Protection XGIPAM
XGIPAM
Next generation digital power protection monitoring system for highly reliable plant facilities.
Features
Protection Function
ㆍVarious protection factors (29 protection factors)
ㆍEvent and fault recording (max 1,000 recording)
ㆍVarious measurements and monitoring functions (25 measurements)
ㆍTrip logic and PLC function
ㆍMimic diagram function
ㆍAdvanced power quality measurements (2~63rd harmonic)
ㆍSelect & check before operating (CBO) functions
ㆍVector diagram
ㆍTime characteristic curve
ㆍTrip circuit supervision (TCS) & trip relay supervision (TRS)
ㆍSequence of events (SOE)
ㆍHarmonic spectrum
ㆍAnalog input (optional)
ㆍInput/output points monitoring and control function
ㆍSupervision of CB capacity limit
ㆍBay controller function
ㆍArc protection module (optional)
Convenience Function
ㆍEasy connecting to PC manager
ㆍEasy setting group
ㆍFlexible modular architecture hardware and software
ㆍ8.4″ inches of large color touch screen
ㆍLanguage selection and user selective menu (eng/kor)
Communication Function
ㆍVarious communication compatibilities
ㆍCommunication redundancy
ㆍIEC61850 communication
Protection factor
| Type | Usage | Protection |
|---|---|---|
| XGIPAM-F | Feeder/Incomming | OCR(50/51), OCGR(50/51N), UVR(27), OVR(59), SGR(67G), DGR(67N), OVGR(64I/D), NSOVR(47N), POR(47), SYNC Check(25), Reclosing(79), Temperature(38) |
| XGIPAM-B | Bay Controller | OCR(50/51), OCGR(50/51N), UVR(27), OVR(59), SGR(67G), DGR(67N), OVGR(64I/D), NSOVR(47N), POR(47), SYNC Check(25), Reclosing(79), Temperature(38), DOCR(67I/D), NSOCR(46I/D), UFR(81U), OFR(81O), DPR(32P), DQR(32Q) |
| XGIPAM-M | Motor | OCR(50/51), OCGR(50/51N), UVR(27), OVR(59), SGR(67G), DGR(67N), OVGR(64I/D), NSOVR(47N), POR(47), Temperature(38), Stall/Locked Rotor(48/51LR), THR(49), DOCR(67I/D), UCR(37), NCH(66), NSOCR(46I/D) |
| XGIPAM-T | Transformer | OCR(50/51)*2,OCGR(50/51N),UVR(27),OVR(59),Temperature(38),DPR(32P),DFR(87T) |
| XGIPAM-DG | Distributed Generator | OCR(50/51), OCGR(50/51N), UVR(27), OVR(59), DPR(32P), UPR(37P), DQR(32Q), UFR(81U), OFR(81O), DGR(67N), SYNC Check(25), DOCR(67I/D), NSOCR(46I/D), POR(47), NSOVR(47N), ROCOF(81R), SGR(67G), OVGR(64I/D) |
| XGIPAM-3wT | Transformer (3 wires) | OCR(50/51)×3, OCGR(50N/51N), UVR(27), OVR(59), OVGR(64I/D), DFR(3W87T) |
Specification
| Rating | Specification | |||
|---|---|---|---|---|
| Wiring | 3P3W, 3P4W | |||
| Input | Frequency | 60Hz/50Hz | ||
| Voltage | PT: 100/ √3, 110/ √3, 120/ √3, 190/ √3, 100, 110, 120V GPT: 100~190V | |||
| Current | CT: 5A, ZCT: 1.5mA | |||
| Power consumption | Standby: Max. 30W, Operating: Max. 70W | |||
| Control voltage | AC110V/DC110~125V, 50/60Hz | |||
| Burden | PT: Max. 0.5VA(Phase PT Standard), CT: Max. 1.0VA | |||
| Output contact | TRIP | Rated | AC 250V 10A / DC 30V 10A, Resistive Load | |
| Open | AC 2500VA, DC 300W | |||
| ALARM | Rated | AC 250V 5A / DC 30V 5A, Resistive Load | ||
| Open | AC 1250VA, DC 150W | |||
| Insulation Resistance | Over DC 500V 10㏁ | |||
| Dielectric strength | AC 2kV(1kV) / for 1 min | |||
