{"product_id":"multitrack-spectrometer-137174","title":"MultiTrack Spectrometer PoliSpectra® M116","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eMultispectra, Multifiber, Multichannel Imaging spectrometer with 8-16-32 Simultaneous UV-NIR Spectra\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eHORIBA designs and manufactures a large range of custom OEM fiber-coupled, multi-spectra spectrometers capable of simultaneous measurement of up to 32 fiber channels and sequential measurement up to 96. Utilizing a concentric imaging spectrometer with a broadband spectral range and a customized fiber bundle, the HORIBA OEM multifiber spectrometers provide excellent imaging quality with minimum crosstalk.\u003c\/p\u003e \u003cp\u003eThe PoliSpectra® MultiTrack systems feature high throughput\/ sensitivity and a 2D Scientific back-illuminated CMOS sensor which can be configured with 8,16 or 32 fiber input channels for simultaneous acquisition of UV-NIR spectra.\u003c\/p\u003e \u003cp\u003eWith an optional nitrogen purge, the system can be configured for low UV coverage. Additionally the high QE sCMOS sensor and an integrated order sorting filter allow wavelength coverage beyond 1 μm.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFor OEM Industrial Applications\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eㆍ Multitrack Spectroscopy\u003cbr\u003eㆍ Fluorescence, Emission and Reflectance\u003cbr\u003eㆍ Some examples from semiconductor applications to life sciences:\u003cbr\u003e - Quality Control\u003cbr\u003e - Light Source Calibration Monitoring\u003cbr\u003e - Plasma Monitoring\u003cbr\u003e - Blood\/DNA Multisampling\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cp\u003eㆍ Simultaneous measurement up to 32 fiber channels with minimal crosstalk\u003cbr\u003eㆍ Extended UV capability below 200 nm\u003cbr\u003eㆍ High spectral and spatial resolution combined with high throughput\u003cbr\u003eㆍ High speed and low noise sCMOS 2048 pixels sensor\u003cbr\u003eㆍ On-board processing capability using powerful dual-core ARM cortex and 2 GB memory\u003cbr\u003eㆍ USB 3 Interface\u003cbr\u003eㆍ Stable and robust\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eImage of 8-channel Fiber Bundle Illuminated with Hg and Ar Lamp\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eThroughput Differences and Crosstalk between Input Fiber Channels\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eScientific CMOS Back-Illuminated Sensor Quantum Efficiency\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eThermal stability study cycling from -20ºC to 50ºC\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHyperspectral Imaging Distortions: Keystone and Smile\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eOEM Spectrometer Selection Guide\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003e8-channel Spectrometer Specifications*\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSpectral Coverage\u003c\/td\u003e \u003ctd\u003e185 - 1050 nm (extension to low UV with N2 purge)\u003cbr\u003eTunable at factory between these ranges: 185-920 nm and 280-1050 nm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSpectrometer Input\u003c\/td\u003e \u003ctd\u003e8 channel, φ200 μm core fibers with φ220 μm clad, separated by a φ220 μm dead fiber\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSpectral Resolution\u003c\/td\u003e \u003ctd\u003e1.25 nm typical (22 μm slit width) and up, depending on the slit size\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSpectral Dispersion\u003c\/td\u003e \u003ctd\u003e34.6 nm\/mm; 0.38 nm\/pixel\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCrosstalk (Adjacent Channel)*\u003c\/td\u003e \u003ctd\u003e\u0026lt; 0.1% (measured @ 600 nm)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCrosstalk (Non-adjacent Channel)*\u003c\/td\u003e \u003ctd\u003e\u0026lt; 0.1% (measured @ 600 nm)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFocal Length\u003c\/td\u003e \u003ctd\u003e116 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF\/#\u003c\/td\u003e \u003ctd\u003eF\/2.3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSmile and Keystone\u003c\/td\u003e \u003ctd\u003e1.5 pixel (typical)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStray Light***\u003c\/td\u003e \u003ctd\u003e\u0026lt; 0.1% (typical)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWavelength Accuracy\u003c\/td\u003e \u003ctd\u003e0.1 nm (using 8 channel wavelength calibration)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSoftware\u003c\/td\u003e \u003ctd\u003eLabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth colspan=\"2\"\u003e16-channel and 32-channel Spectrometer Specifications\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSpectral Coverage\u003c\/td\u003e \u003ctd\u003e185 - 1050 nm (configurable based on customer’s