GMS-2500 is multi-channel digital controller to monitor gas leakages from more than one gas detectors simultaneously. GMS-2000 is composed of one alarming unit & more than one receiving units. While each receiving units in GMS-2000 receive density signals from external gas detectors, when the density becomes higher than alarm value, receiving units automatically give signal to alarming unit to sound alarm.
GMS-2500 transmits the relay output and standard current output signal 4-20㎃ to various controllers such as PLC, DDC, recorders, and computers for composition of integrated gas monitoring system.
[ Features ]
ㆍ Centralized gas monitoring is available by connection with more than one gas detectors.
ㆍ Receiving 4-20㎃ analogue continuous signals from more than one gas detectors simultaneously and displaying the digital signals accurately by built-in high resolution A/D converter.
ㆍ User programming alarm range, alarm delay time, and so on, by built-in micro processor.
ㆍ Bar graph displays the alarming density for maximum visual effect.
ㆍ Built-in high resolution D/A converter for accurate transmission of 4-20㎃ standard current output signal to external controllers (PLC/DDC).
ㆍ High/low relay output for interlocking with external devices such as fan.
ㆍ Robust aluminum alloy casing & frame.
[ Specification ]
| Division | 1.1.1.1. GMS-2500 | |
| Alarming unit (Power unit) | ±1% of reading or 1℃ | |
| Product structure | DIN TYPE | DIN TYPE |
| Control structure. | Alarm:Indicator1:1~64 | Indicator: Sensor = 1:1 |
| Expansion structure. | Slide Card Type | |
| Input power | AC 230V/60Hz | |
| Output power | DC 24V(250㎃) | |
| Input signal | 4~20㎃ DC/F.S | |
| Output signal | 4~20㎃ DC/F.S, RS-485(Option) | |
| Density indicating | F.N.D Display %LEL(combustible),% (O2), PPM(toxic) | |
| Power indicating | Power supply indicating – POWER LED(GREEN) | |
| Alarm indicating | Alarm method | Low Alarm - LOW LED(RED) |
| High Alarm – HIGH LED(RED) | ||
| Trouble Alarm – FAULT LED(YELLOW) | ||
| Alarm method | Seeing – ALARM LED On/Off | Seeing – Alarm LED On/Off |
| Hearing– Buzz(higher than 80㏈) | ||
| Alarm density | HIGH/LOW 2 step Alarm density –set by user. | |
| Alarm delay time | 0~99seconds, setting by user | |
| Alarm lifting | Manual and automatic returning | |
| Alarm output | SPDT RELAY output for HIGH/LOW 2 steps SPDT RELAY output for FALULT alarm | |
| Operating temp./humidity | -20℃ ~ 50℃, 5 ~ 95%RH(Non-Condensing) | |
| Exterior structure. | 19”(3U) Unit - Aluminum, Outer box of system - Metal Case | |
| Output option | RS-485 | |
Catalogues
Multi-Channel Digital Controller GMS2000
Multi-Channel Digital Controller GMS2000: overview and buying guide
The Multi-Channel Digital Controller GMS2000 (model GMS2000) is made by GASDNA and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Multi-Channel Digital Controller GMS2000 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Multi-Channel Digital Controller GMS2000 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine GASDNA product?
We purchase directly from GASDNA or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
GMS-2500 is multi-channel digital controller to monitor gas leakages from more than one gas detectors simultaneously. GMS-2000 is composed of one alarming unit & more than one receiving units. While each receiving units in GMS-2000 receive density signals from external gas detectors, when the density becomes higher than alarm value, receiving units automatically give signal to alarming unit to sound alarm.
GMS-2500 transmits the relay output and standard current output signal 4-20㎃ to various controllers such as PLC, DDC, recorders, and computers for composition of integrated gas monitoring system.
[ Features ]
ㆍ Centralized gas monitoring is available by connection with more than one gas detectors.
ㆍ Receiving 4-20㎃ analogue continuous signals from more than one gas detectors simultaneously and displaying the digital signals accurately by built-in high resolution A/D converter.
ㆍ User programming alarm range, alarm delay time, and so on, by built-in micro processor.
ㆍ Bar graph displays the alarming density for maximum visual effect.
ㆍ Built-in high resolution D/A converter for accurate transmission of 4-20㎃ standard current output signal to external controllers (PLC/DDC).
ㆍ High/low relay output for interlocking with external devices such as fan.
ㆍ Robust aluminum alloy casing & frame.
[ Specification ]
| Division | 1.1.1.1. GMS-2500 | |
| Alarming unit (Power unit) | ±1% of reading or 1℃ | |
| Product structure | DIN TYPE | DIN TYPE |
| Control structure. | Alarm:Indicator1:1~64 | Indicator: Sensor = 1:1 |
| Expansion structure. | Slide Card Type | |
| Input power | AC 230V/60Hz | |
| Output power | DC 24V(250㎃) | |
| Input signal | 4~20㎃ DC/F.S | |
| Output signal | 4~20㎃ DC/F.S, RS-485(Option) | |
| Density indicating | F.N.D Display %LEL(combustible),% (O2), PPM(toxic) | |
| Power indicating | Power supply indicating – POWER LED(GREEN) | |
| Alarm indicating | Alarm method | Low Alarm - LOW LED(RED) |
| High Alarm – HIGH LED(RED) | ||
| Trouble Alarm – FAULT LED(YELLOW) | ||
| Alarm method | Seeing – ALARM LED On/Off | Seeing – Alarm LED On/Off |
| Hearing– Buzz(higher than 80㏈) | ||
| Alarm density | HIGH/LOW 2 step Alarm density –set by user. | |
| Alarm delay time | 0~99seconds, setting by user | |
| Alarm lifting | Manual and automatic returning | |
| Alarm output | SPDT RELAY output for HIGH/LOW 2 steps SPDT RELAY output for FALULT alarm | |
| Operating temp./humidity | -20℃ ~ 50℃, 5 ~ 95%RH(Non-Condensing) | |
| Exterior structure. | 19”(3U) Unit - Aluminum, Outer box of system - Metal Case | |
| Output option | RS-485 | |