{"product_id":"protection-132999","title":"Protection GIPAM3000","description":"\u003cp\u003e\u003cstrong\u003eGIPAM3000\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMultifunctional digital power protection monitoring device with various protection elements and measurement elements\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eProtection function\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eㆍWith 34 types of protection elements in 2 models, the distribution system fully protected\u003c\/p\u003e \u003cp\u003eㆍEnhanced analysis function through various saved event data (up to 1,000 events are saved)\u003c\/p\u003e \u003cp\u003eㆍTrip logic and sequence with Programmable Logic Controller and 1,024 in\/output port\u003c\/p\u003e \u003cp\u003eㆍExtended power quality monitoring\u003c\/p\u003e \u003cp\u003eㆍSelect Before Operating (SBO) and Check Before Operating (CBO)\u003c\/p\u003e \u003cp\u003eㆍVector diagram\u003c\/p\u003e \u003cp\u003eㆍTrip Circuit Supervision (TCS) and Trip Relay Supervision (TRS)\u003c\/p\u003e \u003cp\u003eㆍSequence of Event (SOE)\u003c\/p\u003e \u003cp\u003eㆍPT (VT) failure detection\u003c\/p\u003e \u003cp\u003eㆍCircuit Breaker Failure (CBF)\u003c\/p\u003e \u003cp\u003eㆍCold Load Pickup (CLP)\u003c\/p\u003e \u003cp\u003eㆍRoot Mean Square (RMS) trend\u003c\/p\u003e \u003cp\u003eㆍDisk emulation\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eConvenience function\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eㆍSelf-diagnosis and sequence monitoring\u003c\/p\u003e \u003cp\u003eㆍHMI with enhanced visibility and convenience\u003c\/p\u003e \u003cp\u003eㆍConvenient lever withdrawal structure\u003c\/p\u003e \u003cp\u003eㆍLong-life and reliable parts applied\u003c\/p\u003e \u003cp\u003eㆍFully compatible with previous models (GIPAM2000\/2200)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eCommunication function\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eㆍVarious communication compatibility (MODBUS, DNP, IEC61850)\u003c\/p\u003e \u003cp\u003eㆍRemote access using PC Manager\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eProtection factor\u003c\/strong\u003e\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eType\u003c\/th\u003e \u003cth\u003eUsage\u003c\/th\u003e \u003cth colspan=\"3\"\u003eProtection\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eGIPAM3000 FI\u003c\/th\u003e \u003ctd\u003eFeeder\/Incoming\u003cbr\u003e\u003cbr\u003eMotor\u003cbr\u003e\u003cbr\u003eDistributed Generator\u003c\/td\u003e \u003ctd\u003eOCR (50\/51)\u003cbr\u003eSEL (51S) Note1)\u003cbr\u003eUVRR (27R)\u003cbr\u003eOVGR (64) Note3)\u003cbr\u003eDPR (32P)\u003cbr\u003eUFR (81U)\u003cbr\u003eNSOCR (46)\u003cbr\u003eUPR (37)\u003cbr\u003eRECLOSING (79)\u003cbr\u003ePTF (60F)\u003c\/td\u003e \u003ctd\u003eOCGR (50\/51N)\u003cbr\u003eDOCGR (67NI\/67ND)Note1)\u003cbr\u003eOVR (59)\u003cbr\u003eNSOVR (47N)\u003cbr\u003eDQR (32Q)\u003cbr\u003eOFR (81O)\u003cbr\u003eTHR (49)\u003cbr\u003eUVR (37)\u003cbr\u003eNCH (66)\u003cbr\u003eCLP\u003c\/td\u003e \u003ctd\u003eSGR (67G)\u003cbr\u003eUVR (27)\u003cbr\u003eOVRR (59R)\u003cbr\u003ePOR (47P)\u003cbr\u003eDOCR (67I\/67D)\u003cbr\u003eROCOF (81R)\u003cbr\u003eSTALL\/LOCK (48\/51LR)\u003cbr\u003eSYNC (25)\u003cbr\u003eCBF (50BF)\u003cbr\u003eLOCK-OUT (86)Note4)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eGIPAM3000 T\u003c\/th\u003e \u003ctd\u003eTransformer\u003c\/td\u003e \u003ctd\u003eOCR (50\/51w1)\u003cbr\u003eOCGR (50\/51N-1)\u003cbr\u003eDFRG (87N)\u003c\/td\u003e \u003ctd\u003eOCR (50\/51w2)\u003cbr\u003eOCGR (50\/51N-2)\u003cbr\u003eLOCK-OUT (86)Note4)\u003c\/td\u003e \u003ctd\u003eOCR (50\/51w3)\u003cbr\u003eDFR (87T)Note5)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003eNote) 1. Sensitive Earth Fault (SEF) is a relay element that detects the earth current in the event of an earth accident in the non-ground\u003c\/p\u003e \u003cp\u003e           2. DOCGR is the same as DGR.\u003c\/p\u003e \u003cp\u003e           3. OVGR is ALRAM with no breaker TRIP In factory-shipped products\u003c\/p\u003e \u003cp\u003e           4. Lock-out (86) can be configured with PLC Trip Logic\u003c\/p\u003e \u003cp\u003e           5. The Inrush Detector (68) element is included in the DFR (87T) elemen\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eType\u003c\/th\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eWiring\u003c\/th\u003e \u003ctd\u003e3P3W (2PT-D), 3P4W (3PT-Y)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"8\"\u003eRating\u003c\/th\u003e \u003cth colspan=\"2\"\u003eFrequancy\u003c\/th\u003e \u003ctd\u003e60Hz, 50Hz Note)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eVoltage\u003c\/th\u003e \u003cth\u003ePT\u003c\/th\u003e \u003ctd\u003e110V (55~125V)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eGPT\u003c\/th\u003e \u003ctd\u003eVn*√3 Vn: PT secondary rating voltage\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eCurrent\u003c\/th\u003e \u003cth\u003eCT\u003c\/th\u003e \u003ctd\u003e5A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eZCT\u003c\/th\u003e \u003ctd\u003e1.5mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003ePower\u003c\/th\u003e \u003ctd\u003eAC\/DC110V, DC125V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003ePower consumption\u003c\/th\u003e \u003ctd\u003e30W or less: Stanby \/ 50W or less: Operation\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003eBurden\u003c\/th\u003e \u003ctd\u003e0.5VA or less: PT\u003cbr\u003e1.0VA or less: CT\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003eInput contact\u003c\/th\u003e \u003cth\u003efor general\u003c\/th\u003e \u003ctd\u003eDigital Input AC\/DC 110V, DC125V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\" rowspan=\"2\"\u003eOutput contact\u003c\/th\u003e \u003cth\u003efor trip\u003c\/th\u003e \u003ctd\u003eAC 250V 16A\/DC 30V 16A, Resistive Load: Rated Capacity\u003cbr\u003eAC 4000VA, DC 480W: Opening Capacity\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003efor alarm\u003c\/th\u003e \u003ctd\u003eAC 250V 5A\/DC 30V 5A, Resistive Load: Closed Capacity\u003cbr\u003eAC 1250VA, DC 150W: Opening Capacity\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\" rowspan=\"2\"\u003eTolerance\u003c\/th\u003e \u003cth\u003eOperation Value\u003c\/th\u003e \u003ctd\u003e±5%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOperation Time\u003c\/th\u003e \u003ctd\u003e±5% or ±35ms\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eOInsulation Resistance\u003c\/th\u003e \u003ctd\u003eDC 500V 100MΩ or more\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eInsulation Voltage\u003c\/th\u003e \u003ctd\u003eAC 2kV (1kV)\/1min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eLightning impulse voltage\u003c\/th\u003e \u003ctd\u003eAC 5kV (3kV) or more, 1.2x50μs standard waveform supplied\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\" rowspan=\"2\"\u003eOverload withstand\u003c\/th\u003e \u003cth\u003eCurrent circuit\u003c\/th\u003e \u003ctd\u003eWithstand 1.2 times of rated current continuously\u003cbr\u003eWithstand 2 times of rated current for 3 hours.\u003cbr\u003eWithstand 20 times of rated current for 2 seconds.\u003cbr\u003eWithstand 40 times of rated current for 1 second.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eVoltage circuit\u003c\/th\u003e \u003ctd\u003eWithstand 1.15 times of rated voltage for 3 hours.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eFast Transient Disturbance\u003c\/th\u003e \u003ctd\u003e4kV: power input\u003cbr\u003e2kV: other input\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eElectrostatic Discharge (ESD)\u003c\/th\u003e \u003ctd\u003e8kV: Air, 6kV: Contact\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\" rowspan=\"2\"\u003eTemperature\u003c\/th\u003e \u003cth\u003eOperation\u003c\/th\u003e \u003ctd\u003e-25℃ ~ 60℃\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eStorage\u003c\/th\u003e \u003ctd\u003e-40℃ ~ 70℃\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eHumidity\u003c\/th\u003e \u003ctd\u003eRH 80% or less (non-condensing)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eAltitude\u003c\/th\u003e \u003ctd\u003e2,000m or less\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eEnvironment\u003c\/th\u003e \u003ctd\u003eA place not subject to abnormal vibration and shock.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eApplied Standards\u003c\/th\u003e \u003ctd\u003eKEMC 1120\u003cbr\u003eIEC 61000-4-2 ~ 4-6, 4-8, 4-11, 4-16, 4-17, 4-18, 4-29\u003cbr\u003eCISPR 11, 22\u003cbr\u003eIEC 60255-26\u003cbr\u003eIEC 61850-6, 7-1, 7-2, 7-3, 7-4, and 8-1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eDimension (mm)\u003c\/th\u003e \u003ctd\u003e209 (W)x185.8 (D)x260 (H): Cutting Size\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eWeignt\u003c\/th\u003e \u003ctd\u003e10.3kg\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eCommunication\u003c\/th\u003e \u003ctd\u003eRS485: Modbus, DNP3.0\u003cbr\u003eEthernet TE: Modbus, DNP3.0, IEC61850\u003cbr\u003eEthernet FE: Modbus, DNP3.0, IEC61850\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-bf3cc08f2149077b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-LS ELECTRIC-Protection-GIPAM3000\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-10047454ab1f4db4.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRemote Communication Manual-LS ELECTRIC-Protection-GIPAM3000\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-8d9343e43aa694ca.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePLC Logic edit Manual-LS ELECTRIC-Protection-GIPAM3000\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LS ELECTRIC","offers":[{"title":"Default Title","offer_id":58446597325140,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/b0aef529-69ac-4ee8-89fe-cde7ad5f2559.jpg?v=1795191292","url":"https:\/\/premiumemart.com\/products\/protection-132999","provider":"Premium Emart","version":"1.0","type":"link"}