PLC XGR-CPU (XGT Series)
Features
High performance
ㆍProcessing speed: 42ns/step
ㆍCPU synchronization via fiber optic cable
ㆍI/O Points: Max. 131,072
ㆍTotal memory: 25MB (Program 3MB, System 4MB, Data 2MB, Flash 16MB)
ㆍSwitching over time: 22ms
Easy expansion installation using network
ㆍMax.31 expansion base
ㆍDistance: Fiber optic 2km (Max. expansion 60km), Twisted fair 100m (Max. expansion 3km)
ㆍProgram upload and download via expansion base
ㆍNo limit to install the communication master on the expansion base
Enhanced maintenance via system history and network ring configuration
ㆍConvenient system analyze using Operation history, Error history, System History
ㆍRing configuration to prevent a line disconnection error
ㆍNetwork monitoring, Protocol monitoring function
ㆍError channel monitoring via flag
ㆍGraphic display for the system configuration
ㆍSafe module exchange via Wizard
IEC 61131-3 Standard language
ㆍLD, ST, SFC, IL (read only)
ㆍProgram configuration and data type based on IEC
Specifications
| Item | Description | Remark | |||
|---|---|---|---|---|---|
| XGR-CPUH/F | XGR-CPUH/T | ||||
| Media | Fiber optic | Twisted pair | |||
| Operation Method | Cyclic execution, Periodic operation, Interrupt operation, Flxed scan | ||||
| I/O control method | Scan synchronized batch processing method (Refresh method) | ||||
| Program language | LD(Ladder Diagram), ST(Structured Text), SFC(Sequential Function Chart), IL(Read only) | ||||
| Number of Instructions | Operator | 18 | |||
| Standard function | 130 + Real type function | ||||
| Standard function block | 41 | ||||
| Special function/ function block | Special function block, Process control function block | ||||
| Processing speed | LD | 0.042 ㎲/Step | |||
| MOV | 0.126 ㎲/Step | ||||
| Real type | ± : 0.602㎲(S), 1.078㎲(D) X : 1.106㎲(S), 2.394㎲(D) ÷ : 1.134㎲(S), 2.66㎲(D) | S: Real type D: Long real type | |||
| I/O Points | I: 131,072 points, Q: 131,072 points (Total: 1131,072) | ||||
| DRAM | Program memory | 7MB | Including Upload, Parameter, Sytem area *Battery back-up memory: 8MB | ||
| Data memory | 2MB | ||||
| Reserved memory | 7MB | ||||
| Flash memory | 16MB | ||||
| Data memory | Direct variable | 256k Byte | |||
| Auto allocated variable | 512k Byte | ||||
| Timer | No limitation, Range: 0.001sec ~ 4,259,967.295sec (1,193hours) | ||||
| Counter | No limitation, Range: -32,768 ~ +32,767 | ||||
| Flag | System | 4k Byte | |||
| Comm- unication | 64k Byte | L, N area | |||
| Special | 2k Byte (32base, 16slot, 32channel) | U area: Analog device area | |||
| File register | 64k Byte *2 | R area: read/write (Command, XG5000) | |||
| Program | Number of program blocks | 256 | |||
| Initial task | 1 (_INT) | ||||
| Cycle task | 32 | ||||
| Internal device task | 32 | ||||
| Operation mode | RUN, STOP, DEBUG | ||||
| Restart mode | Warm, Cold | ||||
| Self diagnostic functions | Watchdog timer, Memory error, I/O error, Battery error, Power Supply error | ||||
| Program download | RS-232C (1CH), USB (1CH) | ||||
| Data retain | Auto allocated variable: set by variable definition Direct variable: set by parameter | ||||
| Max. expansion base | 31 stages | ||||
| Item | Hardware | Remarks | |
|---|---|---|---|
| CPU module | 2 slot / Fiber, Twisted fair | ||
| Expansion drive module | 1 slot / Fiber, Twisted fair, Hybrid | ||
| Base | Main base: 6 slot, Expansion base: 12 slot | ||
| Power | AC110V | 5V-5.5A | |
| AC220V | 5V-5.5A | ||
| AC110V | 5V-8.5A | ||
| AC220V | 5V-8.5A | ||
| Expansion method and Max. expansion base | 31 stages by network | ||
| Base number setting | Rotary switch of expansion drive module | ||
| Distance between expansion bases | Twisted fair: 100m (3km), Fiber: 2km (60km) | ||
| Master/Standby switching over time | 50ms or less | ||
Catalogues
- Catalog-LS ELECTRIC-PLC (Smart Automation Solution)-Factory Automation Brochure
- Catalog-LS ELECTRIC-PLC (Smart Automation Solution)-Leaflet for Smart I/O
- Catalog-LS ELECTRIC-PLC (Smart Automation Solution)-MOTION CONTROLLER XMC-E32A
- Catalog-LS ELECTRIC-PLC (Smart Automation Solution)-[PLC] Auto Products
- Catalog-LS ELECTRIC-PLC (Smart Automation Solution)-LSP Series (SMPS)
- Catalog-LS ELECTRIC-PLC (Smart Automation Solution)-Catalog for Smart Link Board
PLC XGR-CPU (XGT Series)
PLC XGR-CPU (XGT Series): overview and buying guide
The PLC XGR-CPU (XGT Series) is made by LS ELECTRIC and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the PLC XGR-CPU (XGT Series) cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the PLC XGR-CPU (XGT Series) to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine LS ELECTRIC product?
