OptiMass 9600
It is GBC's 3rd generation latest ICP-oTOF MS, and simultaneously capable of analyzing all elements within the Mass Range, with a significant feature being reduced maintenance costs due to shortened analysis time. With this cutting-edge ICP-oTOF MS equipment as its flagship, GBC is further strengthening its marketing.
Features
• Mass range : 1 ~ 260 amu (m/z)
• Capable of simultaneously analyzing all elements within the Mass Range.
- Elements not considered during sample analysis can be reconfirmed later from the data.
- Although accurate quantification is difficult due to the lack of a calibration curve, the presence or absence of other elements can be checked within the data.
• The improved Octopole collision cell (OCC) can effectively remove interferences that may occur during analysis, enhancing analysis reliability and being useful for ultra-trace analysis.
• Provides stable mass spectrometry results with an improved vacuum system of a 260L/s turbopump.
• Shows isotopic ratio accuracy equivalent to TIMS.
• The world's only SIMULTANEOUS Time of Flight ICP-MS.
• Reduced maintenance costs.
- Analysis time is short due to 5 times faster analysis than Quadrupole ICP-MS, and Argon consumption is about 10 times less than Quadrupole Type ICP-MS.
• Even very small samples (1uL) can be analyzed using ETV.
• Optimal ICP-o TOF Mass for ppb ~ ppt analysis.
Catalogues
OptiMass 9600
OptiMass 9600: overview and buying guide
The OptiMass 9600 is made by YOUNGIN Chromass and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the OptiMass 9600 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the OptiMass 9600 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine YOUNGIN Chromass product?
We purchase directly from YOUNGIN Chromass or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
It is GBC's 3rd generation latest ICP-oTOF MS, and simultaneously capable of analyzing all elements within the Mass Range, with a significant feature being reduced maintenance costs due to shortened analysis time. With this cutting-edge ICP-oTOF MS equipment as its flagship, GBC is further strengthening its marketing.
Features
• Mass range : 1 ~ 260 amu (m/z)
• Capable of simultaneously analyzing all elements within the Mass Range.
- Elements not considered during sample analysis can be reconfirmed later from the data.
- Although accurate quantification is difficult due to the lack of a calibration curve, the presence or absence of other elements can be checked within the data.
• The improved Octopole collision cell (OCC) can effectively remove interferences that may occur during analysis, enhancing analysis reliability and being useful for ultra-trace analysis.
• Provides stable mass spectrometry results with an improved vacuum system of a 260L/s turbopump.
• Shows isotopic ratio accuracy equivalent to TIMS.
• The world's only SIMULTANEOUS Time of Flight ICP-MS.
• Reduced maintenance costs.
- Analysis time is short due to 5 times faster analysis than Quadrupole ICP-MS, and Argon consumption is about 10 times less than Quadrupole Type ICP-MS.
• Even very small samples (1uL) can be analyzed using ETV.
• Optimal ICP-o TOF Mass for ppb ~ ppt analysis.
