HRB-1302, HRB-1302MP, HRB-1402, HRB-1402MP, HRB-1502, HRB-1502MP, HRB-1602, HRB-1602MP  Three Phase [3Ø]

- The allowable Tolerance of dimension is ± 5mm.
- The dimension can be changed for improvement without notice

Performance & Specifications

The blower with the name suffix MH (Motor High-efficiency) is designed to run at 60Hz. 

HRB-1302MP HRB-1302 HRB-1402MP HRB-1402 HRB-1502MP HRB-1502 HRB-1602MP HRB-1602
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
PHASE 3 3 3 3 3 3 3 3

MOTOR
HP - 20.7 17.5 20.4 - 24.7 20.7 24.7 - 34.4 29.3 35.7 - 40.0 33.0 40.0
Kw - 15.5 13.0 15.3 - 18.5 15.5 18.5 - 25.8 22.0 26.8 - 30.0 25.0 30.0
PRESSURE mmAq - 2500 2200 2500 - 3500 3000 3500 - 4800 4800 4800 - 5500 5500 5500

VACUUM
mmAq - 2700 2500 2700 - 3200 3000 3200 - 4800 4500 4800 - 5000 5000 5000

MAX .AIR FLOW
㎥/min - 22.0 17.5 22.0 - 22.0 17.5 22.0 - 22.0 17.5 22.0 - 22.0 17.5 22.0
CURRENT 220V A - 49.4 54.0 54.0 - 59.8 65.5 65.5 - 80.0 76.0 82.0 - 88.2 86.0 86.6
380V A - 28.5 31.2 31.2 - 34.5 37.5 37.5 - 46.0 43.9 47.3 - 51.0 51.6 50.0
SOUND LEVEL dB(A) 88 88 88 88 88 88 88 88
MATERIAL IMPELLER Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum
CASING Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron
BEARING FRONT 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3
MIDDLE - - - - - - - -
REAR 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3

WEIGHT
Kg 330 330 345 345 345 355 365 365

STARTING CLASS
H H H H H H H H

INSULATION CLASS
F F F F F F F F


- The performances above were measured under conditions of air temperature 20 °C and atmospheric pressure 1,013mbar.
- The allowable tolerance of the performance value is +10%
- The sound level was measured at a distance of 1.5m with the fully open inlet and outlet ports.
-  Anti-corrosive and explosion-proof treatments can be applied upon request.

Performance Curve

- The continuous operation can be made at a point below the curve, however, the continuous operation nearby the rated pressure point may cause a motor breakdown. 

   In the case of the continuous operation close to the rated pressure, it is strongly recommended to use the pressure-relief valve. See accessories, page 61.

- The allowable tolerance of the performance value is ± 10%

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
RING BLOWER HRB-1302

RING BLOWER HRB-1302

$0.00

RING BLOWER HRB-1302: overview and buying guide

The RING BLOWER HRB-1302 (model HRB-1302) is made by HWANG HAE ELECTRIC and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the RING BLOWER HRB-1302 cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the RING BLOWER HRB-1302 to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine HWANG HAE ELECTRIC product?

We purchase directly from HWANG HAE ELECTRIC or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

HRB-1302, HRB-1302MP, HRB-1402, HRB-1402MP, HRB-1502, HRB-1502MP, HRB-1602, HRB-1602MP  Three Phase [3Ø]

- The allowable Tolerance of dimension is ± 5mm.
- The dimension can be changed for improvement without notice

Performance & Specifications

The blower with the name suffix MH (Motor High-efficiency) is designed to run at 60Hz. 

HRB-1302MP HRB-1302 HRB-1402MP HRB-1402 HRB-1502MP HRB-1502 HRB-1602MP HRB-1602
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
PHASE 3 3 3 3 3 3 3 3

MOTOR
HP - 20.7 17.5 20.4 - 24.7 20.7 24.7 - 34.4 29.3 35.7 - 40.0 33.0 40.0
Kw - 15.5 13.0 15.3 - 18.5 15.5 18.5 - 25.8 22.0 26.8 - 30.0 25.0 30.0
PRESSURE mmAq - 2500 2200 2500 - 3500 3000 3500 - 4800 4800 4800 - 5500 5500 5500

VACUUM
mmAq - 2700 2500 2700 - 3200 3000 3200 - 4800 4500 4800 - 5000 5000 5000

MAX .AIR FLOW
㎥/min - 22.0 17.5 22.0 - 22.0 17.5 22.0 - 22.0 17.5 22.0 - 22.0 17.5 22.0
CURRENT 220V A - 49.4 54.0 54.0 - 59.8 65.5 65.5 - 80.0 76.0 82.0 - 88.2 86.0 86.6
380V A - 28.5 31.2 31.2 - 34.5 37.5 37.5 - 46.0 43.9 47.3 - 51.0 51.6 50.0
SOUND LEVEL dB(A) 88 88 88 88 88 88 88 88
MATERIAL IMPELLER Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum
CASING Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron
BEARING FRONT 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3
MIDDLE - - - - - - - -
REAR 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3 6308ZC3

WEIGHT
Kg 330 330 345 345 345 355 365 365

STARTING CLASS
H H H H H H H H

INSULATION CLASS
F F F F F F F F


- The performances above were measured under conditions of air temperature 20 °C and atmospheric pressure 1,013mbar.
- The allowable tolerance of the performance value is +10%
- The sound level was measured at a distance of 1.5m with the fully open inlet and outlet ports.
-  Anti-corrosive and explosion-proof treatments can be applied upon request.

Performance Curve

- The continuous operation can be made at a point below the curve, however, the continuous operation nearby the rated pressure point may cause a motor breakdown. 

   In the case of the continuous operation close to the rated pressure, it is strongly recommended to use the pressure-relief valve. See accessories, page 61.

- The allowable tolerance of the performance value is ± 10%

Detailed specification sheets are shown in the product images.