We purchase directly from LS ELECTRIC or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Features
High performance
ㆍProcessing speed: 42ns/step
ㆍCPU synchronization via fiber optic cable
ㆍI/O Points: Max. 131,072
ㆍTotal memory: 25MB (Program 3MB, System 4MB, Data 2MB, Flash 16MB)
ㆍSwitching over time: 22ms
Easy expansion installation using network
ㆍMax.31 expansion base
ㆍDistance: Fiber optic 2km (Max. expansion 60km), Twisted fair 100m (Max. expansion 3km)
ㆍProgram upload and download via expansion base
ㆍNo limit to install the communication master on the expansion base
Enhanced maintenance via system history and network ring configuration
ㆍConvenient system analyze using Operation history, Error history, System History
ㆍRing configuration to prevent a line disconnection error
ㆍNetwork monitoring, Protocol monitoring function
ㆍError channel monitoring via flag
ㆍGraphic display for the system configuration
ㆍSafe module exchange via Wizard
IEC 61131-3 Standard language
ㆍLD, ST, SFC, IL (read only)
ㆍProgram configuration and data type based on IEC
Specifications
| Item | Description | Remark | |||
|---|---|---|---|---|---|
| XGR-CPUH/F | XGR-CPUH/T | ||||
| Media | Fiber optic | Twisted pair | |||
| Operation Method | Cyclic execution, Periodic operation, Interrupt operation, Flxed scan | ||||
| I/O control method | Scan synchronized batch processing method (Refresh method) | ||||
| Program language | LD(Ladder Diagram), ST(Structured Text), SFC(Sequential Function Chart), IL(Read only) | ||||
| Number of Instructions | Operator | 18 | |||
| Standard function | 130 + Real type function | ||||
| Standard function block | 41 | ||||
| Special function/ function block | Special function block, Process control function block | ||||
| Processing speed | LD | 0.042 ㎲/Step | |||
| MOV | 0.126 ㎲/Step | ||||
| Real type | ± : 0.602㎲(S), 1.078㎲(D) X : 1.106㎲(S), 2.394㎲(D) ÷ : 1.134㎲(S), 2.66㎲(D) | S: Real type D: Long real type | |||
| I/O Points | I: 131,072 points, Q: 131,072 points (Total: 1131,072) | ||||
| DRAM | Program memory | 7MB | Including Upload, Parameter, Sytem area *Battery back-up memory: 8MB | ||
| Data memory | 2MB | ||||
| Reserved memory | 7MB | ||||
| Flash memory | 16MB | ||||
| Data memory | Direct variable | 256k Byte | |||
| Auto allocated variable | 512k Byte | ||||
| Timer | No limitation, Range: 0.001sec ~ 4,259,967.295sec (1,193hours) | ||||
| Counter | No limitation, Range: -32,768 ~ +32,767 | ||||
| Flag | System | 4k Byte | |||
| Comm- unication | 64k Byte | L, N area | |||
| Special | 2k Byte (32base, 16slot, 32channel) | U area: Analog device area | |||
| File register | 64k Byte *2 | R area: read/write (Command, XG5000) | |||
| Program | Number of program blocks | 256 | |||
| Initial task | 1 (_INT) | ||||
| Cycle task | 32 | ||||
| Internal device task | 32 | ||||
| Operation mode | RUN, STOP, DEBUG | ||||
| Restart mode | Warm, Cold | ||||
| Self diagnostic functions | Watchdog timer, Memory error, I/O error, Battery error, Power Supply error | ||||
| Program download | RS-232C (1CH), USB (1CH) | ||||
| Data retain | Auto allocated variable: set by variable definition Direct variable: set by parameter | ||||
| Max. expansion base | 31 stages | ||||
| Item | Hardware | Remarks | |
|---|---|---|---|
| CPU module | 2 slot / Fiber, Twisted fair | ||
| Expansion drive module | 1 slot / Fiber, Twisted fair, Hybrid | ||
| Base | Main base: 6 slot, Expansion base: 12 slot | ||
| Power | AC110V | 5V-5.5A | |
| AC220V | 5V-5.5A | ||
| AC110V | 5V-8.5A | ||
| AC220V | 5V-8.5A | ||
| Expansion method and Max. expansion base | 31 stages by network | ||
| Base number setting | Rotary switch of expansion drive module | ||
| Distance between expansion bases | Twisted fair: 100m (3km), Fiber: 2km (60km) | ||
| Master/Standby switching over time | 50ms or less | ||
Catalogues
- Catalog-LS ELECTRIC-PLC (Smart Automation Solution)-Factory Automation Brochure
- Catalog-LS ELECTRIC-PLC (Smart Automation Solution)-Leaflet for Smart I/O
- Catalog-LS ELECTRIC-PLC (Smart Automation Solution)-MOTION CONTROLLER XMC-E32A
- Catalog-LS ELECTRIC-PLC (Smart Automation Solution)-[PLC] Auto Products
- Catalog-LS ELECTRIC-PLC (Smart Automation Solution)-LSP Series (SMPS)
- Catalog-LS ELECTRIC-PLC (Smart Automation Solution)-Catalog for Smart Link Board