the standard system Model-1201, automatic continuous measurement of up to 8/10 samples is possible.
Standard Configuration
• Macsorb Main Unit
• 8/10 Sample Auto sampler Unit
• PC for Control & Analysis (Microsoft Windows 7 installed)
• Dedicated Control & Analysis Software
• LCD Monitor (15 inch)
• Printer for Data Output (Inkjet type)
• Dewar Flask (1ℓ/2ℓ)
• Sample cell (10 pcs)
• Sample Injector (1000 pcs)
Overview
Macsorb®
Fully Automatic BET Specific Surface Area Measurement Device
Specific surface area measurement, indispensable for characterizing powders, is becoming increasingly important in quality control due to the pulverization and multi-functionalization of powders. In production sites, evaluation of raw materials and final products, as well as intermediate products, is required, and the inspection of specific surface area measurements is rapidly increasing. The fully automatic specific surface area measurement device Macsorb enables rapid and high-precision specific surface area measurement by automating all processes, including direct control by PC and pretreatment.
Multi-sample unattended measurement is also possible by combining it with a selectable Auto sampler tailored to on-site requirements.
1. 1-unit type Preheater Unit
Reduced measurement time when using the simple 1-unit Free heat unit Model-1201
2. 8-series Preheater Unit
A 4-continuous x 2-unit type Free heat unit that further shortens measurement time, allowing 8 samples to be processed at once under the same degassing conditions.
3. Independent 5-series Preheater Unit
A 5-series Free heat unit with independent temperature control that shortens the measurement time for samples with different degassing conditions.
4. Gas Switching Unit for Multi-method Measurement
Gas switching unit that enables multi-method measurement with Macsorb
Common Specifications
※Measuring Instrument Main Unit
| Measurement Principle | BET Flow Method (1-point method/multi-point method option) |
| Measurement Range | 0.01~4000㎡/g (Depends on Sample characteristics) |
| Measurement Accuracy | Reproducibility ±1% (Depends on Sample) |
| Gas Used | Pure Nitrogen and Mixed Gas (Nitrogen 30% + Helium 70%) |
| Degassing Temperature | Max 450℃ |
| Approx. 30Kg (Measuring instrument main unit only) Dimensions | W310xD600xH570 (Measuring instrument main unit only) |
| Weight | Approx. 30Kg (Measuring instrument main unit only) |
※PC for Control (Our designated model)
| PC Main Unit | PC/AT compatible machine capable of running Windows XP |
| CPU : Compliant with OS requirements (Intel Pentium compatible 1.4GHz or higher recommended) | |
| RAM : 512MB or more recommended | |
| CD-ROM drive required for control/analysis software installation | |
| RS-232C port required for communication with the measuring instrument main unit | |
| Monitor | VGA compatible, XGA or higher recommended |
| Printer | Inkjet (Standard) / Laser type |
Specification
| Model | HM Model-1201 | HM Model-1208 | HM Model-1210 | HM Model-1220 | HM Model-1230 |
| Measurement Principle | BET Flow Method (1-point method / multi-point method) | ||||
| Measurement Range | 0.01~4000㎡/g (Depends on Sample characteristics) | ||||
| Measurement Accuracy | Reproducibility ±1% (Depends on Sample) | ||||
| Measurement Time | Approx. 10 min / 1 sample (excluding pretreatment) | ||||
| Gas Used | Pure Nitrogen and Mixed Gas (Nitrogen 30% + Helium 70%) | ||||
| Number of Continuous Automatic Measurement Samples | 1 sample | 8 samples | 10 samples | 20 samples | 30 samples |
| Auto Sampler | - | 8 samples | 10 samples | 20 samples | 30 samples |
| Dimensions (Main Unit + AS) | W310xD600xH570 | W610xD750xH570 | W610xD750xH570 | W810xD850xH570 | W930xD900xH570 |
| Power Supply | 100V, 50/60Hz 2A | 100V, 50/60Hz 4A | |||
| Multi-point method measurement | Option | ||||