Recdiver Tank KT-0050
Structure and Features
As the air put out from the compressor makes wavelengths, the receiver tank should be installed at the location of the output of the air compressor so that the necessary air can be supplied in uniform pressure without wave motion.
- Although the capacity of the tank is decided according to the use of the compressor, the following diagram can be applied to the general cases.
- The standard one is manufactured in vertical type however, horizontal types can be manufactured according to the order.
- As tanks are applied to the laws of industrial Safety and health, the tanks inspected according to the related authorities should be used.
(All the tank models of the company are the ones inspected by thd authorities of Korea Industrial Safety Corporation)
Specification
| Model | Capacity(N3) | A(I · D) | B | C | D | E | F(PCD) | G | H(IN-OUT) | I | |||||||||||||
| KT-0050 | 0.5㎥ | 750 | 880 | 150 | 150 | 370 | 720 | 1444 | 1 1/2" Screw | φ120 | |||||||||||||
| KT-0060 | 0.6㎥ | 750 | 1106 | 150 | 150 | 370 | 720 | 1670 | 1 1/2" Screw | φ120 | |||||||||||||
| KT-0080 | 0.8㎥ | 750 | 1524 | 150 | 150 | 383 | 720 | 2114 | 1 1/2" Screw | φ120 | |||||||||||||
| KT-0100 | 1.0㎥ | 960 | 1054 | 150 | 150 | 427 | 880 | 1733 | 2" Screw | φ120 | |||||||||||||
| KT-0150 | 1.5㎥ | 960 | 1746 | 150 | 150 | 427 | 880 | 2425 | 2", 2 1/2" Screw | φ120 | |||||||||||||
| KT-0200 | 2.0㎥ | 1200 | 1358 | 200 | 200 | 536 | 1130 | 2208 | 3", 4" FLG | 300×400 | |||||||||||||
| KT-0250 | 2.5㎥ | 1300 | 1438 | 200 | 200 | 586 | 1220 | 2362 | 3", 4" FLG | 300×400 | |||||||||||||
| KT-0300 | 3.0㎥ | 1430 | 1390 | 200 | 200 | 586 | 1384 | 2342 | 3", 4" FLG | 300×400 | |||||||||||||
| KT-0400 | 4.0㎥ | 1500 | 1761 | 250 | 250 | 636 | 1390 | 2782 | 4", 5",6" FLG | 300×400 | |||||||||||||
| KT-0500 | 5.0㎥ | 1500 | 2328 | 250 | 250 | 636 | 1400 | 3349 | 4", 5",6" FLG | 300×400 | |||||||||||||
| KT-0600 | 6.0㎥ | 1630 | 2236 | 250 | 250 | 712 | 1500 | 3412 | 4", 5",6" FLG | 300×400 | |||||||||||||
| KT-0700 | 7.0㎥ | 1720 | 2342 | 300 | 300 | 742 | 1618 | 3570 | 5", 6",8" FLG | 300×400 | |||||||||||||
| KT-0800 | 8.0㎥ | 1820 | 2365 | 300 | 300 | 783 | 1620 | 3663 | 5", 6",8" FLG | 300×400 | |||||||||||||
| KT-0900 | 9.0㎥ | 1920 | 2364 | 300 | 350 | 875 | 1753 | 3779 | 5", 6",8" FLG | 300×400 | |||||||||||||
| KT-1000 | 10㎥ | 1925 | 2690 | 350 | 350 | 845 | 1735 | 4076 | 6", 8",10" FLG | 300×400 | |||||||||||||
| KT-1200 | 12㎥ | 1925 | 3377 | 350 | 350 | 845 | 1765 | 3377 | 6", 8",10" FLG | 300×400 | |||||||||||||
| KT-1500 | 15㎥ | 1925 | 4408 | 420 | 450 | 845 | 1735 | 5794 | 8", 10",12" FLG | 300×400 | |||||||||||||
| KT-2000 | 20㎥ | 2365 | 3656 | 450 | 450 | 945 | 2205 | 3746 | 8", 10",12" FLG | 300×400 | |||||||||||||
| KT-3000 | 30㎥ | 2550 | 4915 | 450 | 420 | 1045 | 2230 | 6659 | 10",12" FLG | 300×400 | |||||||||||||
NOTE.
1) The above specifications are our company's standards and the design pressure is 10kgf/cm2.
2) Other models besides the above specification can be manufactured after consulting with the staff of the company.
3) All the products are the ones inspected by KISCO.
4) ASME DESIGN AND STAMP (Option)
Recdiver Tank KT-0050
Recdiver Tank KT-0050: overview and buying guide
The Recdiver Tank KT-0050 (model KT-0050) is made by KEUMSUNG HIGH TECH and listed in our hydraulic · fluid range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Recdiver Tank KT-0050 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Recdiver Tank KT-0050 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine KEUMSUNG HIGH TECH product?
