{"product_id":"soft-starter-133147","title":"Soft Starter SSCe","description":"\u003cp\u003e\u003cstrong\u003eSoft Starter\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eSoft starter is an effective and economical solution that can guarantee stable operation of motor. With LS's extensive experience and expertise, we provide a way to improve operational effectiveness and minimize energy cost.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e- Easy Operation \u0026amp; Control\u003c\/p\u003e \u003cp\u003e- Motor Protection\u003c\/p\u003e \u003cp\u003e- Built-in bypass\u003c\/p\u003e \u003cp\u003e- Compact Design, Easy to integrate\u003c\/p\u003e \u003cp\u003e- Timed Voltage Ramp System\u003c\/p\u003e \u003cp\u003e- Convenient Status and Trip Check with LED Indicator\u003c\/p\u003e \u003cp\u003e ㆍLV SSC Series (Economic): 200~575Vac 18~200A\u003c\/p\u003e \u003cp\u003e ㆍLV SSM Series (Standard): 200~690Vac 24~1250A\u003c\/p\u003e \u003cp\u003e ㆍLV SSH Series (High Voltage): 2.3~13.8kVac 70~1700A\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003emodel\u003c\/th\u003e \u003cth\u003eSoft\u003cbr\u003eStart\u003c\/th\u003e \u003cth\u003eMotor\u003cbr\u003eProtection\u003c\/th\u003e \u003cth\u003eAdvanced\u003cbr\u003eInterface\u003c\/th\u003e \u003cth\u003eInternal\u003cbr\u003eBypass\u003c\/th\u003e \u003cth\u003eCurrent\u003cbr\u003eRange\u003c\/th\u003e \u003cth\u003eVoltage\u003cbr\u003eRange\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eSSCe\u003c\/th\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e~200 A\u003c\/td\u003e \u003ctd\u003e~575 VAC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSSCi\u003c\/th\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e~200 A\u003c\/td\u003e \u003ctd\u003e~575 VAC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSSM□\u003c\/th\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e~1250 A\u003c\/td\u003e \u003ctd\u003e~690 VAC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSSH\u003c\/th\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e●\u003c\/td\u003e \u003ctd\u003e~1700 A\u003c\/td\u003e \u003ctd\u003e~15kV\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eSSC Series\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eItems\u003c\/th\u003e \u003cth colspan=\"2\"\u003eSpecifications\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth rowspan=\"4\"\u003eMain Supply\u003c\/th\u003e \u003ctd\u003eMain Voltage (L1, L2, L3)\u003cbr\u003e- SSC□-□□□-V4\u003cbr\u003e- SSC□-□□□-V6\u003c\/td\u003e \u003ctd\u003e200~440VAC (+10\/-15%)\u003cbr\u003e200~575VAC (+10\/-15%)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Frequency (at start)\u003c\/td\u003e \u003ctd\u003e45 to 66 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e \u003ctd\u003e600VAC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eForm Designation\u003c\/td\u003e \u003ctd\u003eBypassed, Semiconductor Motor Starter form 1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"5\"\u003eControl Voltage\u003cbr\u003e(A1, A2, A3)\u003c\/th\u003e \u003ctd\u003eSSC□-□□□-□□-C1\u003c\/td\u003e \u003ctd\u003e110~240VAC (+10%\/-15%)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSSC□-□□□-□□-C1\u003c\/td\u003e \u003ctd\u003e380~440VAC (+10%\/-15%)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSSC□-□□□-□□-C2\u003c\/td\u003e \u003ctd\u003e24VAC\/VDC((±20%)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCurrent Consumption (During Run)\u003c\/td\u003e \u003ctd\u003e\u0026lt; 100mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCurrent Consumption (Inrush)\u003cbr\u003e- SSC□-□□□-□□-C1\u003cbr\u003e- SSC□-□□□-□□-C2\u003c\/td\u003e \u003ctd\u003e10A\u003cbr\u003e2A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eInputs\u003c\/th\u003e \u003ctd\u003eStart (Terminal 01)\u003c\/td\u003e \u003ctd\u003eNormally open (150kΩ@300VAC and 5.6kΩ@24VAC\/VDC)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStop (Terminal 02)\u003c\/td\u003e \u003ctd\u003eNormally Closed (150kΩ@300VAC and 5.6kΩ@24VAC\/VDC)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eOutputs\u003c\/th\u003e \u003ctd\u003eMain Contactor\u003cbr\u003e(Terminals 13,14)\u003c\/td\u003e \u003ctd\u003eNormally Open (6A, 30VDC \/ 6A, 250VAC Resistive)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eProgrammable Relay\u003cbr\u003e(Terminals 23,24)\u003c\/td\u003e \u003ctd\u003eNormally Open (6A, 30VDC \/ 6A, 250VAC