MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
New
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116
MultiTrack Spectrometer PoliSpectra® M116

MultiTrack Spectrometer PoliSpectra® M116

Overview


Multispectra, Multifiber, Multichannel Imaging spectrometer with 8-16-32 Simultaneous UV-NIR Spectra

HORIBA designs and manufactures a large range of custom OEM fiber-coupled, multi-spectra spectrometers capable of simultaneous measurement of up to 32 fiber channels and sequential measurement up to 96. Utilizing a concentric imaging spectrometer with a broadband spectral range and a customized fiber bundle, the HORIBA OEM multifiber spectrometers provide excellent imaging quality with minimum crosstalk.

The PoliSpectra® MultiTrack systems feature high throughput/ sensitivity and a 2D Scientific back-illuminated CMOS sensor which can be configured with 8,16 or 32 fiber input channels for simultaneous acquisition of UV-NIR spectra.

With an optional nitrogen purge, the system can be configured for low UV coverage. Additionally the high QE sCMOS sensor and an integrated order sorting filter allow wavelength coverage beyond 1 μm.

For OEM Industrial Applications

ㆍ Multitrack Spectroscopy
ㆍ Fluorescence, Emission and Reflectance
ㆍ Some examples from semiconductor applications to life sciences:
- Quality Control
- Light Source Calibration Monitoring
- Plasma Monitoring
- Blood/DNA Multisampling

Features

ㆍ Simultaneous measurement up to 32 fiber channels with minimal crosstalk
ㆍ Extended UV capability below 200 nm
ㆍ High spectral and spatial resolution combined with high throughput
ㆍ High speed and low noise sCMOS 2048 pixels sensor
ㆍ On-board processing capability using powerful dual-core ARM cortex and 2 GB memory
ㆍ USB 3 Interface
ㆍ Stable and robust

Image of 8-channel Fiber Bundle Illuminated with Hg and Ar Lamp

Throughput Differences and Crosstalk between Input Fiber Channels

Scientific CMOS Back-Illuminated Sensor Quantum Efficiency

Thermal stability study cycling from -20ºC to 50ºC

Hyperspectral Imaging Distortions: Keystone and Smile

OEM Spectrometer Selection Guide

Specifications

8-channel Spectrometer Specifications*
Spectral Coverage 185 - 1050 nm (extension to low UV with N2 purge)
Tunable at factory between these ranges: 185-920 nm and 280-1050 nm
Spectrometer Input 8 channel, φ200 μm core fibers with φ220 μm clad, separated by a φ220 μm dead fiber
Spectral Resolution 1.25 nm typical (22 μm slit width) and up, depending on the slit size
Spectral Dispersion 34.6 nm/mm; 0.38 nm/pixel
Crosstalk (Adjacent Channel)* < 0.1% (measured @ 600 nm)
Crosstalk (Non-adjacent Channel)* < 0.1% (measured @ 600 nm)
Focal Length 116 mm
F/# F/2.3
Smile and Keystone 1.5 pixel (typical)
Stray Light*** < 0.1% (typical)
Wavelength Accuracy 0.1 nm (using 8 channel wavelength calibration)
Software LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration)
16-channel and 32-channel Spectrometer Specifications
Spectral Coverage 185 - 1050 nm (configurable based on customer’s need)
Spectrometer Input 16 channel, φ100 μm core fibers with φ110 μm clad
32 channel, φ70 μm core fibers with φ77 μm clad
Spectral Resolution 1 nm and up depending on fiber core size
Spectral Dispersion 34.6 nm/mm; 0.38 nm/pixel
Focal Length 116 mm
F/# F/2.3
Smile and Keystone 1.5 pixel (typical)
Stray Light < 0.1% (typical)
Wavelength Accuracy 0.1 nm (using 32 channel wavelength calibration)
Specifications for Scientific Back-Illuminated CMOS Image Sensor with High Speed Electronics
Detector Model
sCMOS BI sensor with electronic rolling shutter (all the parameters are specified at
normal room temperature of 25º C unless otherwise noted)
Sensor Format**** 2048 x 512
CMOS Pixel Size 11 μm x 11 μm
CMOS Height 5.6 mm
CMOS QE The peak QE is 77% at 250 nm and 95% at 560 nm
Thermoelectric Cooling Uncooled
Frame Rate 94 fps (HDR mode), 188 fps (STD mode) on 2D sCMOS sensor
Full Well 80 ke¯ typical (HDR mode)
Readout Noise 1.6 e¯ typical, 2.0 e¯ maximum
Digitization 16-bit (HDR mode), 12-bit (High Sensitivity mode)
Dynamic Range 93.9 dB typical in HDR mode
Non-linearity (measured on each system) 1.8% (maximum) in HDR mode <0.9% (maximum) in High Sensitivity mode
Communication USB 3
Environmental Conditions
Operating temperature 15°C to 40°C ambient;
Relative humidity <70% (non-condensing); Storage temperature -25°C to 45°C
Power requirements
AC/DC power supply (provided)
90-264 VAC, 47–63 Hz

* Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW license is needed to run our acquisition software.

** Crosstalk (to adjacent channels): the % of signal leaking to the adjacent channels while one channel is on and others are off.

*** Stray light using BP Filter: Baseline light level, outside the band, divided by BP peak (unsaturated) value.

Mechanical Drawings

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

MultiTrack Spectrometer PoliSpectra® M116

MultiTrack Spectrometer PoliSpectra® M116

$0.00

MultiTrack Spectrometer PoliSpectra® M116: overview and buying guide

The MultiTrack Spectrometer PoliSpectra® M116 (model PoliSpectra® M116) is made by HORIBA and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the MultiTrack Spectrometer PoliSpectra® M116 cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the MultiTrack Spectrometer PoliSpectra® M116 to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine HORIBA product?

