{"product_id":"mini-raman-spectrometers-137181","title":"Mini Raman Spectrometers CiCi-Raman-NIR","description":"\u003ch3\u003eOverview\u003c\/h3\u003e \u003cp\u003eHORIBA Scientific is the world leader in Raman spectroscopy, with a long history in the technique. HORIBA OEM has pioneered Raman systems for spectroscopy, designing and manufacturing them for over four decades. We provide miniature spectrometers and systems for industrial applications such as process control, security, pharmaceutical, medical and semiconductor. The CiCi-Raman-785 is our high performance spectrometer featuring an aberration-corrected concave holographic grating configured with Horiba Scientific's Syncerity™ TE-cooled CCD camera with a VIS-NIR 2048 x 70 detector, in a TE-cooled Head at -50° C.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFor OEM Industrial Applications\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eㆍ Process Control\u003cbr\u003eㆍ Pharmaceuticals and Cosmetics\u003cbr\u003eㆍ Geology and Mineralogy\u003cbr\u003eㆍ Carbon Materials\u003cbr\u003eㆍ Life Sciences\u003cbr\u003eㆍ Forensic and Security\u003cbr\u003eㆍ Semiconductor\u003cbr\u003eㆍ Food and Beverage Safety\u003c\/p\u003e \u003ch3\u003eFeatures\u003c\/h3\u003e\u003cp\u003eㆍ Rugged design for ultra-high stability and in-situ monitoring\u003cbr\u003eㆍ Deep cooled CCD with high quantum efficiency\u003cbr\u003eㆍ Super long exposure time\u003cbr\u003eㆍ High resolution of \u0026lt; 0.6 nm selectable resolution and throughput\u003cbr\u003eㆍ Competitively priced\u003cbr\u003eㆍ Available for 785 nm and 532 nm excitation wavelengths\u003cbr\u003eㆍ Stable and robust\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eQuantum Efficiency of the CCD Detector\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eOEM Spectrometer Selection Guide\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eGeneral Compact Raman Spectrometer Specifications\u003c\/strong\u003e\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eSpectral Coverage\u003c\/td\u003e \u003ctd\u003e785 - 1060 nm (Also available: 532 nm optimized spectrometer)\u003cbr\u003e150 to \u0026gt; 3300 cm\u003csup\u003e-1\u003c\/sup\u003e (Note: low limit depends on Raman probe)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSpectrometer Input\u003c\/td\u003e \u003ctd\u003e0.1 NA fiber for F\/5 version\u003cbr\u003e0.22 NA fiber for F\/2.3 version\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSpectral Resolution (at F\/5)\u003c\/td\u003e \u003ctd\u003e\u0026lt; 0.6 nm from 780 nm to 965 nm \u003cbr\u003e\u0026lt; 1.5 nm from 965 nm to 1,060 nm \u003cbr\u003e6 cm-1 at 1777 cm\u003csup\u003e-1\u003c\/sup\u003e \u003cbr\u003e7 cm-1 at 2518 cm\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFocal Length\u003c\/td\u003e \u003ctd\u003e140 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOptical Dispersion\u003c\/td\u003e \u003ctd\u003e9.77 nm\/mm; 0.137 nm\/pixel\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStray Light\u003c\/td\u003e \u003ctd\u003e\u0026lt; 0.1% (typical) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWavelength Accuracy\u003c\/td\u003e \u003ctd\u003e0.025 nm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF#\u003c\/td\u003e \u003ctd\u003eF\/2.3 (for highest sensitivity)\u003cbr\u003eF\/5 (for the most compact and highest resolution configuration)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSoftware\u003c\/td\u003e \u003ctd\u003eBasic LabVIEW acquisition software for evaluation.\u003cbr\u003eSee our optional LabSpec software.