Resistive)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"7\"\u003eEnvironmental\u003c\/th\u003e \u003ctd\u003eDegree of Protection\u003cbr\u003eSSC□-018 to SSC□-060\u003c\/td\u003e \u003ctd\u003eIP20\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDegree of Protection\u003cbr\u003eSSC□-075 to SSC□-200\u003c\/td\u003e \u003ctd\u003eIP00\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOperating Temperature\u003c\/td\u003e \u003ctd\u003e-10°C to +60°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStorage Temperature\u003c\/td\u003e \u003ctd\u003e-25°C~60°C (to +70°C for Less than 24 Hours)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHumidity\u003c\/td\u003e \u003ctd\u003e5%~95% Relative Humidity\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePollution Degree\u003c\/td\u003e \u003ctd\u003ePollution Degree 3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVibration\u003c\/td\u003e \u003ctd\u003eIEC 60068 Test Fc Sinusoidal\u003cbr\u003e4Hz to 13.2Hz : ±1mm Displacement\u003cbr\u003e13.2Hz to 200Hz : ±0.7g\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"3\"\u003eEMC Emission\u003c\/th\u003e \u003ctd\u003eEquipment Class (EMC)\u003c\/td\u003e \u003ctd\u003eClass B\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eConducted Radio Frequency Emission\u003c\/td\u003e \u003ctd\u003e0.15MHz to 0.5MHZ: \u0026lt;56~46dB (uV)\u003cbr\u003e0.5MHz to 5MHz: \u0026lt;46dB (uV)\u003cbr\u003e5MHz to 30MHz: \u0026lt;50dB (uV)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRadiated Radio Frequency Emission\u003c\/td\u003e \u003ctd\u003e30MHz to 230MHz: \u0026lt;30dB (uV)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"5\"\u003eEEMC Immunity\u003c\/th\u003e \u003ctd\u003eElectrostatic Discharge\u003c\/td\u003e \u003ctd\u003e4kV Contact, 8kV are Discharge\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRadio Frequency Electromagnetic Field\u003c\/td\u003e \u003ctd\u003e0.15MHz to 1000MHz: 140dB(uV)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRated Impulse Withstand Voltage (Fast Transients 5\/50ns)\u003c\/td\u003e \u003ctd\u003e2kV Line to Earth, 1kV Line to Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage Dip and Short Time Interruption\u003c\/td\u003e \u003ctd\u003e100ms (at 40% Nominal Voltage)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHarmonics and Distortion\u003c\/td\u003e \u003ctd\u003eIEC 61000-2-4 (Class 3), EN\/IEC61800-3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eShort Circuit\u003c\/th\u003e \u003ctd\u003eRated Short-circuit Current SSC□-018 to 060\u003c\/td\u003e \u003ctd\u003e5KA*\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRated Short-circuit Current SSC□-075 to 200\u003c\/td\u003e \u003ctd\u003e10KA*\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eHeat Dissipation\u003c\/th\u003e \u003ctd\u003eDuring Start\u003c\/td\u003e \u003ctd\u003e3 watts \/ Ampere\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDuring Run\u003c\/td\u003e \u003ctd\u003e10 Watts Typical\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eOperational Life\u003c\/th\u003e \u003ctd\u003eSSC□-018 to 060\u003c\/td\u003e \u003ctd\u003e1,000,000 Operations\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSSC□-075 to 200\u003c\/td\u003e \u003ctd\u003e30,000 Operations\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e* These short circuit rating are with fuses used as given in the table under ‘Semiconductor Fuses’ section on manual.\u003c\/p\u003e \u003cp\u003eSSM Series\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eItems\u003c\/th\u003e \u003cth colspan=\"2\"\u003eSpecifications\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth rowspan=\"6\"\u003eSupply\u003c\/th\u003e \u003ctd\u003eMain Voltage (L1, L2, L3)\u003cbr\u003e- SSM□-□□□B-V5\u003cbr\u003e- SSM□-□□□B-V7\u003c\/td\u003e \u003ctd\u003e200~525VAC (±10%)\u003cbr\u003e380~690VAC (±10%)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eControl Voltage (A1, A2, A3)\u003cbr\u003e- SSM□-□□□B-□□-C1 (A1, A2)\u003cbr\u003e- SSM□-□□□B-□□-C1 (A2, A3)\u003cbr\u003e- SSM□-□□□B-□□-C2 (A1, A2)\u003c\/td\u003e \u003ctd\u003e110~120VAC (+10%\/-15%), 600mA\u003cbr\u003e220~240VAC (+10%\/-15%), 600mA\u003cbr\u003e24VAC\/VDC((±20%), 2.8A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Frequency\u003c\/td\u003e \u003ctd\u003e50~60Hz (±5Hz)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRated Insulation Voltage to Earth\u003c\/td\u003e \u003ctd\u003e600VAC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e \u003ctd\u003e6KV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eForm Designation\u003c\/td\u003e \u003ctd\u003eBypassed or Continuous, Semiconductor Motor Starter form 1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eShort Circuit\u003cbr\u003eCapability\u003c\/th\u003e \u003ctd\u003eCoordination\u003cbr\u003ewith Semiconductor Fuses\u003c\/td\u003e \u003ctd\u003eType 2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCoordination with HRC Fuses\u003c\/td\u003e \u003ctd\u003eType 1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eElectromagnetic\u003cbr\u003eCapability\u003cbr\u003e(Compliant with\u003cbr\u003eEU Directive\u003cbr\u003e2014\/35\/EU)\u003c\/th\u003e \u003ctd\u003eEMC Immunity\u003c\/td\u003e \u003ctd\u003eIEC 60947-4-2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEMC Emissions\u003c\/td\u003e \u003ctd\u003eNIEC 60947-4-2 Class B\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eInputs\u003c\/th\u003e \u003ctd\u003eInput Rating\u003c\/td\u003e \u003ctd\u003eActive 24VDC, 8mA Approx.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMotor Thermistor (B4, B5)\u003c\/td\u003e \u003ctd\u003eTrip\u0026gt;3.6kΩ, reset\u0026lt;1.6kΩ\u0026lt; \/td\u0026gt;\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eOutputs\u003c\/th\u003e \u003ctd\u003eRelay Outputs\u003cbr\u003e- Main Contactor (33, 34)\u003cbr\u003e- Relay Output A (41, 42, 44)\u003cbr\u003e- Relay Output B (53, 54)\u003c\/td\u003e \u003ctd\u003e10A@250VAC Resistive, 5A@250VAC AC15 pf 0.3\u003cbr\u003eNormally Open\u003cbr\u003eChangeover\u003cbr\u003eNormally Open\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAnalog Output (21, 22)\u003cbr\u003e- Maximum Load\u003cbr\u003e- Accuracy\u003c\/td\u003e \u003ctd\u003e600Ω (12VDC@20mA)\u003cbr\u003e±5%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"7\"\u003eEnvironmental\u003c\/th\u003e \u003ctd\u003eOperating Temperature\u003c\/td\u003e \u003ctd\u003e-10°C~60°C, Above 40°C with Derating\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStorage Temperature\u003c\/td\u003e \u003ctd\u003e-25~+60°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOperating Altitude\u003c\/td\u003e \u003ctd\u003e0~1000m, Above 1000m with Derating\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHumidity\u003c\/td\u003e \u003ctd\u003e5%~95% Relative Humidity\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePollution Degree\u003c\/td\u003e \u003ctd\u003ePollution Degree 3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVibration\u003c\/td\u003e \u003ctd\u003eIEC 60068-2-6\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eProtection\u003cbr\u003e- SSM□-0024B ~ 0135B\u003cbr\u003e- SSM□-0184B ~ 1250B\u003c\/td\u003e \u003ctd\u003eP20\u003cbr\u003eIP00\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eHeat Dissipation\u003c\/th\u003e \u003ctd\u003eDuring Start\u003c\/td\u003e \u003ctd\u003e4.5 Watts per Ampere\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDuring Run\u003cbr\u003e- SSM□-0024B ~ 0052B\u003cbr\u003e- SSM□-0064B ~ 0135B\u003cbr\u003e- SSM□-0184B ~ 0250B\u003cbr\u003e- SSM□-0352B ~ 0580B\u003cbr\u003e- SSM□-0835B ~ 1250B\u003c\/td\u003e \u003ctd\u003e≤ 35 Watts Approx\u003cbr\u003e≤ 50 Watts Approx\u003cbr\u003e≤ 120 Watts Approx\u003cbr\u003e≤ 140 Watts Approx\u003cbr\u003e≤ 180 Watts Approx\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eMotor Overload Protection\u003c\/th\u003e \u003ctd\u003eDefault\u003c\/td\u003e \u003ctd\u003eThe Default Settings of Parameters 1D,\u003cbr\u003e1E and 1F Provide Motor Overload\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eProtection\u003c\/td\u003e \u003ctd\u003eClass 10, Trip Current 105%\u003cbr\u003eof FLA (Full Load Amperage) or Equivalent.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOperational Life\u003c\/th\u003e \u003ctd\u003eOperational Life\u003c\/td\u003e \u003ctd\u003e100,000 Operations\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003eSSH Series\u003c\/p\u003e \u003cp\u003ePanel Rating\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eItems\u003c\/th\u003e \u003cth\u003eSpecifications\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated Voltage\u003c\/th\u003e \u003ctd\u003e3.6kV - 17.5kV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eRated Busbar Current\u003c\/th\u003e \u003ctd\u003eUp to 2000A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eRated short time withstand current \/ Peak\u003c\/th\u003e \u003ctd\u003eUp to 50kA, 3 sec \/ 125kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eInternal arc Fault IAC Classification\u003c\/th\u003e \u003ctd\u003eUp to AFLR 50kA, 1 sec\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003ePartition Classification\u003c\/th\u003e \u003ctd\u003ePM \/PI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eLoss of Service Continuity\u003c\/th\u003e \u003ctd\u003eLSC1 \/ LSC2 \/ LSC2B\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eIP4X protection rating\u003c\/th\u003e \u003ctd\u003eIP4X (IP54 Option)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eAltitude\u003c\/th\u003e \u003ctd\u003e\u0026lt; 1000m (without Reduced Capacity)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eAmbient Temperature\u003c\/th\u003e \u003ctd\u003e-10℃ - 60℃ (Reduced Capacity when Over 50°C)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBasic Panel Color\u003c\/th\u003e \u003ctd\u003eRAL7035 (Additional Option)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003eTechincal Data\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eItems\u003c\/th\u003e \u003cth\u003eSpecifications\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eMotor Voltage\u003c\/th\u003e \u003ctd\u003e2.3-13.8 kV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl Voltage\u003c\/th\u003e \u003ctd\u003e85-264 VAC or 90-350 VDC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eFrequency\u003c\/th\u003e \u003ctd\u003e45\/66 Hz (Autotrigger)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSoft Starter Current\u003c\/th\u003e \u003ctd\u003e70 A - 1700 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eStarting Time (max)\u003c\/th\u003e \u003ctd\u003e1sec – 30sec (180sec)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eAmbient Temperature\u003c\/th\u003e \u003ctd\u003e-10°C ~ 60°C (Reduced Capacity when Exceeding 50°C)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMaximal Altitude\u003c\/th\u003e \u003ctd\u003e1000m (Reduced Capacity when Exceeding 1000m)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eIP (Module type)\u003c\/th\u003e \u003ctd\u003eIP00\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eIP (Controller)\u003c\/th\u003e \u003ctd\u003eUp to IP54\/NEMA12\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOverload Capacity\u003c\/th\u003e \u003ctd\u003eUp to 600% for 120sec\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003ePT Type\u003c\/th\u003e \u003ctd\u003eEPT Type\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCT Type\u003c\/th\u003e \u003ctd\u003eHigh-voltage CT (Primary Current Based on the Motor; secondary 1A)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMV\/LV Separation\u003c\/th\u003e \u003ctd\u003e100% Optical Cable Connection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eDigital Input\u003c\/th\u003e \u003ctd\u003e3 Fixed Values (Start, Stop and Reset) 2 Settable Values (A and B)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eRelay Output\u003c\/th\u003e \u003ctd\u003e4 Fixed Values (Line, Bypass, PFC and PAPS) 3 Settable Values (A, B and C)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eAnalog Output\u003c\/th\u003e \u003ctd\u003e1 Analog Output (4-20mA)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eFieldbus Communication\u003c\/th\u003e \u003ctd\u003eModbus RTU, Modbus TCP, Profibus, Profinet, DeviceNet, Ethernet\/IP, USB, IEC61850\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-5d5a63ba24a9a116.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-LS ELECTRIC-Medium Voltage VFD-Factory Automation Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-b9f6d178e6d83d8d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-LS ELECTRIC-Medium Voltage VFD-Soft Starter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-ec8eda8cbe122475\" target=\"_blank\" rel=\"noopener\"\u003eUser Manual-LS ELECTRIC-Medium Voltage VFD-Soft Starter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-d218c896a24c17a2\" target=\"_blank\" rel=\"noopener\"\u003eManual-LS ELECTRIC-Medium Voltage VFD-Soft Starter\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LS ELECTRIC","offers":[{"title":"Default Title","offer_id":58446628913492,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/48d82497-4dd4-480e-af40-2e525a31efcc.jpg?v=1795191347","url":"https:\/\/premiumemart.com\/products\/soft-starter-133147","provider":"Premium Emart","version":"1.0","type":"link"}