need)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSpectrometer Input\u003c\/td\u003e \u003ctd\u003e16 channel, φ100 μm core fibers with φ110 μm clad\u003cbr\u003e32 channel, φ70 μm core fibers with φ77 μm clad\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSpectral Resolution\u003c\/td\u003e \u003ctd\u003e1 nm and up depending on fiber core size\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSpectral Dispersion\u003c\/td\u003e \u003ctd\u003e34.6 nm\/mm; 0.38 nm\/pixel\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFocal Length\u003c\/td\u003e \u003ctd\u003e116 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF\/#\u003c\/td\u003e \u003ctd\u003eF\/2.3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSmile and Keystone\u003c\/td\u003e \u003ctd\u003e1.5 pixel (typical)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStray Light\u003c\/td\u003e \u003ctd\u003e\u0026lt; 0.1% (typical)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWavelength Accuracy\u003c\/td\u003e \u003ctd\u003e0.1 nm (using 32 channel wavelength calibration)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth colspan=\"3\"\u003eSpecifications for Scientific Back-Illuminated CMOS Image Sensor with High Speed Electronics\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDetector Model\u003cbr\u003e \u003c\/td\u003e \u003ctd colspan=\"2\"\u003esCMOS BI sensor with electronic rolling shutter (all the parameters are specified at\u003cbr\u003enormal room temperature of 25º C unless otherwise noted)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSensor Format****\u003c\/td\u003e \u003ctd colspan=\"2\"\u003e2048 x 512\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCMOS Pixel Size \u003c\/td\u003e \u003ctd colspan=\"2\"\u003e11 μm x 11 μm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCMOS Height \u003c\/td\u003e \u003ctd colspan=\"2\"\u003e5.6 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCMOS QE\u003c\/td\u003e \u003ctd colspan=\"2\"\u003eThe peak QE is 77% at 250 nm and 95% at 560 nm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eThermoelectric Cooling \u003c\/td\u003e \u003ctd colspan=\"2\"\u003eUncooled\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Rate\u003c\/td\u003e \u003ctd colspan=\"2\"\u003e94 fps (HDR mode), 188 fps (STD mode) on 2D sCMOS sensor\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFull Well\u003c\/td\u003e \u003ctd colspan=\"2\"\u003e80 ke¯ typical (HDR mode)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eReadout Noise\u003c\/td\u003e \u003ctd colspan=\"2\"\u003e1.6 e¯ typical, 2.0 e¯ maximum\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDigitization\u003c\/td\u003e \u003ctd colspan=\"2\"\u003e16-bit (HDR mode), 12-bit (High Sensitivity mode)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDynamic Range\u003c\/td\u003e \u003ctd colspan=\"2\"\u003e 93.9 dB typical in HDR mode\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNon-linearity (measured on each system)\u003c\/td\u003e \u003ctd\u003e1.8% (maximum) in HDR mode\u003c\/td\u003e \u003ctd\u003e\u0026lt;0.9% (maximum) in High Sensitivity mode\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCommunication\u003c\/td\u003e \u003ctd colspan=\"2\"\u003e USB 3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnvironmental Conditions\u003cbr\u003e \u003c\/td\u003e \u003ctd colspan=\"2\"\u003eOperating temperature 15°C to 40°C ambient;\u003cbr\u003eRelative humidity \u0026lt;70% (non-condensing); Storage temperature -25°C to 45°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower requirements\u003cbr\u003eAC\/DC power supply (provided)\u003c\/td\u003e \u003ctd colspan=\"2\"\u003e90-264 VAC, 47–63 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e* Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW license is needed to run our acquisition software.\u003c\/p\u003e \u003cp\u003e** Crosstalk (to adjacent channels): the % of signal leaking to the adjacent channels while one channel is on and others are off.\u003c\/p\u003e \u003cp\u003e*** Stray light using BP Filter: Baseline light level, outside the band, divided by BP peak (unsaturated) value.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMechanical Drawings\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-1436a845fb35f180.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-Horiba-MultiTrack Spectrometer-M116\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-e44fabcd8a67afeb.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDrawing-Horiba-MultiTrack Spectrometer-M116\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HORIBA","offers":[{"title":"Default Title","offer_id":58446675673428,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/c890bd32-f812-4a75-aaa8-76c688697e14.jpg?v=1795191440","url":"https:\/\/premiumemart.com\/products\/multitrack-spectrometer-137174","provider":"Premium Emart","version":"1.0","type":"link"}