| Overload withstand | Current circuit | Twice the rated current is no problem after 3hours of application. 20 times of the rated current is no problem when applied for 2seconds. | ||
| Voltage circuit | 1.15times of rated voltage is no problem after 3hours of application | |||
| Fast Transient Disturbance | Power Input 4kV, DI/DO input 2kV, Other Input 1kV | |||
| Electrostatic Discharge(ESD) | Air 8kV, Contact 6kV | |||
| Operation temperature | -10℃ ~ 55℃ | |||
| Storage temperature | -25℃ ~ 70℃ | |||
| Humidity | Within 80% RH, no condensation | |||
| Altitude | 1500m or less | |||
| Others | No vibration and shock, no air pollution | |||
| Standard | IEC 60255-22-1: 1MHz Burst disturbance tests IEC 60255-22-2: Electrostatic discharge tests IEC 60255-22-3: Radiated radio frequency electromagnetic field IEC 60255-22-4: Electrical fast transient/burst immunity test IEC 60255-22-5: Surge immunity test IEC 60255-22-6: Immunity to conducted disturbances induced by radio frequency fields IEC 60255-22-7: Power frequency immunity test IEC 60255-11: Interruptions to and alternating component (ripple) in d.c. auxiliary quantity of measuring relay IEC 60255-25: Electromagnetic emission tests for measuring relays and protection equipment KEMC 1120 IEC 6850-6,7-1,7-2,7-3, and 8-1 | |||
| Weight | 7 kg (HMI: 2kg) | |||
Catalogues
Protection XGIPAM
Protection XGIPAM: overview and buying guide
The Protection XGIPAM (model XGIPAM) is made by LS ELECTRIC and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Protection XGIPAM cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Protection XGIPAM to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine LS ELECTRIC product?
We purchase directly from LS ELECTRIC or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
XGIPAM
Next generation digital power protection monitoring system for highly reliable plant facilities.
Features
Protection Function
ㆍVarious protection factors (29 protection factors)
ㆍEvent and fault recording (max 1,000 recording)
ㆍVarious measurements and monitoring functions (25 measurements)
ㆍTrip logic and PLC function
ㆍMimic diagram function
ㆍAdvanced power quality measurements (2~63rd harmonic)
ㆍSelect & check before operating (CBO) functions
ㆍVector diagram
ㆍTime characteristic curve
ㆍTrip circuit supervision (TCS) & trip relay supervision (TRS)
ㆍSequence of events (SOE)
ㆍHarmonic spectrum
ㆍAnalog input (optional)
ㆍInput/output points monitoring and control function
ㆍSupervision of CB capacity limit
ㆍBay controller function
ㆍArc protection module (optional)
Convenience Function
ㆍEasy connecting to PC manager
ㆍEasy setting group
ㆍFlexible modular architecture hardware and software
ㆍ8.4″ inches of large color touch screen
ㆍLanguage selection and user selective menu (eng/kor)
Communication Function
ㆍVarious communication compatibilities
ㆍCommunication redundancy
ㆍIEC61850 communication
Protection factor
| Type | Usage | Protection |
|---|---|---|
| XGIPAM-F | Feeder/Incomming | OCR(50/51), OCGR(50/51N), UVR(27), OVR(59), SGR(67G), DGR(67N), OVGR(64I/D), NSOVR(47N), POR(47), SYNC Check(25), Reclosing(79), Temperature(38) |
