{"product_id":"pld-88717","title":"PLD KVP-2000 Seires","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePLD (Pulsed Laser Deposition) is a physical deposition method that utilizes a high energy\u003c\/p\u003e\u003cp\u003efocused laser. Conceptually and experimentally. PLD is extremely simple. It consists of a\u003c\/p\u003e\u003cp\u003etarget holder and a substrate holder housed in a vacuum chamber. A set of optical\u003c\/p\u003e\u003cp\u003ecomponents focus and raster a high-power laser (the external source) into a\u003c\/p\u003e\u003cp\u003econcentrated beam over the target surface which vaporizes target materials to\u003c\/p\u003e\u003cp\u003eultimately deposite thin film.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e≻ Allows for the use of various targets and for the in-situ deposition of multi-layers\u003c\/p\u003e\u003cp\u003e≻ Consists of simple hardware\u003c\/p\u003e\u003cp\u003e≻ Simple system maintenance\u003c\/p\u003e\u003cp\u003e≻ Various aspect of beam-target-substrate positioning\u003c\/p\u003e\u003cp\u003e≻ Temperature uniformity of substrate\u003c\/p\u003e\u003cp\u003e≻ Pyrometer Port\u003c\/p\u003e\u003cp\u003e≻ Laser strength measurement port\u003c\/p\u003e\u003cp\u003e≻ Ellipsometry port\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUHV chamber Ultimate Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eup to 5.0E-9Torr\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTwo Chamber System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess chamber \u0026amp; Loadlock chamber\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUniformity Zone of Substrate Heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eØ15 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubstrate Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e850°C ± 5°C in oxygen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.01mTor ~ 10 Torr\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTarget Carousel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eone inch (25.4mm) diameter for four targets\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Angle of Incidence\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser beam on target : 45° with respect to target normal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEasy to load or unload sample and target by magnetic transfer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRHEED (Reflection High-Energy Electron Diffraction)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCCD Camera for Oscillation of RHEED\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePyrometer for measuring substrate temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eControl\u003c\/h3\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePLD (Pulsed Laser Deposition) is a physical deposition method that utilizes a high energy\u003c\/p\u003e\u003cp\u003efocused laser. Conceptually and experimentally. PLD is extremely simple. It consists of a\u003c\/p\u003e\u003cp\u003etarget holder and a substrate holder housed in a vacuum chamber. A set of optical\u003c\/p\u003e\u003cp\u003ecomponents focus and raster a high-power laser (the external source) into a\u003c\/p\u003e\u003cp\u003econcentrated beam over the target surface which vaporizes target materials to\u003c\/p\u003e\u003cp\u003eultimately deposite thin film.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e≻ Allows for the use of various targets and for the in-situ deposition of multi-layers\u003c\/p\u003e\u003cp\u003e≻ Consists of simple hardware\u003c\/p\u003e\u003cp\u003e≻ Simple system maintenance\u003c\/p\u003e\u003cp\u003e≻ Various aspect of beam-target-substrate positioning\u003c\/p\u003e\u003cp\u003e≻ Temperature uniformity of substrate\u003c\/p\u003e\u003cp\u003e≻ Pyrometer Port\u003c\/p\u003e\u003cp\u003e≻ Laser strength measurement port\u003c\/p\u003e\u003cp\u003e≻ Ellipsometry port\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUniformity Zone of Substrate Heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eØ15 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubstrate Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e850°C ± 5°C in oxygen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.01 mTorr ~ 10 Torr\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTarget Carousel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eone inch (25.4mm) diameter for four targets\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Angle of Incidence\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser beam on target : 45° with respect to target normal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e248 nm (KrF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.0E-7 Torr using turbo molecular pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eControl\u003c\/h3\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e","brand":"Korea Vacuum Tech","offers":[{"title":"Default Title","offer_id":58448971268436,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/koreavac_co_kr_20180831_162239.png?v=1795195381","url":"https:\/\/premiumemart.com\/products\/pld-88717","provider":"Premium Emart","version":"1.0","type":"link"}