\u003cbr\u003e(DLLs provided for software integration)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eOEM SYNCERITY™ Scientific Camera with 2048 x 70 – VIS-NIR Optimized CCD*\u003c\/strong\u003e\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eQuantum Efficiency at 20° C\u003c\/td\u003e \u003ctd\u003eNew VIS-NIR Optimized CCD (Also available: 532 nm optimized spectrometer)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCCD Sensor Format\u003c\/td\u003e \u003ctd\u003e2048 x 70\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCCD Pixel Size\u003c\/td\u003e \u003ctd\u003e14 x 14 µm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCCD Height\u003c\/td\u003e \u003ctd\u003e1 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCCD QE at 20° C\u003c\/td\u003e \u003ctd\u003e60% at 500 nm; 80% at 600 nm; 80% at 800 nm\u003cbr\u003e68% at 900 nm; 42% at 1000 nm; 20% at 1,060 nm\u003cbr\u003eSee curve below\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDeep Thermoelectric Cooling\u003c\/td\u003e \u003ctd\u003e-50° C @ +25° C ambient or -40° C @ +40° C ambient.\u003cbr\u003eYields low dark current suitable for most OEM and many research applications\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSingle Pixel Well Capacity\u003c\/td\u003e \u003ctd\u003e50,000 e¯\/pixel (minimum); 60 000 e¯\/pixel (typical)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSerial Register Full Well Capacity\u003c\/td\u003e \u003ctd\u003e250,000 e¯\/pixel (minimum); 500 000 e¯\/pixel (typical output register saturation)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eScan Rates\u003c\/td\u003e \u003ctd\u003e45 kHz and 500 kHz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eReadout Noise (at 45 kHz and at –45° C)\u003c\/td\u003e \u003ctd\u003e10 e¯ (typical) to 12 e¯ (maximum)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eReadout Noise (at 500 kHz and at –45° C)\u003c\/td\u003e \u003ctd\u003e20 e¯ (typical) to 25 e¯ (maximum)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDynamic Range (typical)\u003c\/td\u003e \u003ctd\u003e55,500:1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMaximum Spectral Rate\u003c\/td\u003e \u003ctd\u003e20 Hz at 45 kHz scan rate; 189 Hz at 500 kHz scan rate\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDigitization\u003c\/td\u003e \u003ctd\u003e16-bit ADC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNon-linearity (measured on each camera)\u003c\/td\u003e \u003ctd\u003e\u0026lt;0.15% (typical) at 45 kHz (0.4% maximum)\u003cbr\u003e\u0026lt;0.20% (typical) at 500 kHz (1% maximum)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDark Current at –45° C \u003cbr\u003eNote: Pixel Size = 14 μm\u003c\/td\u003e \u003ctd\u003e0.025 e–\/pixel\/s (typical)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSoftware-adjustable Gains\u003c\/td\u003e \u003ctd\u003e2, 4, and 10 e–\/count at –50° C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCommunication\u003c\/td\u003e \u003ctd\u003eUSB 2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnvironmental Conditions\u003c\/td\u003e \u003ctd\u003eOperating temperature 0° C to 40° C ambient\u003cbr\u003eRelative humidity \u0026lt;70% (non-condensing)\u003cbr\u003eStorage temperature -25° C to 45° C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Requirements\u003cbr\u003eAC\/DC Power Supply (provided)\u003c\/td\u003e \u003ctd\u003e90-264 VAC, 47–63 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eQuantum Efficiency of the CCD Detector\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMechanical Drawings\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-3b9ff126c35aed55.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-Horiba-CiCi-Raman-NIR Spectrometer\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-28cf7975aac9bb7d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-Horiba-CiCi-Raman-NIR Spectrometer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HORIBA","offers":[{"title":"Default Title","offer_id":58446679310676,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/81bec381-24bc-4194-8998-eebe5dccdec7.jpg?v=1795191448","url":"https:\/\/premiumemart.com\/products\/mini-raman-spectrometers-137181","provider":"Premium Emart","version":"1.0","type":"link"}