{"product_id":"subsea-buoyancy-flowline-buoyancy-38232","title":"Subsea Buoyancy -  Flowline Buoyancy","description":"\u003cp\u003eThere is a growing requirement in deepwater applications for rigid flowlines to perform under high temperature\/high pressure conditions. Large cyclic changes in temperature and pressure cause expansion of the flowline that can result in the occurence of lateral or upheaval buckling. Flowline system engineers therefore need to consider this potentially damaging phenomenon in their analysis and ways of mitigation.\u003c\/p\u003e \u003cp\u003eAn increasingly favourable mitigation solution is to establish spans of least resistance along the flowline to allow buckles to occur in known and controlled conditions. These sections of least resistance can be created via the addition of distributed buoyancy, designed to reduce the self weight of the flowline and friction against the seabed.\u003cbr\u003e \u003cbr\u003e Our extensive buoyancy design experience encompasses the following:\u003cbr\u003e \u003c\/p\u003e \u003cp\u003eㆍOperation at depths up to 7000m \u003cbr\u003e ㆍTower and S-Lay installation methods \u003cbr\u003e ㆍClamping onto thermally insulated pipelines \u003cbr\u003e ㆍAbrasion\/load consideration during installation and service \u003cbr\u003e ㆍBend radii\/stiffness of pipe \u003cbr\u003e ㆍ≈50°C (outer pipe) and storage temperature\u003cbr\u003e ㆍA design life of 25 years and over\u003c\/p\u003e \u003cp\u003eBuoyancy can be applied to the flowline in various forms, for example as half shell modules or as a direct cast-on coating. The decision as to which solution is best suited will depend on thorough consideration of the design parameters as follows:\u003c\/p\u003e \u003cp\u003eㆍBuoyancy requirement per metre and overall length of coverage \u003cbr\u003e ㆍWater depth \u003cbr\u003e ㆍFlowline characteristics - diameter MBR etc. \u003cbr\u003e ㆍFlowline coating characteristics - thickness, contraction, creep, frictional coefficients \u003cbr\u003e ㆍInstallation method - J-Lay or S-Lay \u003cbr\u003e ㆍInstallation and service loads acting upon the buoyancy \u003cbr\u003e ㆍIs the pipe reeled or jointed? \u003cbr\u003e ㆍPipe installation speed \u003cbr\u003e ㆍSeabed conditions - what does the abrasion resistant coating need to withstand? \u003cbr\u003e ㆍNumber of buckling cycles \u003cbr\u003e ㆍAllowable stiffness of flowline - buoyancy is designed to avoid adding unacceptable stiffness to riser \u003cbr\u003e ㆍCorrosion protection \u003cbr\u003e ㆍDesign life \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eAll of our Flowline Buoyancy systems utilise the following materials:\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSyntactic Foam Core\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eThe buoyancy elements of each system have a composite syntactic foam core. This material has three main components:\u003c\/p\u003e \u003cp\u003eㆍBase polymer\u003c\/p\u003e \u003cp\u003eㆍGlass microspheres\u003c\/p\u003e \u003cp\u003eㆍMacrospheres\u003c\/p\u003e \u003cp\u003eThe resulting material exhibits low water absorption and hydrostatic compression and is eminently suitable for extended subsea service. The syntactic foam has a nominal density which varies according to the specific water depth of the application.\u003c\/p\u003e \u003cp\u003eTypical Densities:\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eMSW (m)\u003c\/td\u003e \u003ctd\u003eDensity (kg\/m3)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e200\u003c\/td\u003e \u003ctd\u003e325\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e500\u003c\/td\u003e \u003ctd\u003e420\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e1000\u003c\/td\u003e \u003ctd\u003e480\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e2000\u003c\/td\u003e \u003ctd\u003e500\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e3000\u003c\/td\u003e \u003ctd\u003e530\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eBuoyancy skin\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eThe syntactic foam core is protected from impact and abrasion using a proven skin system that we have developed on our Uraduct® cable and flowline protection products. The principal material components used are Glass Reinforced Plastics (GRP) and high grade polymers. These materials can be adapted to include marine growth and anti-foul protection if required.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eClamps\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eHolding the buoyancy in position on the flowline is critical to the overall flowline system performance. We have several clamping technologies available to use, their selection dependent on the installation and service conditions and the flowline coating properties. These range from carbon steel clamp arrangements, using elastic materials such as titanium, rubber and GRP for insulated flowlines where the outer diameter of the thermal coatings can vary significantly during service.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMetallic Components\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMetallic components materials are selected for both their mechanical performance and resistance to corrosion. Typical materials are Inconel, Super Duplex, Titanium and CP protected carbon steel.\u003c\/p\u003e \u003cp\u003eOur Flowline Buoyancy Systems use steel and aluminium mould tooling processes and are manufactured on our sites in Skelmersdale, UK and Houston, Texas, USA.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eTesting\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eTesting and product development are at the heart of our material advances and product solutions. Whether this be within laboratories, full scale testing or ongoing research and development, testing is a major focal point for us. We believe that continuous and extensive testing is the only way to remain at the forefront of material development and continue to offer solutions that expand production possibilities and improve operating efficiency.\u003c\/p\u003e \u003cp\u003eTesting for our Flowline Buoyancy systems encompasses the following:\u003c\/p\u003e \u003cp\u003eㆍMaterial testing\u003c\/p\u003e \u003cp\u003eㆍFit-up and assembly testing\u003c\/p\u003e \u003cp\u003eㆍLoad testing - axial, lateral and bending\u003c\/p\u003e \u003cp\u003eㆍHydrostatic testing\u003c\/p\u003e \u003cp\u003eㆍAbrasial testing\u003c\/p\u003e \u003cp\u003eㆍWeight and buoyancy measurement\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-5a0e31d1e1d499d9.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlowline Buoyancy Data Sheet\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Shinyang Technology","offers":[{"title":"Default Title","offer_id":58446923596116,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/shinyang-technology_38232_jfdvfb.jpg?v=1795192016","url":"https:\/\/premiumemart.com\/products\/subsea-buoyancy-flowline-buoyancy-38232","provider":"Premium Emart","version":"1.0","type":"link"}