Surface Area Analyzer (BET) HM Model-1201
HM Model-1201
Standard 1 sample automatic measurement type
This is the standard and minimum configuration of Macsorb, widely used from research laboratories to production sites.
Once a sample is set, everything from pre-treatment to measurement completion is performed automatically.
After purchase, as usage frequency increases, an auto sampler can be added to expand it into an 8~30 point automatic operation system, and multi-point measurement is also possible with an optional gas switching unit.
Features
• Macsorb main unit
• PC for control and analysis (equipped with Microsoft Windows 7)
• Dedicated control and analysis software
• LCD monitor (15 inch)
• Printer for data output (inkjet type)
• Dewar flask (300ml)
• Sample cell (10 pcs)
• Sample injector (100 pcs)
Overview
Macsorb®
Fully automatic BET specific surface area measuring device
Specific surface area measurement, indispensable for evaluating powder characteristics, is becoming increasingly important in quality control due to the micronization and multi-functionalization of powders. At production sites, evaluation of not only raw materials and final products but also intermediate products is required, and the inspection of specific surface area measurements is rapidly increasing. The fully automatic specific surface area measuring device Macsorb enables rapid and high-precision specific surface area measurement by automating all processes, including direct control by PC and pre-treatment. Multi-sample unattended measurement is also possible through combination with a selectable auto sampler tailored to on-site requirements.
1. 1-unit Preheater Unit
Reduced measurement time when using the simple 1-unit Free heat unit Model-1201
2. 8-series Preheater Unit
A 4-continuous x 2-type Free heat unit that further reduces measurement time, allowing 8 samples to be processed at once under the same degassing conditions.
3. Independent 5-series Preheater Unit
A 5-series Free heat unit with independent temperature control that shortens measurement time for samples with different degassing conditions.
4. Gas Switching Unit for Multi-point Measurement
Gas switching unit that enables multi-point measurement with Macsorb
Common Specifications
※Measuring instrument main unit
| Measurement Principle | BET flow method (1-point method/multi-point method option) |
| Measurement Range | 0.01~4000㎡/g (Depends on sample characteristics) |
| Measurement Accuracy | Reproducibility ±1% (Depends on sample) |
| Gas Used | Pure nitrogen and mixed gas (nitrogen 30% + helium 70%) |
| Degassing Temperature | Max 450℃ |
| Approx. 30Kg (measuring instrument main unit only) Dimensions | W310xD600xH570 (measuring instrument main unit only) |
| Weight | Approx. 30Kg (measuring instrument main unit only) |
※Control PC (Company specified model)
| PC Main Unit | PC/AT compatible machine capable of running Windows XP |
| CPU: Conforms to OS requirements (Intel Pentium compatible 1.4GHz or higher recommended) | |
| RAM: 512MB or more recommended | |
| CD-ROM drive required for installing control/analysis software | |
| RS-232C port required for communication with the measuring instrument main unit | |
| Monitor | VGA compatible, XGA or higher recommended |
| Printer | Inkjet (standard) / Laser type |
Specification
| Model | HM Model-1201 | HM Model-1208 | HM Model-1210 | HM Model-1220 | HM Model-1230 |
| Measurement Principle | BET flow method (1-point method / multi-point method) | ||||
| Measurement Range | 0.01~4000㎡/g (Depends on sample characteristics) | ||||
| Measurement Accuracy | Reproducibility ±1% (Depends on sample) | ||||
| Measurement Time | Approx. 10 minutes / 1 sample (excluding pre-treatment) | ||||
| Gas Used | Pure nitrogen and mixed gas (nitrogen 30% + helium 70%) | ||||
| Number of Continuous Automatic Measurement Samples | 1 sample | 8 samples | 10 samples | 20 samples | 30 samples |
| Auto Sampler | - | 8 samples | 10 samples | 20 samples | 30 samples |
| Dimensions (Main unit + AS) | W310xD600xH570 | W610xD750xH570 | W610xD750xH570 | W810xD850xH570 | W930xD900xH570 |
| Power | 100V, 50/60Hz 2A | 100V, 50/60Hz 4A | |||
| Multi-point Measurement | Option | ||||
Detailed specification sheets are shown in the product images.
