{"product_id":"smart-power-regulator-12153","title":"SMART Power Regulator","description":"\u003cp\u003e- SMART digital power regulator is next generation regulator adopting all technologies and know-how’s PARA-ENT has accumulated since its establishment of 2000.\u003c\/p\u003e \u003cp\u003e- Through MPD(Max Power Distribution) function, SMART power regulator can improve power factor and optimize efficiency of power by lowering peak power.\u003c\/p\u003e \u003cp\u003e- Designed to meet any customer’s requirements with ease and convenience.\u003cbr\u003e \u003cbr\u003e \u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003e﻿SMART MPD (Max Power Distribution) Function\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e1) Improving power factor\u003c\/p\u003e\u003cp\u003e- Distributing momentary maximum output power by sequential control through synchronization, when multiple power regulators are operated at the same time.\u003c\/p\u003e\u003cp\u003e- Sinusoidal waves in main power are as below.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSMART PLF (Partial Load Failure)\u003cb\u003e(Patent REG. NO 10-1405243 Power supply control apparatus having partial load disconnection detector and method for detecting partial load disconnection using the same\u003c\/b\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e- To detect partial load failure in multiple parallel loads.\u003c\/p\u003e\u003cp\u003e- To realize detecting partial load failure immediately and precisely through PARA-ENT its own unique auto-tuning function.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSMART DISPLAY (PARA SMART DISPLAY )\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e- Improve user’s interface by color LCD and 18 keypad.\u003c\/p\u003e\u003cp\u003e- Easy and convenient key function with self diagnosis and test mode.\u003c\/p\u003e\u003cp\u003e- PSD can be detachable from SMC (Smart Main Controller) and attachable on the surface of panel for better visibility.\u003c\/p\u003e\u003cp\u003e- Displaying ongoing voltage\/current\/power\/resistance of load (temperature of heatsink, 4th parameter can be selectable between resistance of load or temperature of heatsink)\u003c\/p\u003e\u003cp\u003e- Displaying input signal and output by bar graph for easy recognition\u003c\/p\u003e\u003cp\u003e- PSD can be detachable from SMC and attachable onto SMC(Smart Main Controller). When PSD is installed on the surface of panel, no need to install panel meters like current meter and voltage meter because PSD shows these parameters.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSMART COMBINATION\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e- With one SMC, maximum three PM’s (Power Module) can be attachable. Designed to combine SMC and PM’s to user’s requirement.\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\u003cli\u003eOne single phase\u003c\/li\u003e\u003c\/ul\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003eTwo single-phase\u003c\/li\u003e\n\u003cli\u003eOne single phase controlling both phases\u003c\/li\u003e\n\u003cli\u003eThree phase two legs (Only on zero-crossing control)\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003eFor stability\u003c\/li\u003e\n\u003cli\u003eFor economical reason\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003eThree single phase\u003c\/li\u003e\n\u003cli\u003eThree phase four wire system\u003c\/li\u003e\n\u003cli\u003eOne three phase (Delta or Wye wiring)\u003c\/li\u003e\n\u003cli\u003eOpen delta wiring\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\u003cli\u003eThree different input signals or one single input signal can be used for single phase usage.\u003c\/li\u003e\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cb\u003e\u003c\/b\u003e\u003cp\u003e\u003cb\u003eSMART COMBINATION\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e- User can select each alarm condition and alarm relay among three relays.\u003c\/p\u003e\u003cp\u003e- User can select output to continue or stop on alarming status.\u003c\/p\u003e\u003cp\u003e- Cooling fan is working on user’s designated temperature of heatsink for long lifetime.\u003c\/p\u003e\u003cp\u003e- User can select warning or alarm temperature of heatsink\u003c\/p\u003e\u003cp\u003e- Alarm\u003c\/p\u003e\u003cp\u003e① Over current ② Fuse failure ③ Load failure ④ Over temperature ⑤ SCR failure ⑥ Unbalanced load ⑦ Main power failure\u003cbr\u003e⑧ FAN disorder alarm ⑨ Frequency noise alarm ⑩ PLF(Partial Load Failure)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSMART CPU\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e- Powerful 32Bit CPU(12Bit ADC) for high speed and performance.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSMART SELF-DIAGNOSIS\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e- Self diagnosis to check parameter setting, alarm setting and all the wiring status for user’s convenience.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSMART TEST\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e- When actual load is hardly tested, user can test with small load allowing output arbitrarily.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSMART COMMUNICATION\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e- Method : RS-485 2 Wire half-duplex\u003c\/p\u003e\u003cp\u003e- Baud rate : 4800, 9600, 19200, 38400, 57600, Max. 115200bps\u003c\/p\u003e\u003cp\u003e- Max. connectable unit : Max. 32 SMC.