{"product_id":"protection-132998","title":"Protection XGIPAM","description":"\u003cp\u003e\u003cstrong\u003eXGIPAM\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eNext generation digital power protection monitoring system for highly reliable plant facilities.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eProtection Function\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eㆍVarious protection factors (29 protection factors)\u003c\/p\u003e \u003cp\u003eㆍEvent and fault recording (max 1,000 recording)\u003c\/p\u003e \u003cp\u003eㆍVarious measurements and monitoring functions (25 measurements)\u003c\/p\u003e \u003cp\u003eㆍTrip logic and PLC function\u003c\/p\u003e \u003cp\u003eㆍMimic diagram function\u003c\/p\u003e \u003cp\u003eㆍAdvanced power quality measurements (2~63rd harmonic)\u003c\/p\u003e \u003cp\u003eㆍSelect \u0026amp; check before operating (CBO) functions\u003c\/p\u003e \u003cp\u003eㆍVector diagram\u003c\/p\u003e \u003cp\u003eㆍTime characteristic curve\u003c\/p\u003e \u003cp\u003eㆍTrip circuit supervision (TCS) \u0026amp; trip relay supervision (TRS)\u003c\/p\u003e \u003cp\u003eㆍSequence of events (SOE)\u003c\/p\u003e \u003cp\u003eㆍHarmonic spectrum\u003c\/p\u003e \u003cp\u003eㆍAnalog input (optional)\u003c\/p\u003e \u003cp\u003eㆍInput\/output points monitoring and control function\u003c\/p\u003e \u003cp\u003eㆍSupervision of CB capacity limit\u003c\/p\u003e \u003cp\u003eㆍBay controller function\u003c\/p\u003e \u003cp\u003eㆍArc protection module (optional)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eConvenience Function\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eㆍEasy connecting to PC manager\u003c\/p\u003e \u003cp\u003eㆍEasy setting group\u003c\/p\u003e \u003cp\u003eㆍFlexible modular architecture hardware and software\u003c\/p\u003e \u003cp\u003eㆍ8.4″ inches of large color touch screen\u003c\/p\u003e \u003cp\u003eㆍLanguage selection and user selective menu (eng\/kor)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eCommunication Function\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eㆍVarious communication compatibilities\u003c\/p\u003e \u003cp\u003eㆍCommunication redundancy\u003c\/p\u003e \u003cp\u003eㆍIEC61850 communication\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eProtection factor\u003c\/strong\u003e\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eType\u003c\/th\u003e \u003cth\u003eUsage\u003c\/th\u003e \u003cth\u003eProtection\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eXGIPAM-F\u003c\/th\u003e \u003cth\u003eFeeder\/Incomming\u003c\/th\u003e \u003ctd\u003eOCR(50\/51), OCGR(50\/51N), UVR(27), OVR(59), SGR(67G), DGR(67N), OVGR(64I\/D), NSOVR(47N), POR(47), SYNC Check(25),\u003cbr\u003eReclosing(79), Temperature(38)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eXGIPAM-B\u003c\/th\u003e \u003cth\u003eBay Controller\u003c\/th\u003e \u003ctd\u003eOCR(50\/51), OCGR(50\/51N), UVR(27), OVR(59), SGR(67G), DGR(67N), OVGR(64I\/D), NSOVR(47N), POR(47), \u003cbr\u003eSYNC Check(25), Reclosing(79), Temperature(38), DOCR(67I\/D), NSOCR(46I\/D), UFR(81U), OFR(81O), DPR(32P), DQR(32Q)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eXGIPAM-M\u003c\/th\u003e \u003cth\u003eMotor\u003c\/th\u003e \u003ctd\u003eOCR(50\/51), OCGR(50\/51N), UVR(27), OVR(59), SGR(67G), DGR(67N), OVGR(64I\/D), NSOVR(47N), POR(47), Temperature(38), \u003cbr\u003eStall\/Locked Rotor(48\/51LR), THR(49), DOCR(67I\/D), UCR(37), NCH(66), NSOCR(46I\/D)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eXGIPAM-T\u003c\/th\u003e \u003cth\u003eTransformer\u003c\/th\u003e \u003ctd\u003eOCR(50\/51)*2,OCGR(50\/51N),UVR(27),OVR(59),Temperature(38),DPR(32P),DFR(87T)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eXGIPAM-DG\u003c\/th\u003e \u003cth\u003eDistributed\u003cbr\u003eGenerator\u003c\/th\u003e \u003ctd\u003eOCR(50\/51), OCGR(50\/51N), UVR(27), OVR(59), DPR(32P), UPR(37P), DQR(32Q), UFR(81U), OFR(81O), DGR(67N), \u003cbr\u003eSYNC Check(25), DOCR(67I\/D), NSOCR(46I\/D), POR(47), NSOVR(47N), ROCOF(81R), SGR(67G), OVGR(64I\/D)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eXGIPAM-3wT\u003c\/th\u003e \u003cth\u003eTransformer\u003cbr\u003e(3 wires)\u003c\/th\u003e \u003ctd\u003eOCR(50\/51)×3, OCGR(50N\/51N), UVR(27), OVR(59), OVGR(64I\/D), DFR(3W87T)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eRating\u003c\/th\u003e \u003cth colspan=\"2\"\u003eSpecification\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eWiring\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  3P3W, 3P4W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"6\"\u003eInput\u003c\/th\u003e \u003cth colspan=\"2\"\u003eFrequency\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  60Hz\/50Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003eVoltage\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  PT: 100\/ √3, 110\/ √3, 120\/ √3, 190\/ √3, 100, 110, 120V\u003cbr\u003e  GPT: 