This digital reclosing relay (GD1-K01) is a digital automatic reclosing relay used to perform reclosing up to 4 times to minimize power supply interruption time when the circuit is opened due to temporary faults such as lightning flashovers between phases, between insulators, and between phase and ground, which constitute most faults occurring in power systems, thereby improving the power reliability of the system.

Main Specifications


Operating Characteristics


Measurement Functions

● Stores circuit breaker trip count during fault (max 65535), includes Clear function

● Instantaneous Trip Inhibit function is disabled after the set number of reclosures is completed

● If the circuit breaker trips within 0.5 seconds before closing during reclosing operation, reclosing is not performed

  - If the final reclosing fails, a Fail Signal is output

  - If it is not the final reclosing, closing is attempted during the next reclosing

● Selectively use 79S/79P (terminal number 12)

  - 79S: Contact that operates when reclosing is started with 79Start

  - 79P: Contact that operates when reclosing preparation conditions are met

● The Discrimination Time function is the time to check if the circuit breaker has actually closed during reclosing. It checks for the set time, and if the circuit breaker is not closed, a Fail Signal is output.

  - If set to 0, this function is not used


External Connection


Dimensions

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
Categories: Electronic
Reclosing Relay GD1-K01

Reclosing Relay GD1-K01

$0.00

Reclosing Relay GD1-K01: overview and buying guide

The Reclosing Relay GD1-K01 (model GD1-K01) is made by KYONGBO ELECTRIC and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Reclosing Relay GD1-K01 cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Reclosing Relay GD1-K01 to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine KYONGBO ELECTRIC product?

We purchase directly from KYONGBO ELECTRIC or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

This digital reclosing relay (GD1-K01) is a digital automatic reclosing relay used to perform reclosing up to 4 times to minimize power supply interruption time when the circuit is opened due to temporary faults such as lightning flashovers between phases, between insulators, and between phase and ground, which constitute most faults occurring in power systems, thereby improving the power reliability of the system.

Main Specifications


Operating Characteristics


Measurement Functions

● Stores circuit breaker trip count during fault (max 65535), includes Clear function

● Instantaneous Trip Inhibit function is disabled after the set number of reclosures is completed

● If the circuit breaker trips within 0.5 seconds before closing during reclosing operation, reclosing is not performed

  - If the final reclosing fails, a Fail Signal is output

  - If it is not the final reclosing, closing is attempted during the next reclosing

● Selectively use 79S/79P (terminal number 12)

  - 79S: Contact that operates when reclosing is started with 79Start

  - 79P: Contact that operates when reclosing preparation conditions are met

● The Discrimination Time function is the time to check if the circuit breaker has actually closed during reclosing. It checks for the set time, and if the circuit breaker is not closed, a Fail Signal is output.

  - If set to 0, this function is not used


External Connection


Dimensions

Detailed specification sheets are shown in the product images.