\u003c\/p\u003e\u003cp\u003e- Protocol : Modbus-RTU Protocol\u003c\/p\u003e\u003cp\u003e- Read and write available\u003c\/p\u003e\u003cp\u003e- Supplying user’s interface\u003c\/p\u003e\u003cp\u003eOrdering Code\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e① Control method\u003c\/th\u003e\n\u003cth\u003e② Wiring\u003c\/th\u003e\n\u003cth\u003e③ Option\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eSMC\u003cbr\u003e(Smart Main Controller)\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003ePA : Standard phase-angle\u003c\/li\u003e\n\u003cli\u003ePI : Current feedback\u003c\/li\u003e\n\u003cli\u003ePV : Voltage feedback\u003c\/li\u003e\n\u003cli\u003ePW : Power feedback\u003c\/li\u003e\n\u003cli\u003eZC : Zero-crossing\u003c\/li\u003e\n\u003cli\u003ePZ : Mixed mode (PZM)\u003c\/li\u003e\n\u003cli\u003e※ PA(Standard phase-angle is default\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003e1P1L\u003c\/li\u003e\n\u003cli\u003e1P2L\u003c\/li\u003e\n\u003cli\u003e1P3L\u003c\/li\u003e\n\u003cli\u003e2P2L\u003c\/li\u003e\n\u003cli\u003e3P2L\u003c\/li\u003e\n\u003cli\u003e3P3L\u003c\/li\u003e\n\u003cli\u003e3P4L\u003c\/li\u003e\n\u003cli\u003e3P6L\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003ctd\u003eC : Communication\u003cbr\u003eS : PSD detachable\u003cbr\u003e(D-SUB cable 5M)\u003cbr\u003eMPD : Max Power Distribution\u003cbr\u003ePSD2 : PSD-2000\u003cbr\u003e1R : Analogue Output (1CH)\u003cbr\u003e3R : Analogue Output (3CH)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003ctable class=\"pem-spec\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e① Rated voltage\u003c\/th\u003e\n\u003cth\u003e② Rated current\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003ePM(Power Module)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e110V\u003c\/li\u003e\n\u003cli\u003e220V\u003c\/li\u003e\n\u003cli\u003e380V\u003c\/li\u003e\n\u003cli\u003e440V\u003c\/li\u003e\n\u003c\/ul\u003e※ Other than above, please consult us.\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003e10A ~ 2500A\u003c\/li\u003e\n\u003cli\u003e(1000A = 10K)\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cbr\u003e\u003cp\u003e\u003cb\u003ePSD-2000: Wide Display LOOK WIDER: PSD-2000\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003cth\u003e110V \/ 220V \/ 380V \/ 440V\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowance of voltage\u003c\/td\u003e\n\u003ctd\u003e±10% of rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e10A ~ 2500A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz (Auto selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum load\u003c\/td\u003e\n\u003ctd\u003e1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput range\u003c\/td\u003e\n\u003ctd\u003ePhase-angle, Zero-crossing : 0~99.8 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB power\u003c\/td\u003e\n\u003ctd\u003eDC 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 15W (Without fan)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput signal\u003c\/td\u003e\n\u003ctd\u003e4~20mA 3CH \/ 0~5V, 1~5V, 0~10V, 10K VOL (Select) 1CH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital input\u003c\/td\u003e\n\u003ctd\u003eSwitch Input 3CH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital output\u003c\/td\u003e\n\u003ctd\u003eRelay Out 6CH (Alarm 3CH, Fan Control 3CH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl method\u003c\/td\u003e\n\u003ctd\u003ePhase-Angle(Standard, current F\/B, voltage F\/B, power F\/B)\u003cbr\u003eand Zero-Crossing (MPD Function : Option), PZ mixed mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand voltage\u003c\/td\u003e\n\u003ctd\u003eAC3KV (Step 1Min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003eMore than 10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eLess than 55A : Natural cooling \/ More than 70A Cooling fan basically installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003eOver Current, Over Temperature of heatsink(60℃, 80℃), Fuse failure, Load Failure, SCR failure Main power failure, FAN alarm, Partial load failure. Unbalanced load, Frequency noise alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temp\u003c\/td\u003e\n\u003ctd\u003e0 ~ 40℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e30% ~ 90% RH (No condensation )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003e32Bit CPU (12Bit ADC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePM\u003c\/td\u003e\n\u003ctd\u003eOutput voltage \/ Output current : RMS value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePSD\u003c\/td\u003e\n\u003ctd\u003eColor LCD , 18Key Pad (Detachable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-485 2 Wire half-duplex method, Max. 115,000bps Max. 32 SMC’s connectable, Protocol Modbus-RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e","brand":"PARA ENT","offers":[{"title":"Default Title","offer_id":58446839349588,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/paratec_12153_bhqmzp.jpg?v=1795191855","url":"https:\/\/premiumemart.com\/products\/smart-power-regulator-12153","provider":"Premium Emart","version":"1.0","type":"link"}