PLC MASTER-K Series (Software) KGL-WIN
KGL-WIN (Software)
Powerful & compact module-type PLC K200S & K300S are module-type PLC that consist of various modules including the basic module (CPU, Power, I/O), communication module, and special module. Through these various modules, the user can configure the optimal system for industry environment.
Features
Introduction
KGL-WIN is a software tool that programs and debugs all Master-K PLC series.
Features
1) Program Compatible between LS Master-K Series.
- The user can use the Program (*.PGM) created in LS Master-K Series for the program created in other LS Master-K Series as well. The Program, Parameter, or Variable/Comment created in KGL-DOS or GSIKGL can also be used in KGL for Windows.
2) PLC System Configuration by Project Structure
- KGL for Windows manages the User-Defined Program as one Project including Parameter and Variable/Comment. A user can also save a Program (*.PRG), Parameter (*.PMT), Variable (*.VAR) or Comment (*.CNT) and the stored file can be used for other project files.
3) User Friendly Interface
- Easy and useful interface for creating, editing, and monitoring.
4) Online Editing
- Real time editing is available in online mode. The program edited in the online condition can be downloaded automatically without stopping the PLC hardware.
5) Monitoring Information from the PLC
- A user can easily monitor the PLC status such as error status, network information, and system status.
6) Debugging and Self-diagnosis (in New MASTER-K Series)
- Trigger and Forced I/O enabling are available for accurate debugging.
Connection with PLC
To connect with the PLC, the user selects the method of connection and the depth of connection. The method of connection consists of 'Connection using RS-232C', 'Dial-up modem connection', 'Connection using communication module'. And the depth of connection consists of 'Local connection', 'Remote 1 connection', 'Remote 2 connection'. The basic connection option of KGL-WIN is set as RS-232C (COM1) And the connection option and the environment setting are saved along with the project.
RS-232C wiring
System Requirement
| Item | Specifications |
|---|---|
| OS | Windows 95 or later |
| PC | IBM compatible PC (50MHz or higher) |
| Memory | 8Mbyte or more |
| FDD | 3.5 Inch or 5.25 Inch |
| HDD | 20Mbyte or more |
| Serial port | RS-232 needed If you have a USB port only, You need to use USB-RS232C converter. |
| Print/Mouse | Compatible with Windows 95 or later |
Detailed specification sheets are shown in the product images.
Catalogues
- Catalog-LS ELECTRIC-PLC MASTER-K Series (Factory Automation Brochure)
- Catalog-LS ELECTRIC-PLC MASTER-K Series (MOTION CONTROLLER XMC-E32A)
- Catalog-LS ELECTRIC-PLC MASTER-K Series (Auto Products)
- Catalog-LS ELECTRIC-PLC MASTER-K Series (LSP Series (SMPS) brochure)
- Catalog-LS ELECTRIC-PLC MASTER-K Series
- Catalog-LS ELECTRIC-PLC MASTER-K Series Catalog for Smart Link Board
- Catalog-LS ELECTRIC-PLC MASTER-K Series (Leaflet for Smart I/O)
PLC MASTER-K Series (Software) KGL-WIN
PLC MASTER-K Series (Software) KGL-WIN: overview and buying guide
The PLC MASTER-K Series (Software) KGL-WIN (model KGL-WIN) is made by LS ELECTRIC and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the PLC MASTER-K Series (Software) KGL-WIN cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the PLC MASTER-K Series (Software) KGL-WIN to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine LS ELECTRIC product?
We purchase directly from LS ELECTRIC or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
KGL-WIN (Software)
Powerful & compact module-type PLC K200S & K300S are module-type PLC that consist of various modules including the basic module (CPU, Power, I/O), communication module, and special module. Through these various modules, the user can configure the optimal system for industry environment.
Features
Introduction
KGL-WIN is a software tool that programs and debugs all Master-K PLC series.
Features
1) Program Compatible between LS Master-K Series.
- The user can use the Program (*.PGM) created in LS Master-K Series for the program created in other LS Master-K Series as well. The Program, Parameter, or Variable/Comment created in KGL-DOS or GSIKGL can also be used in KGL for Windows.
2) PLC System Configuration by Project Structure
- KGL for Windows manages the User-Defined Program as one Project including Parameter and Variable/Comment. A user can also save a Program (*.PRG), Parameter (*.PMT), Variable (*.VAR) or Comment (*.CNT) and the stored file can be used for other project files.
3) User Friendly Interface
- Easy and useful interface for creating, editing, and monitoring.
4) Online Editing
- Real time editing is available in online mode. The program edited in the online condition can be downloaded automatically without stopping the PLC hardware.
5) Monitoring Information from the PLC
- A user can easily monitor the PLC status such as error status, network information, and system status.
6) Debugging and Self-diagnosis (in New MASTER-K Series)
- Trigger and Forced I/O enabling are available for accurate debugging.
Connection with PLC
To connect with the PLC, the user selects the method of connection and the depth of connection. The method of connection consists of 'Connection using RS-232C', 'Dial-up modem connection', 'Connection using communication module'. And the depth of connection consists of 'Local connection', 'Remote 1 connection', 'Remote 2 connection'. The basic connection option of KGL-WIN is set as RS-232C (COM1) And the connection option and the environment setting are saved along with the project.
RS-232C wiring
System Requirement
| Item | Specifications |
|---|---|
| OS | Windows 95 or later |
| PC | IBM compatible PC (50MHz or higher) |
| Memory | 8Mbyte or more |
| FDD | 3.5 Inch or 5.25 Inch |
| HDD | 20Mbyte or more |
| Serial port | RS-232 needed If you have a USB port only, You need to use USB-RS232C converter. |
| Print/Mouse | Compatible with Windows 95 or later |
Detailed specification sheets are shown in the product images.
Catalogues
- Catalog-LS ELECTRIC-PLC MASTER-K Series (Factory Automation Brochure)
- Catalog-LS ELECTRIC-PLC MASTER-K Series (MOTION CONTROLLER XMC-E32A)
- Catalog-LS ELECTRIC-PLC MASTER-K Series (Auto Products)
- Catalog-LS ELECTRIC-PLC MASTER-K Series (LSP Series (SMPS) brochure)
- Catalog-LS ELECTRIC-PLC MASTER-K Series
- Catalog-LS ELECTRIC-PLC MASTER-K Series Catalog for Smart Link Board
- Catalog-LS ELECTRIC-PLC MASTER-K Series (Leaflet for Smart I/O)