We purchase directly from KEUMSUNG HIGH TECH or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Structure and Features
As the air put out from the compressor makes wavelengths, the receiver tank should be installed at the location of the output of the air compressor so that the necessary air can be supplied in uniform pressure without wave motion.
- Although the capacity of the tank is decided according to the use of the compressor, the following diagram can be applied to the general cases.
- The standard one is manufactured in vertical type however, horizontal types can be manufactured according to the order.
- As tanks are applied to the laws of industrial Safety and health, the tanks inspected according to the related authorities should be used.
(All the tank models of the company are the ones inspected by thd authorities of Korea Industrial Safety Corporation)
Specification
| Model | Capacity(N3) | A(I · D) | B | C | D | E | F(PCD) | G | H(IN-OUT) | I | |||||||||||||
| KT-0050 | 0.5㎥ | 750 | 880 | 150 | 150 | 370 | 720 | 1444 | 1 1/2" Screw | φ120 | |||||||||||||
| KT-0060 | 0.6㎥ | 750 | 1106 | 150 | 150 | 370 | 720 | 1670 | 1 1/2" Screw | φ120 | |||||||||||||
| KT-0080 | 0.8㎥ | 750 | 1524 | 150 | 150 | 383 | 720 | 2114 | 1 1/2" Screw | φ120 | |||||||||||||
| KT-0100 | 1.0㎥ | 960 | 1054 | 150 | 150 | 427 | 880 | 1733 | 2" Screw | φ120 | |||||||||||||
| KT-0150 | 1.5㎥ | 960 | 1746 | 150 | 150 | 427 | 880 | 2425 | 2", 2 1/2" Screw | φ120 | |||||||||||||
| KT-0200 | 2.0㎥ | 1200 | 1358 | 200 | 200 | 536 | 1130 | 2208 | 3", 4" FLG | 300×400 | |||||||||||||
| KT-0250 | 2.5㎥ | 1300 | 1438 | 200 | 200 | 586 | 1220 | 2362 | 3", 4" FLG | 300×400 | |||||||||||||
| KT-0300 | 3.0㎥ | 1430 | 1390 | 200 | 200 | 586 | 1384 | 2342 | 3", 4" FLG | 300×400 | |||||||||||||
| KT-0400 | 4.0㎥ | 1500 | 1761 | 250 | 250 | 636 | 1390 | 2782 | 4", 5",6" FLG | 300×400 | |||||||||||||
| KT-0500 | 5.0㎥ | 1500 | 2328 | 250 | 250 | 636 | 1400 | 3349 | 4", 5",6" FLG | 300×400 | |||||||||||||
| KT-0600 | 6.0㎥ | 1630 | 2236 | 250 | 250 | 712 | 1500 | 3412 | 4", 5",6" FLG | 300×400 | |||||||||||||
| KT-0700 | 7.0㎥ | 1720 | 2342 | 300 | 300 | 742 | 1618 | 3570 | 5", 6",8" FLG | 300×400 | |||||||||||||
| KT-0800 | 8.0㎥ | 1820 | 2365 | 300 | 300 | 783 | 1620 | 3663 | 5", 6",8" FLG | 300×400 | |||||||||||||
| KT-0900 | 9.0㎥ | 1920 | 2364 | 300 | 350 | 875 | 1753 | 3779 | 5", 6",8" FLG | 300×400 | |||||||||||||
| KT-1000 | 10㎥ | 1925 | 2690 | 350 | 350 | 845 | 1735 | 4076 | 6", 8",10" FLG | 300×400 | |||||||||||||
| KT-1200 | 12㎥ | 1925 | 3377 | 350 | 350 | 845 | 1765 | 3377 | 6", 8",10" FLG | 300×400 | |||||||||||||
| KT-1500 | 15㎥ | 1925 | 4408 | 420 | 450 | 845 | 1735 | 5794 | 8", 10",12" FLG | 300×400 | |||||||||||||
| KT-2000 | 20㎥ | 2365 | 3656 | 450 | 450 | 945 | 2205 | 3746 | 8", 10",12" FLG | 300×400 | |||||||||||||
| KT-3000 | 30㎥ | 2550 | 4915 | 450 | 420 | 1045 | 2230 | 6659 | 10",12" FLG | 300×400 | |||||||||||||
NOTE.
1) The above specifications are our company's standards and the design pressure is 10kgf/cm2.
2) Other models besides the above specification can be manufactured after consulting with the staff of the company.
3) All the products are the ones inspected by KISCO.
4) ASME DESIGN AND STAMP (Option)