Sensaras PLS9600 Series
The Ultrasonic Point Level System 9600 Series is designed to detect the level of Ultrs-Pure Liquid Chemical in Bubblers and Ampoules in the Semiconductor industry in PVD, CVD and ALD processes. The probe fits in the ½" or ¾" VCR fill port of the ampoules. There are no moving parts to the probe that may introduce impurities. It is not dependent on the color, dielectric, density and viscosity of the chemical. The design allows for multiple sensing points. All wetted parts of the probe is 316SS, electropolish finish and leak tested. Each probe is custom made to user's specifications and requirements.
The electronics are remotely mounted from the probes to allow for higher temperature applications. There is no calibration or adjustments between sensors.
Probe Design Features
- Material : Tube or Fork 316LSS
- W-Probe 4 or 8 points on 0.375" OD tube with 0.21" ID-½"VCR
- W-Probe 4 or 8 points on 0.562" OD tube with 0.31" ID-¾"VCR
- M-Probe 4 point on 0.562" OD tube for low level - ¾"VCR
- Temperature : -20 to 120 ℃
- Pressure : 250 PSIG
- Repeatability : Typical ±0.05"
- Lowest Sensing Point on probe : 0.20"
- Minimum distance between point : 0.20"
- Finish : Elector-polished / 10u Ra Surface
- Cable : 2' long integral or remote
- Optional : K-type Thermocouple
Electronic Module Design Features
- Input : 24VDC
- Output : 1A SPDT with LED Display
- Additional Fault relay output / sensor disconnect
- Additional Auto fill / empty output
- Sensor disconnect
- Optional : 90 to 240VDC power supply
- Optional : K-Type Thermocouple display
- Remot / Integral / Custom Electronics
- Molded Cable Extension
Catalogues
Sensaras PLS9600 Series
Sensaras PLS9600 Series: overview and buying guide
The Sensaras PLS9600 Series (model PLS9600 Series) is made by M&C ENGINEERING and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Sensaras PLS9600 Series cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Sensaras PLS9600 Series to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine M&C ENGINEERING product?
We purchase directly from M&C ENGINEERING or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
The Ultrasonic Point Level System 9600 Series is designed to detect the level of Ultrs-Pure Liquid Chemical in Bubblers and Ampoules in the Semiconductor industry in PVD, CVD and ALD processes. The probe fits in the ½" or ¾" VCR fill port of the ampoules. There are no moving parts to the probe that may introduce impurities. It is not dependent on the color, dielectric, density and viscosity of the chemical. The design allows for multiple sensing points. All wetted parts of the probe is 316SS, electropolish finish and leak tested. Each probe is custom made to user's specifications and requirements.
The electronics are remotely mounted from the probes to allow for higher temperature applications. There is no calibration or adjustments between sensors.
Probe Design Features
- Material : Tube or Fork 316LSS
- W-Probe 4 or 8 points on 0.375" OD tube with 0.21" ID-½"VCR
- W-Probe 4 or 8 points on 0.562" OD tube with 0.31" ID-¾"VCR
- M-Probe 4 point on 0.562" OD tube for low level - ¾"VCR
- Temperature : -20 to 120 ℃
- Pressure : 250 PSIG
- Repeatability : Typical ±0.05"
- Lowest Sensing Point on probe : 0.20"
- Minimum distance between point : 0.20"
- Finish : Elector-polished / 10u Ra Surface
- Cable : 2' long integral or remote
- Optional : K-type Thermocouple
Electronic Module Design Features
- Input : 24VDC
- Output : 1A SPDT with LED Display
- Additional Fault relay output / sensor disconnect
- Additional Auto fill / empty output
- Sensor disconnect
- Optional : 90 to 240VDC power supply
- Optional : K-Type Thermocouple display
- Remot / Integral / Custom Electronics
- Molded Cable Extension