Spectrophotometer - General Model SV1600

Visible General Analysis Type 
SV-1600 & SV-1800 

SV1600 & SV1800 Advance Visible Spectrophotometers

SV1600 & SV1800 are developed for precise tests. The stray lights are less than 0.05%T. They are flexible, easy-to-use and maximize value. The stand-alone built-in software provides functions of Basic Mode, Quantitative Test, Kinetics and System utilities. The only difference between SV1600 and SV1800 is bandwidth. SV1600 is 4nm while SV1800 is 2nm.

Features

Automatically setting the wavelength

Large LCD screen (128 x 64 bits)

Display standard curve and the kinetics curve

Test result can be saved directly to system. The built-in RAM can store 50 groups of data and 10 standard curves.

Convenient for checking and reloading from saved files

Data can be restored after a sudden power cut.

The application software provides complete control of the spectrophotometer from a computer through the built-in USB port.

Pre-Alignment design makes it convenient to change lamps.

Large sample compartment. It can accommodate 5-100mm Pathlength cuvettes with optional cell holders.

A variety of optional accessories are available.

Can upgrade to wavelength scan models when connected to PC via SpectroSoft software based on Windows.

SpectroVisa Visible Spectrophotometer Comparison Chart

Model SV1600 SV1800
 Wavelength Range 320 - 1100 nm 320 - 1100 nm
 Spectral Bandwidth 4 nm 2 nm
 Optical Bandwidth Single Beam
Grating 1200 lines/mm
Single Beam
Grating 1200 lines/mm
 Wavelength Accuracy ±0.5nm ±0.5nm
 Wavelength Repeatability ±0.3nm ±0.3nm
 Wavelength Setting Auto Auto
 Photometric Accuracy ±0.3%T ±0.3%T
 Photometric Repeatability ±0.2%T ±0.2%T
 Photometric Range -0.3A- 3A, 
0 - 200%T
-0.3A- 3A, 
0 - 200%T
 Stray Light 0.05%T@360nm 0.05%T@360nm
 Stability ±0.002A/h 
@ 500nm
±0.002A/h 
@ 500nm
 Display Graphic LCD 
(128 x 64 dots)
Graphic LCD 
(128 x 64 dots)
 Photometric Mode Transmittance
Absorbance
Concentratio
Transmittance
Absorbance
Concentration
 Detector Silicon Photodiode Silicon Photodiode
 Standard Cell Holder 4-Position 10 mm cell holder 4-Position 10 mm cell holder
 Sample Compartment Standard 10 mm Pathlenght Standard 10 mm Pathlenght
 Light Source Halogen Tungsten lamp Halogen Tungsten lamp
 Output USB Port & Parallel Port USB Port & Parallel Port
 Power Requirement 110V/60Hz or 220V/50Hz 110V/60Hz or 220V/50Hz
 Dimensions   (W x D x H) 480 x 370 x 180 mm 480 x 370 x 180 mm
 Weight 14 kg 14 kg

Error product group when enable variant picker

Availability: In stock
Test and Measurement – illustrative image, not the exact model

Spectrophotometer - General Model SV1600

$0.00

Spectrophotometer - General Model SV1600: overview and buying guide

The Spectrophotometer - General Model SV1600 (model SV1600) is made by Human Science and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Spectrophotometer - General Model SV1600 cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Spectrophotometer - General Model SV1600 to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine Human Science product?

We purchase directly from Human Science or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

Visible General Analysis Type 
SV-1600 & SV-1800 

SV1600 & SV1800 Advance Visible Spectrophotometers

SV1600 & SV1800 are developed for precise tests. The stray lights are less than 0.05%T. They are flexible, easy-to-use and maximize value. The stand-alone built-in software provides functions of Basic Mode, Quantitative Test, Kinetics and System utilities. The only difference between SV1600 and SV1800 is bandwidth. SV1600 is 4nm while SV1800 is 2nm.

Features

Automatically setting the wavelength

Large LCD screen (128 x 64 bits)

Display standard curve and the kinetics curve

Test result can be saved directly to system. The built-in RAM can store 50 groups of data and 10 standard curves.

Convenient for checking and reloading from saved files

Data can be restored after a sudden power cut.

The application software provides complete control of the spectrophotometer from a computer through the built-in USB port.

Pre-Alignment design makes it convenient to change lamps.

Large sample compartment. It can accommodate 5-100mm Pathlength cuvettes with optional cell holders.

A variety of optional accessories are available.

Can upgrade to wavelength scan models when connected to PC via SpectroSoft software based on Windows.

SpectroVisa Visible Spectrophotometer Comparison Chart

Model SV1600 SV1800
 Wavelength Range 320 - 1100 nm 320 - 1100 nm
 Spectral Bandwidth 4 nm 2 nm
 Optical Bandwidth Single Beam
Grating 1200 lines/mm
Single Beam
Grating 1200 lines/mm
 Wavelength Accuracy ±0.5nm ±0.5nm
 Wavelength Repeatability ±0.3nm ±0.3nm
 Wavelength Setting Auto Auto
 Photometric Accuracy ±0.3%T ±0.3%T
 Photometric Repeatability ±0.2%T ±0.2%T
 Photometric Range -0.3A- 3A, 
0 - 200%T
-0.3A- 3A, 
0 - 200%T
 Stray Light 0.05%T@360nm 0.05%T@360nm
 Stability ±0.002A/h 
@ 500nm
±0.002A/h 
@ 500nm
 Display Graphic LCD 
(128 x 64 dots)
Graphic LCD 
(128 x 64 dots)
 Photometric Mode Transmittance
Absorbance
Concentratio
Transmittance
Absorbance
Concentration
 Detector Silicon Photodiode Silicon Photodiode
 Standard Cell Holder 4-Position 10 mm cell holder 4-Position 10 mm cell holder
 Sample Compartment Standard 10 mm Pathlenght Standard 10 mm Pathlenght
 Light Source Halogen Tungsten lamp Halogen Tungsten lamp
 Output USB Port & Parallel Port USB Port & Parallel Port
 Power Requirement 110V/60Hz or 220V/50Hz 110V/60Hz or 220V/50Hz
 Dimensions   (W x D x H) 480 x 370 x 180 mm 480 x 370 x 180 mm
 Weight 14 kg 14 kg