{"product_id":"silicone-insulated-constant-wattage-heating-cable-37795","title":"Silicone-insulated constant wattage heating cable YKH-101","description":"\u003cdiv\u003e \u003cp\u003e\u003cstrong\u003e1. Description\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eConstant Wattage Heating Cable is ideally suited for applications where a particular watt density is required at all times. As their name suggests, constant wattage heating cables are designed to deliver the same power output irrespective of pipe temperature. Constant Wattage Heating Cable has a parallel circuit construction and provides uniform wattage regardless of temperature. We normally supply Heating Calbes with a braid and outer jacket but cables can also be supplied with just a braid. This conctant wattage heating cable is flexible at most ambient temperatures and can be wrapped around piping and complex fittings.\u003c\/p\u003e \u003cp\u003eConstant Wattage heating cable can be used for a wide variety of applications including freeze protection of pipework and vessels and process temperature maintenance. Also we supply two types of constant wattage heating cable ; the general for low wattage and the industrial for high wattage.\u003cbr\u003e Constant Wattage heating cable is highly flexible and withstand at Max. 250°c. Although not suited for overlapping, its constant output makes it an ideal choice for higher temperature applications where higher watt densities are required.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e2. Specificaton\u003c\/strong\u003e\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e Usage Length 100cm \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Usage Temperature -60°c ~ 200°c \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Voltage 110V \/ 220V \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Wattage 30 W\/m, 40 W\/m, 50 W\/m \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Bus wire 1.25 SQ \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e Packing Unit 100 m \/roll \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003e3. Cable Construction\u003c\/strong\u003e \u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eModel\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eNo.\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eConstruction\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eMaterial\u003c\/strong\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"4\"\u003e \u003cstrong\u003eBare type\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e 1 \u003c\/td\u003e \u003ctd\u003e Bus Wire \u003c\/td\u003e \u003ctd\u003e Tinned Copper \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e 2 \u003c\/td\u003e \u003ctd\u003e 1st Insulation \u003c\/td\u003e \u003ctd\u003e Silicone Rubber \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e 3 \u003c\/td\u003e \u003ctd\u003e Heating Material \u003c\/td\u003e \u003ctd\u003e Cross winding of Nichrome \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e 4 \u003c\/td\u003e \u003ctd\u003e 2nd Insulation \u003c\/td\u003e \u003ctd\u003e Silicone Rubber \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003e \u003cstrong\u003eCR \/ CX type\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e 5 \u003c\/td\u003e \u003ctd\u003e Earth \/ Reinforcement \u003c\/td\u003e \u003ctd\u003e Tinned Copper \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e 6 \u003c\/td\u003e \u003ctd\u003e Outer Insulation \u003c\/td\u003e \u003ctd\u003e Silicone Rubber or Fluoro Resin \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003e4. Cable Model \u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e1) \u003c\/strong\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003e\u003c\/td\u003e \u003ctd colspan=\"5\"\u003e \u003cstrong\u003eWattage per meter\u003c\/strong\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003e10w\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003e20w\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003e30w\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003e40w\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003e50w\u003c\/strong\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eBare\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e YKH10 \u003c\/td\u003e \u003ctd\u003e YKH20 \u003c\/td\u003e \u003ctd\u003e YKH30 \u003c\/td\u003e \u003ctd\u003e YKH40 \u003c\/td\u003e \u003ctd\u003e YKH50 \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eCR\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e YKH10-CR \u003c\/td\u003e \u003ctd\u003e YKH20-CR \u003c\/td\u003e \u003ctd\u003e YKH30-CR \u003c\/td\u003e \u003ctd\u003e YKH40-CR \u003c\/td\u003e \u003ctd\u003e YKH50-CR \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eCRS\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e YKH10-CRS \u003c\/td\u003e \u003ctd\u003e YKH20-CRS \u003c\/td\u003e \u003ctd\u003e YKH40-CRS \u003c\/td\u003e \u003ctd\u003e YKH40-CRS \u003c\/td\u003e \u003ctd\u003e YKH50-CRS \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003e2) \u003c\/strong\u003e\u003cstrong\u003eExplosion-proof\u003c\/strong\u003e\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003e\u003c\/td\u003e \u003ctd colspan=\"5\"\u003e \u003cstrong\u003eWattage per meter\u003c\/strong\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003e10w\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003e20w\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003e30w\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003e40w\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003e50w\u003c\/strong\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eBare\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e KHX10 \u003c\/td\u003e \u003ctd\u003e KHX20 \u003c\/td\u003e \u003ctd\u003e KHX30 \u003c\/td\u003e \u003ctd\u003e KHX40 \u003c\/td\u003e \u003ctd\u003e KHX50 \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eCR\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e KHX10-CR \u003c\/td\u003e \u003ctd\u003e KHX20-CR \u003c\/td\u003e \u003ctd\u003e KHX30-CR \u003c\/td\u003e \u003ctd\u003e KHX40-CR \u003c\/td\u003e \u003ctd\u003e KHX50-CR \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eCRS\u003c\/strong\u003e \u003c\/td\u003e \u003ctd\u003e KHX10-CRS \u003c\/td\u003e \u003ctd\u003e KHX20-CRS \u003c\/td\u003e \u003ctd\u003e KHX40-CRS \u003c\/td\u003e \u003ctd\u003e KHX40-CRS \u003c\/td\u003e \u003ctd\u003e KHX50-CRS \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003e5. Cable installation \u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e(Straight run) \u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eWith a single straight run, position cable at the bottom of a horizontal pipe. All parts of heating cable must make intimate contact\u003c\/p\u003e \u003cp\u003ewith surface to be heated. Use heat conductive putty to fill voids between cable and pipe surface. Wrap adhesive tape every\u003c\/p\u003e \u003cp\u003e12” (305mm) around heating cable and pipe to attach the cable.\u003c\/p\u003e \u003cp\u003eMinimum insulation resistance acceptable after the system has been installed and thermally insulated: The measurement made by applying 500Vdc between each circuit and ground with the set de-energized and all circuit neutrals isolated from ground.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e(Spiral wrapping) \u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eVerify the pitch length (see illustration) prior to installation to ensure you have enough heating cable to finish the job. If you need assistance in determining the pitch length, call your local distributor or All parts of heating cable must make intimate contact with surface to be heated. Use heat conductive putty to fill voids between cable and pipe surface.\u003c\/p\u003e \u003cp\u003eWrap adhesive tape every 12” (305mm) around heating cable and pipe to attach the cable. Minimum insulation resistance acceptable after the system has been installed and thermally insulated: The measurement made by applying 500Vdc between each circuit and ground with the set de-energized and all circuit neutrals isolated from ground.\u003c\/p\u003e \u003c\/div\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e","brand":"YOUNG CHANG","offers":[{"title":"Default Title","offer_id":58446121206100,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/4f76cf5c-8cb7-4b5e-8fe2-b6cd9008cc81.png?v=1795190050","url":"https:\/\/premiumemart.com\/products\/silicone-insulated-constant-wattage-heating-cable-37795","provider":"Premium Emart","version":"1.0","type":"link"}