Surface Area Analyzer (BET) HM Model-1201
Surface Area Analyzer (BET) HM Model-1201: overview and buying guide
The Surface Area Analyzer (BET) HM Model-1201 (model HM Model-1201) is made by SAMBOO SYSTEM and listed in our chemical range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Surface Area Analyzer (BET) HM Model-1201 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Surface Area Analyzer (BET) HM Model-1201 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine SAMBOO SYSTEM product?
We purchase directly from SAMBOO SYSTEM or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
HM Model-1201
Standard 1 sample automatic measurement type
This is the standard and minimum configuration of Macsorb, widely used from research laboratories to production sites.
Once a sample is set, everything from pre-treatment to measurement completion is performed automatically.
After purchase, as usage frequency increases, an auto sampler can be added to expand it into an 8~30 point automatic operation system, and multi-point measurement is also possible with an optional gas switching unit.
Features
• Macsorb main unit
• PC for control and analysis (equipped with Microsoft Windows 7)
• Dedicated control and analysis software
• LCD monitor (15 inch)
• Printer for data output (inkjet type)
• Dewar flask (300ml)
• Sample cell (10 pcs)
• Sample injector (100 pcs)
Overview
Macsorb®
Fully automatic BET specific surface area measuring device
Specific surface area measurement, indispensable for evaluating powder characteristics, is becoming increasingly important in quality control due to the micronization and multi-functionalization of powders. At production sites, evaluation of not only raw materials and final products but also intermediate products is required, and the inspection of specific surface area measurements is rapidly increasing. The fully automatic specific surface area measuring device Macsorb enables rapid and high-precision specific surface area measurement by automating all processes, including direct control by PC and pre-treatment. Multi-sample unattended measurement is also possible through combination with a selectable auto sampler tailored to on-site requirements.
1. 1-unit Preheater Unit
Reduced measurement time when using the simple 1-unit Free heat unit Model-1201
2. 8-series Preheater Unit
A 4-continuous x 2-type Free heat unit that further reduces measurement time, allowing 8 samples to be processed at once under the same degassing conditions.
3. Independent 5-series Preheater Unit
A 5-series Free heat unit with independent temperature control that shortens measurement time for samples with different degassing conditions.
4. Gas Switching Unit for Multi-point Measurement
Gas switching unit that enables multi-point measurement with Macsorb
Common Specifications
※Measuring instrument main unit
| Measurement Principle | BET flow method (1-point method/multi-point method option) |
| Measurement Range | 0.01~4000㎡/g (Depends on sample characteristics) |
| Measurement Accuracy | Reproducibility ±1% (Depends on sample) |
| Gas Used | Pure nitrogen and mixed gas (nitrogen 30% + helium 70%) |
| Degassing Temperature | Max 450℃ |
| Approx. 30Kg (measuring instrument main unit only) Dimensions | W310xD600xH570 (measuring instrument main unit only) |
| Weight | Approx. 30Kg (measuring instrument main unit only) |
※Control PC (Company specified model)
| PC Main Unit | PC/AT compatible machine capable of running Windows XP |
| CPU: Conforms to OS requirements (Intel Pentium compatible 1.4GHz or higher recommended) | |
| RAM: 512MB or more recommended | |
| CD-ROM drive required for installing control/analysis software | |
| RS-232C port required for communication with the measuring instrument main unit | |
| Monitor | VGA compatible, XGA or higher recommended |
| Printer | Inkjet (standard) / Laser type |
Specification
| Model | HM Model-1201 | HM Model-1208 | HM Model-1210 | HM Model-1220 | HM Model-1230 |
| Measurement Principle | BET flow method (1-point method / multi-point method) | ||||
| Measurement Range | 0.01~4000㎡/g (Depends on sample characteristics) | ||||
| Measurement Accuracy | Reproducibility ±1% (Depends on sample) | ||||
| Measurement Time | Approx. 10 minutes / 1 sample (excluding pre-treatment) | ||||
| Gas Used | Pure nitrogen and mixed gas (nitrogen 30% + helium 70%) | ||||
| Number of Continuous Automatic Measurement Samples | 1 sample | 8 samples | 10 samples | 20 samples | 30 samples |
| Auto Sampler | - | 8 samples | 10 samples | 20 samples | 30 samples |
| Dimensions (Main unit + AS) | W310xD600xH570 | W610xD750xH570 | W610xD750xH570 | W810xD850xH570 | W930xD900xH570 |
| Power | 100V, 50/60Hz 2A | 100V, 50/60Hz 4A | |||
| Multi-point Measurement | Option | ||||
Detailed specification sheets are shown in the product images.