We purchase directly from HORIBA or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

Overview


Multispectra, Multifiber, Multichannel Imaging spectrometer with 8-16-32 Simultaneous UV-NIR Spectra

HORIBA designs and manufactures a large range of custom OEM fiber-coupled, multi-spectra spectrometers capable of simultaneous measurement of up to 32 fiber channels and sequential measurement up to 96. Utilizing a concentric imaging spectrometer with a broadband spectral range and a customized fiber bundle, the HORIBA OEM multifiber spectrometers provide excellent imaging quality with minimum crosstalk.

The PoliSpectra® MultiTrack systems feature high throughput/ sensitivity and a 2D Scientific back-illuminated CMOS sensor which can be configured with 8,16 or 32 fiber input channels for simultaneous acquisition of UV-NIR spectra.

With an optional nitrogen purge, the system can be configured for low UV coverage. Additionally the high QE sCMOS sensor and an integrated order sorting filter allow wavelength coverage beyond 1 μm.

For OEM Industrial Applications

ㆍ Multitrack Spectroscopy
ㆍ Fluorescence, Emission and Reflectance
ㆍ Some examples from semiconductor applications to life sciences:
- Quality Control
- Light Source Calibration Monitoring
- Plasma Monitoring
- Blood/DNA Multisampling

Features

ㆍ Simultaneous measurement up to 32 fiber channels with minimal crosstalk
ㆍ Extended UV capability below 200 nm
ㆍ High spectral and spatial resolution combined with high throughput
ㆍ High speed and low noise sCMOS 2048 pixels sensor
ㆍ On-board processing capability using powerful dual-core ARM cortex and 2 GB memory
ㆍ USB 3 Interface
ㆍ Stable and robust

Image of 8-channel Fiber Bundle Illuminated with Hg and Ar Lamp

Throughput Differences and Crosstalk between Input Fiber Channels

Scientific CMOS Back-Illuminated Sensor Quantum Efficiency

Thermal stability study cycling from -20ºC to 50ºC

Hyperspectral Imaging Distortions: Keystone and Smile

OEM Spectrometer Selection Guide

Specifications

8-channel Spectrometer Specifications*
Spectral Coverage 185 - 1050 nm (extension to low UV with N2 purge)
Tunable at factory between these ranges: 185-920 nm and 280-1050 nm
Spectrometer Input 8 channel, φ200 μm core fibers with φ220 μm clad, separated by a φ220 μm dead fiber
Spectral Resolution 1.25 nm typical (22 μm slit width) and up, depending on the slit size
Spectral Dispersion 34.6 nm/mm; 0.38 nm/pixel
Crosstalk (Adjacent Channel)* < 0.1% (measured @ 600 nm)
Crosstalk (Non-adjacent Channel)* < 0.1% (measured @ 600 nm)
Focal Length 116 mm
F/# F/2.3
Smile and Keystone 1.5 pixel (typical)
Stray Light*** < 0.1% (typical)
Wavelength Accuracy 0.1 nm (using 8 channel wavelength calibration)
Software LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration)
16-channel and 32-channel Spectrometer Specifications
Spectral Coverage 185 - 1050 nm (configurable based on customer’s need)
Spectrometer Input 16 channel, φ100 μm core fibers with φ110 μm clad
32 channel, φ70 μm core fibers with φ77 μm clad
Spectral Resolution 1 nm and up depending on fiber core size
Spectral Dispersion 34.6 nm/mm; 0.38 nm/pixel
Focal Length 116 mm
F/# F/2.3
Smile and Keystone 1.5 pixel (typical)
Stray Light < 0.1% (typical)
Wavelength Accuracy 0.1 nm (using 32 channel wavelength calibration)
Specifications for Scientific Back-Illuminated CMOS Image Sensor with High Speed Electronics
Detector Model
sCMOS BI sensor with electronic rolling shutter (all the parameters are specified at
normal room temperature of 25º C unless otherwise noted)
Sensor Format**** 2048 x 512
CMOS Pixel Size 11 μm x 11 μm
CMOS Height 5.6 mm
CMOS QE The peak QE is 77% at 250 nm and 95% at 560 nm
Thermoelectric Cooling Uncooled
Frame Rate 94 fps (HDR mode), 188 fps (STD mode) on 2D sCMOS sensor
Full Well 80 ke¯ typical (HDR mode)
Readout Noise 1.6 e¯ typical, 2.0 e¯ maximum
Digitization 16-bit (HDR mode), 12-bit (High Sensitivity mode)
Dynamic Range 93.9 dB typical in HDR mode
Non-linearity (measured on each system) 1.8% (maximum) in HDR mode <0.9% (maximum) in High Sensitivity mode
Communication USB 3
Environmental Conditions
Operating temperature 15°C to 40°C ambient;
Relative humidity <70% (non-condensing); Storage temperature -25°C to 45°C
Power requirements
AC/DC power supply (provided)
90-264 VAC, 47–63 Hz

* Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW license is needed to run our acquisition software.

** Crosstalk (to adjacent channels): the % of signal leaking to the adjacent channels while one channel is on and others are off.

*** Stray light using BP Filter: Baseline light level, outside the band, divided by BP peak (unsaturated) value.

Mechanical Drawings

Detailed specification sheets are shown in the product images.

Catalogues