| XGIPAM-B | Bay Controller | OCR(50/51), OCGR(50/51N), UVR(27), OVR(59), SGR(67G), DGR(67N), OVGR(64I/D), NSOVR(47N), POR(47), SYNC Check(25), Reclosing(79), Temperature(38), DOCR(67I/D), NSOCR(46I/D), UFR(81U), OFR(81O), DPR(32P), DQR(32Q) |
| XGIPAM-M | Motor | OCR(50/51), OCGR(50/51N), UVR(27), OVR(59), SGR(67G), DGR(67N), OVGR(64I/D), NSOVR(47N), POR(47), Temperature(38), Stall/Locked Rotor(48/51LR), THR(49), DOCR(67I/D), UCR(37), NCH(66), NSOCR(46I/D) |
| XGIPAM-T | Transformer | OCR(50/51)*2,OCGR(50/51N),UVR(27),OVR(59),Temperature(38),DPR(32P),DFR(87T) |
| XGIPAM-DG | Distributed Generator | OCR(50/51), OCGR(50/51N), UVR(27), OVR(59), DPR(32P), UPR(37P), DQR(32Q), UFR(81U), OFR(81O), DGR(67N), SYNC Check(25), DOCR(67I/D), NSOCR(46I/D), POR(47), NSOVR(47N), ROCOF(81R), SGR(67G), OVGR(64I/D) |
| XGIPAM-3wT | Transformer (3 wires) | OCR(50/51)×3, OCGR(50N/51N), UVR(27), OVR(59), OVGR(64I/D), DFR(3W87T) |
Specification
| Rating | Specification | |||
|---|---|---|---|---|
| Wiring | 3P3W, 3P4W | |||
| Input | Frequency | 60Hz/50Hz | ||
| Voltage | PT: 100/ √3, 110/ √3, 120/ √3, 190/ √3, 100, 110, 120V GPT: 100~190V | |||
| Current | CT: 5A, ZCT: 1.5mA | |||
| Power consumption | Standby: Max. 30W, Operating: Max. 70W | |||
| Control voltage | AC110V/DC110~125V, 50/60Hz | |||
| Burden | PT: Max. 0.5VA(Phase PT Standard), CT: Max. 1.0VA | |||
| Output contact | TRIP | Rated | AC 250V 10A / DC 30V 10A, Resistive Load | |
| Open | AC 2500VA, DC 300W | |||
| ALARM | Rated | AC 250V 5A / DC 30V 5A, Resistive Load | ||
| Open | AC 1250VA, DC 150W | |||
| Insulation Resistance | Over DC 500V 10㏁ | |||
| Dielectric strength | AC 2kV(1kV) / for 1 min | |||
| Overload withstand | Current circuit | Twice the rated current is no problem after 3hours of application. 20 times of the rated current is no problem when applied for 2seconds. | ||
| Voltage circuit | 1.15times of rated voltage is no problem after 3hours of application | |||
| Fast Transient Disturbance | Power Input 4kV, DI/DO input 2kV, Other Input 1kV | |||
| Electrostatic Discharge(ESD) | Air 8kV, Contact 6kV | |||
| Operation temperature | -10℃ ~ 55℃ | |||
| Storage temperature | -25℃ ~ 70℃ | |||
| Humidity | Within 80% RH, no condensation | |||
| Altitude | 1500m or less | |||
| Others | No vibration and shock, no air pollution | |||
| Standard | IEC 60255-22-1: 1MHz Burst disturbance tests IEC 60255-22-2: Electrostatic discharge tests IEC 60255-22-3: Radiated radio frequency electromagnetic field IEC 60255-22-4: Electrical fast transient/burst immunity test IEC 60255-22-5: Surge immunity test IEC 60255-22-6: Immunity to conducted disturbances induced by radio frequency fields IEC 60255-22-7: Power frequency immunity test IEC 60255-11: Interruptions to and alternating component (ripple) in d.c. auxiliary quantity of measuring relay IEC 60255-25: Electromagnetic emission tests for measuring relays and protection equipment KEMC 1120 IEC 6850-6,7-1,7-2,7-3, and 8-1 | |||
| Weight | 7 kg (HMI: 2kg) | |||