Signal Converter (Multi) SCONI-2000
Feature
Multi-input, T/C, RTD, Volt, mA, etc
You can get a signal.
High-performance, high-precision 16 Bit A/D Converter
It has been used to improve reliability.
It has a variety of features, including peak hold
It can be used for many purposes.
It can be equipped with RS485 ModBus communication function
It is convenient to use and can be remotely monitored and controlled.
Two outputs can be installed, including current and voltage, and individual
Output Scaling is possible.
Simply check the input and output signals in Mode
You will be given the ability to do so by default.
Main Functions
Input/Output Data Check
This function allows checking the input and output values (0–100%) at any time with a simple Mode Key, without the need for a tester.Display Scaling Function (mV, Volt, mA Type)
This function allows changing the display (PV) value according to the scale and input range.Sensor Compensation Function
If the zero point shifts due to long-term sensor use or if measurement errors occur due to long sensor wiring, this function allows adding or subtracting correction values to the measured values.-
Function (mV, Volt, mA Type)
Limit: Displays “0” when the input signal is disconnected
Linear: Allows display of values below “–”
Root Square: Outputs by applying “√” to the output value
Square Root: Removes “√” from the input value and displays the result
Filter Function
Options: None (Fast), 4, 8, 16, 32
Enables adjustment for field response speed and noise.Communication Function
Equipped with RS485 (ModBus) communication, enabling remote monitoring via computer.Output Scaling Function
Changes the output value (current or voltage) according to the scaling settings.High/Low Peak Check for Input
Allows monitoring of high and low peaks for input signals.External Hold and Reset Function (Option)
Provides external hold and reset functions.High/Low Peak Setting for Present Value
Enables setting of high and low peak values for the current reading.
Detailed specification sheets are shown in the product images.
Signal Converter (Multi) SCONI-2000
Signal Converter (Multi) SCONI-2000: overview and buying guide
The Signal Converter (Multi) SCONI-2000 (model SCONI-2000) is made by ENSCON and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Signal Converter (Multi) SCONI-2000 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Signal Converter (Multi) SCONI-2000 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine ENSCON product?
We purchase directly from ENSCON or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Feature
Multi-input, T/C, RTD, Volt, mA, etc
You can get a signal.
High-performance, high-precision 16 Bit A/D Converter
It has been used to improve reliability.
It has a variety of features, including peak hold
It can be used for many purposes.
It can be equipped with RS485 ModBus communication function
It is convenient to use and can be remotely monitored and controlled.
Two outputs can be installed, including current and voltage, and individual
Output Scaling is possible.
Simply check the input and output signals in Mode
You will be given the ability to do so by default.
Main Functions
Input/Output Data Check
This function allows checking the input and output values (0–100%) at any time with a simple Mode Key, without the need for a tester.Display Scaling Function (mV, Volt, mA Type)
This function allows changing the display (PV) value according to the scale and input range.Sensor Compensation Function
If the zero point shifts due to long-term sensor use or if measurement errors occur due to long sensor wiring, this function allows adding or subtracting correction values to the measured values.-
Function (mV, Volt, mA Type)
Limit: Displays “0” when the input signal is disconnected
Linear: Allows display of values below “–”
Root Square: Outputs by applying “√” to the output value
Square Root: Removes “√” from the input value and displays the result
Filter Function
Options: None (Fast), 4, 8, 16, 32
Enables adjustment for field response speed and noise.Communication Function
Equipped with RS485 (ModBus) communication, enabling remote monitoring via computer.Output Scaling Function
Changes the output value (current or voltage) according to the scaling settings.High/Low Peak Check for Input
Allows monitoring of high and low peaks for input signals.External Hold and Reset Function (Option)
Provides external hold and reset functions.High/Low Peak Setting for Present Value
Enables setting of high and low peak values for the current reading.
Detailed specification sheets are shown in the product images.