{"product_id":"motorized-actuators-129680","title":"Motorized Actuators 3100R","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e▶ 3100R\/3200R\/3300R\/3400R\/3400L\/3420R\/3420L\/3900R: Motorized Actuators\u003c\/p\u003e\u003cp\u003eHere is a line-up of motor-operated actuators of basically ON\/OFF control. 3100 series is featured by small-size, lightweight and high output. 3400 series and 3420 series use case, cover, mounting portion, etc. commonly with a full-electronic actuator. \u003c\/p\u003e\u003cp\u003e3900 series can be used for an inexpensive and simple instrumentation, with a potentiate mounted for detection of control position, besides small size and lightweight. Explosion-proof approved models are also replete. \u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e3100R Rotary stem motion type\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003ePrincipal uses\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e2-position control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDrive motor\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSynchronous motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSingle phase 100\/110\/200\/220V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMotor rating\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e10 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eControl mechanism\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInput signal\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSwitching contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003eAncillary mechanism\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWith built-in thermal protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSpace heater- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003eConditions for installation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-10 to 50°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature- With space heater\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-20 to 40°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMounting position\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eShould not be mounted in an inverted position from the maintenance face.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003eBody portion\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eExternal sheath type\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProtection class IP65 or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWiring port\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eG1\/2 (1 place)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWiring port- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVarious adaptors can be mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInstallation seat\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eConforms to ISO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e\u003cbr\u003e\u003cp\u003e3200R Rotary stem motion type\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003ePrincipal uses\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e2-position control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDrive motor\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAC reversible motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSingle phase 100V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower supply- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSingle phase 110\/200\/220V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMotor rating\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003eControl mechanism\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInput signal\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSwitching contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOpening signal transmission- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePotentiometer (5kΩ\/135Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003eAncillary mechanism\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eControl position detection- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAuxiliary limit switch (voltfree), maximum points of detection 2 places\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWith built-in thermal protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSpace heater- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e* Please contact us for details, as this matter depends on the power supply voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003eConditions for installation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-10 to 50°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature- With space heater\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-20 to 40°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMounting position\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eShould not be mounted in an inverted position from the maintenance face.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003eBody portion\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eExternal sheath type\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProtection class IP65 or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWiring port\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eG1\/2 (1 place)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWiring port- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVarious adaptors can be mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInstallation seat\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eConforms to ISO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e\u003cbr\u003e\u003cp\u003e3300R Rotary stem motion type\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003ePrincipal uses\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e2-position control \/ Endless control \/ Multi-revolution control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDrive motor\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAC reversible motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSingle phase 100V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMotor rating\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003eControl mechanism\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInput signal\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSwitching contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInput signal- With control pack\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4 to 20mA DC or 1 to 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOpening signal transmission- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePotentiometer (5KΩ\/135Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"5\"\u003eAncillary mechanism\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eControl positiondetection-Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAuxiliary limit switch (voltfree), maximum points of detection 2 places\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDismountable handle type,wit clutch- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDismountable handle type, wit clutch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWith built-in thermal protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSpace heater- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e* Please contact us for details, as this matter depends on the power supply voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eControl- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eControl pack (endless type cannot be mounted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003eConditions for installation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-10 to 50°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature- With space heater\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-20 to 40°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMounting position\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eShould not be mounted in an inverted position from the maintenance face.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003eBody portion\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eExternal sheath type\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProtection class IP55 or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWiring port\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eG1\/2 (1 place)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWiring port- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVarious adaptors can be mounted,Terminal box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInstallation seat\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eConforms to ISO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e\u003cbr\u003e\u003cp\u003e3400R Rotary stem motion type\/3400L Linear stem motion type\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003ePrincipal uses\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e2-position control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDrive motor\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAC reversible motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSingle phase 100V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower supply- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSingle phase 110\/200\/220V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMotor rating\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003eControl mechanism\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInput signal\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSwitching contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOpening signal transmission- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePotentiometer (5KΩ\/135Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"5\"\u003eAncillary mechanism\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eControl position detection- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAuxiliary limit switch (voltfree), maximum points of detection 2 places\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDismountable handle type\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDismountable handle type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWith built-in thermal protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOverload protection- Optional (3400R)\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTorque switch on closed side (CW direction only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSpace heater- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e* Please contact us for details, as this matter depends on the power supply voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003eConditions for installation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-10 to 50°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature- With space heater\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-20 to 40°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMounting position\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eShould not be mounted in an inverted position from the maintenance face.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003eBody portion\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eExternal sheath type\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProtection class IP55 or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWiring port\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eG3\/4 (3400R) G1\/2 (3400L) 2 places\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWiring port- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVarious adaptors can be mountedTerminal box (3400L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInstallation seat\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eConforms to ISO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e\u003cbr\u003e\u003cp\u003e3420R Rotary stem motion type\/3420L Linear stem motion type\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003ePrincipal uses\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e2-position control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDrive motor\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAC reversible motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSingle phase 100\/110V AC 50\/60Hz (+\/- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower supply- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSingle phase 200\/220V AC 50\/60Hz (+\/- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMotor rating\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003eControl mechanism\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInput signal\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSwitching contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOpening signal transmission- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePotentiometer (5KΩ\/135Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003eAncillary mechanism\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eControl position detection- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAuxiliary limit switch (voltfree), maximum points of detection 2 places\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDismountable handle type\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWith handle insertion hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWith built-in thermal protector,Torque switch (3420R is an option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSpace heater- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e* Please contact us for details, as this matter depends on the power supply voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003eConditions for installation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-10 to 50°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature- With space heater\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-20 to 40°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMounting position\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eShould not be mounted in an inverted position from the maintenance face.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003eBody portion\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWiring port\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eG1\/2 (2 places)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWiring port- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVarious adaptors can be mountedTerminal box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInstallation seat\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eConforms to ISO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e\u003cbr\u003e\u003cp\u003e3900R Rotary stem motion type\u003cbr\u003e\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003ePrincipal uses\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e2-position control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDrive motor\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAC reversible motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSingle phase 100\/110V AC 50\/60Hz (+\/- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower supply- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSingle phase 200\/220V AC 50\/60Hz (+\/- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMotor rating\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003eControl mechanism\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInput signal\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSwitching contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOpening signal transmission- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePotentiometer (1KΩ\/135Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003eAncillary mechanism\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eControl position detection- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAuxiliary limit switch (voltfree), maximum points of detection 2 places\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDismountable handle type\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWith handle insertion hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWith built-in thermal protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSpace heater- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e* Please contact us for details, as this matter depends on the power supply voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003eConditions for installation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-10 to 50°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature- With space heater\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-20 to 40°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMounting position\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eShould not be mounted in an inverted position from the maintenance face.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003eBody portion\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eExternal sheath type\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProtection class IP65 or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWiring port\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eG1\/2 (2 places)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWiring port- Optional\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVarious adaptors can be mounted,Terminal box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInstallation seat\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eConforms to ISO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e","brand":"KOREA KOSO","offers":[{"title":"Default Title","offer_id":58446376534356,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/korea-koso_129680_dacubh.jpg?v=1795190761","url":"https:\/\/premiumemart.com\/products\/motorized-actuators-129680","provider":"Premium Emart","version":"1.0","type":"link"}