100~190V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003eCurrent\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  CT: 5A, ZCT: 1.5mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003ePower consumption\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  Standby: Max. 30W, Operating: Max. 70W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003eControl voltage\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  AC110V\/DC110~125V, 50\/60Hz \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003eBurden\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  PT: Max. 0.5VA(Phase PT Standard), CT: Max. 1.0VA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"4\"\u003eOutput contact\u003c\/th\u003e \u003cth rowspan=\"2\"\u003eTRIP\u003c\/th\u003e \u003cth\u003eRated\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  AC 250V 10A \/ DC 30V 10A, Resistive Load\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOpen\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  AC 2500VA, DC 300W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eALARM\u003c\/th\u003e \u003cth\u003eRated\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  AC 250V 5A \/ DC 30V 5A, Resistive Load\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOpen\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  AC 1250VA, DC 150W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eInsulation Resistance\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  Over DC 500V 10㏁\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eDielectric strength\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  AC 2kV(1kV) \/ for 1 min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth rowspan=\"2\"\u003eOverload withstand\u003c\/th\u003e \u003cth colspan=\"2\"\u003eCurrent circuit\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  Twice the rated current is no problem after 3hours of application.\u003cbr\u003e  20 times of the rated current is no problem when applied for 2seconds.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003eVoltage circuit\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  1.15times of rated voltage is no problem after 3hours of application\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eFast Transient Disturbance\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  Power Input 4kV, DI\/DO input 2kV, Other Input 1kV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eElectrostatic Discharge(ESD)\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  Air 8kV, Contact 6kV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eOperation temperature\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  -10℃ ~ 55℃\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eStorage temperature\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  -25℃ ~ 70℃\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eHumidity\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  Within 80% RH, no condensation\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eAltitude\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e 1500m or less\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eOthers\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e No vibration and shock, no air pollution\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eStandard\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  IEC 60255-22-1: 1MHz Burst disturbance tests\u003cbr\u003e  IEC 60255-22-2: Electrostatic discharge tests\u003cbr\u003e  IEC 60255-22-3: Radiated radio frequency electromagnetic field\u003cbr\u003e  IEC 60255-22-4: Electrical fast transient\/burst immunity test\u003cbr\u003e  IEC 60255-22-5: Surge immunity test\u003cbr\u003e  IEC 60255-22-6: Immunity to conducted disturbances induced by radio frequency fields\u003cbr\u003e  IEC 60255-22-7: Power frequency immunity test\u003cbr\u003e  IEC 60255-11: Interruptions to and alternating component (ripple) in d.c. auxiliary quantity of measuring relay\u003cbr\u003e  IEC 60255-25: Electromagnetic emission tests for measuring relays and protection equipment\u003cbr\u003e  KEMC 1120\u003cbr\u003e  IEC 6850-6,7-1,7-2,7-3, and 8-1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eWeight\u003c\/th\u003e \u003ctd colspan=\"2\"\u003e  7 kg (HMI: 2kg)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-f550384a2d56d82b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-LS ELECTRIC-Protection-XGIPAM UL type\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-9cd211665800032e.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-LS ELECTRIC-Protection-XGIPAM\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LS ELECTRIC","offers":[{"title":"Default Title","offer_id":58446596931924,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/48c1e7cf-e52d-478e-9ecf-00bc8b92c9de.jpg?v=1795191291","url":"https:\/\/premiumemart.com\/products\/protection-132998","provider":"Premium Emart","version":"1.0","type":"link"}