{"product_id":"surface-area-analyzer-bet-131018","title":"Surface Area Analyzer (BET) HM Model-1201","description":"\u003cp\u003e\u003cstrong\u003eHM Model-1201\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eStandard 1 sample automatic measurement type\u003c\/p\u003e \u003cp\u003eThis is the standard and minimum configuration of Macsorb, widely used from research laboratories to production sites.\u003cbr\u003eOnce a sample is set, everything from pre-treatment to measurement completion is performed automatically.\u003cbr\u003eAfter purchase, as usage frequency increases, an auto sampler can be added to expand it into an 8~30 point automatic operation system, and multi-point measurement is also possible with an optional gas switching unit.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e• Macsorb main unit\u003c\/p\u003e \u003cp\u003e• PC for control and analysis (equipped with Microsoft Windows 7)\u003c\/p\u003e \u003cp\u003e• Dedicated control and analysis software\u003c\/p\u003e \u003cp\u003e• LCD monitor (15 inch)\u003c\/p\u003e \u003cp\u003e• Printer for data output (inkjet type)\u003c\/p\u003e \u003cp\u003e• Dewar flask (300ml)\u003c\/p\u003e \u003cp\u003e• Sample cell (10 pcs)\u003c\/p\u003e \u003cp\u003e• Sample injector (100 pcs)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMacsorb® \u003c\/p\u003e \u003cp\u003eFully automatic BET specific surface area measuring device\u003c\/p\u003e \u003cp\u003eSpecific surface area measurement, indispensable for evaluating powder characteristics, is becoming increasingly important in quality control due to the micronization and multi-functionalization of powders. At production sites, evaluation of not only raw materials and final products but also intermediate products is required, and the inspection of specific surface area measurements is rapidly increasing. The fully automatic specific surface area measuring device Macsorb enables rapid and high-precision specific surface area measurement by automating all processes, including direct control by PC and pre-treatment. Multi-sample unattended measurement is also possible through combination with a selectable auto sampler tailored to on-site requirements.   \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e1. 1-unit Preheater Unit\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eReduced measurement time when using the simple 1-unit Free heat unit Model-1201\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e2. 8-series Preheater Unit\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eA 4-continuous x 2-type Free heat unit that further reduces measurement time, allowing 8 samples to be processed at once under the same degassing conditions.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e3. Independent 5-series Preheater Unit\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eA 5-series Free heat unit with independent temperature control that shortens measurement time for samples with different degassing conditions.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e4. Gas Switching Unit for Multi-point Measurement\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eGas switching unit that enables multi-point measurement with Macsorb\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eCommon Specifications\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e※Measuring instrument main unit \u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eBET flow method (1-point method\/multi-point method option)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e0.01~4000㎡\/g (Depends on sample characteristics)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eReproducibility ±1% (Depends on sample)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eGas Used\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePure nitrogen and mixed gas (nitrogen 30% + helium 70%)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eDegassing Temperature\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMax 450℃\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApprox. 30Kg (measuring instrument main unit only) Dimensions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eW310xD600xH570 (measuring instrument main unit only)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eApprox. 30Kg (measuring instrument main unit only)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e※Control PC (Company specified model)\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd rowspan=\"5\"\u003e\u003cstrong\u003ePC Main Unit\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePC\/AT compatible machine capable of running Windows XP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCPU: Conforms to OS requirements (Intel Pentium compatible 1.4GHz or higher recommended)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRAM: 512MB or more recommended\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCD-ROM drive required for installing control\/analysis software\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRS-232C port required for communication with the measuring instrument main unit\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMonitor\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eVGA compatible, XGA or higher recommended\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePrinter\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eInkjet (standard) \/ Laser type\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eModel \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eHM Model-1201 \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eHM Model-1208 \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eHM Model-1210 \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eHM Model-1220 \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eHM Model-1230\u003c\/strong\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eMeasurement Principle \u003c\/strong\u003e \u003c\/td\u003e \u003ctd colspan=\"5\"\u003e BET flow method (1-point method \/ multi-point method) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eMeasurement Range \u003c\/strong\u003e \u003c\/td\u003e \u003ctd colspan=\"5\"\u003e 0.01~4000㎡\/g (Depends on sample characteristics) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eMeasurement Accuracy \u003c\/strong\u003e \u003c\/td\u003e \u003ctd colspan=\"5\"\u003e Reproducibility ±1% (Depends on sample) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eMeasurement Time \u003c\/strong\u003e \u003c\/td\u003e \u003ctd colspan=\"5\"\u003e Approx. 10 minutes \/ 1 sample (excluding pre-treatment) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eGas Used \u003c\/strong\u003e \u003c\/td\u003e \u003ctd colspan=\"5\"\u003e Pure nitrogen and mixed gas (nitrogen 30% + helium 70%) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eNumber of Continuous Automatic Measurement Samples \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e 1 sample  \u003c\/td\u003e \u003ctd\u003e 8 samples  \u003c\/td\u003e \u003ctd\u003e 10 samples  \u003c\/td\u003e \u003ctd\u003e 20 samples  \u003c\/td\u003e \u003ctd\u003e 30 samples \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eAuto Sampler \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e  -  \u003c\/td\u003e \u003ctd\u003e 8 samples  \u003c\/td\u003e \u003ctd\u003e 10 samples  \u003c\/td\u003e \u003ctd\u003e 20 samples  \u003c\/td\u003e \u003ctd\u003e 30 samples \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eDimensions (Main unit + AS) \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e W310xD600xH570 \u003c\/td\u003e \u003ctd\u003e W610xD750xH570  \u003c\/td\u003e \u003ctd\u003e W610xD750xH570  \u003c\/td\u003e \u003ctd\u003e W810xD850xH570  \u003c\/td\u003e \u003ctd\u003e W930xD900xH570 \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003ePower \u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e 100V, 50\/60Hz 2A  \u003c\/td\u003e \u003ctd colspan=\"4\"\u003e 100V, 50\/60Hz 4A  \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eMulti-point Measurement \u003c\/strong\u003e \u003c\/td\u003e \u003ctd colspan=\"5\"\u003e Option \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e","brand":"SAMBOO SYSTEM","offers":[{"title":"Default Title","offer_id":58446429159764,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/b1d56e38-6ce9-44e4-9ce9-e1fa73d9dbb9.jpg?v=1795190871","url":"https:\/\/premiumemart.com\/products\/surface-area-analyzer-bet-131018","provider":"Premium Emart","version":"1.0","type":"link"}