 - The smallest digital power regulator :

  26mm width - Single phase / 115mm width – three phase

- Suitable for replacing SSR which has no protecting device. SCR module equipped in Mini is far more durable and reliable than TRIAC in SSR.

- Improved safety through alarming SCR failure which SSR can not detect

- Stable, Reliable and Convenient

Features

Comparison between Mini and SSR

Content Mini SSR Remark
Load failure alarm Basically installed Should attach additional C/T outside or load failure detector Mini has own C/T inside
Over current alarm Basically installed None Output current is more than 100% of its rated current
Over temperature alarm 60℃ Warning, 80℃ Alarm Mechanical contact
Power module failure alarm Basically installed None
Input signal Select one among 4~20mA / 0~10VDC / SSR SSR Select on ordering
Alarm point Basically 2points (Warning 1, Alarm 1) None
Display One three color LED displaying operation status and alarm LED displaying operation status
PCB Power 10~30VDC None


Stability, reliability and convenience

- When power module is failed, electric power to heater is not controlled at full power, which can cause a fire.

- Thus, to detect power module failure is very important to safety directly. Mini equipped with its own CT and CPU secures safety. This is different from SSR which can not detect power module failure.

- In case of SSR, additional device as CT or load failure detector should be attached to detect load failure. But Mini has its own CT, so no need to install any other device which can save labor cost and remove unnecessary wiring job. Eventually, it maximizes convenience.

- Control accuracy is enhanced with compensation algorithm.

- Long period of experience in digital power regulator allows Mini to satisfy stability and reliability.

Ordering Code

① NO. of phase PS : Mini single phase      TS : Mini three phase
② Rated current Single phase 010 : 10A / 025 : 25A / 040 : 40A
Three phase 025 : 25A / 040 : 40A / 055 : 55A / 070 : 70A
③ Input signal I : 4~20mA / V : 0~10VDC / S : SSR
④ Cooling fan Single phase NONE : Without cooling fan (Cooling fan can not be attached on 10A and 25A)
FN : With cooling fan (Only on 40A)
Three phase NONE : Without cooling fan
FN : With cooling fan (40A, 55A & 70A Cooling fan is basically installed)


Specification

Model Mini (Single phase) Mini (Three phase)
Rated voltage 50~500VAC 50~500VAC
Rated current 10A / 25A / 40A 25A / 40A / 55A/ 70A
Frequency 50/60Hz (Auto selectable) 50/60Hz (Auto selectable)
Minimum load 1A 1A
Output range Zero-Crossing 0~98% Zero-Crossing 0~98%
PCB power source 10~30VDC 10~30VDC
Input signal Select one among 4~20mA / 0~10VDC / SSR Select one among 4~20mA / 0~10VDC / SSR
Output NPN Open collector 2CH (Vc 〈 30V, Ic ≤ 50mA) NPN Open collector 2CH (Vc 〈 30V, Ic ≤ 50mA)
Control Method Zero-Crossing control with compensation algorithm Zero-Crossing control with compensation algorithm
Cooling 10A, 25A, 40A : Natural cooling /
40A Cooing fan (Option)
25A : Natural cooling (Cooling fan - Option) /
40A, 55A, 70A : Cooling fan installed
Alarm Over Current, Over Temperature of heatsink(60℃, 80℃),
Load Failure, SCR failure
Over Current, Over Temperature of heatsink(60℃, 80℃),
Load Failure, SCR failure, Unbalanced Load
Ambient Temp. 0 ~ 40℃ 0 ~ 40℃
Humidity 40% ~ 85% RH (No condensation) 40% ~ 85% RH (No condensation)
Display One three color LED One three color LED, Three single color LED’s
NET WT. 10A, 25A : 287g /
40A(Without fan) : 431g / 40A(With fan) : 454g
25A : 970g(Without fan) /
40A, 55A, 70A : 1.4Kgs (With fan)
Installation Bolt or DIN-rail Bolt
※ Please install rapid fuse outside of Mini for safety reason.

Detailed specification sheets are shown in the product images.

Error product group when enable variant picker

Availability: In stock
Categories: Electronic
Mini Power Regulator

Mini Power Regulator

$0.00

Mini Power Regulator: overview and buying guide

The Mini Power Regulator is made by PARA ENT and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Mini Power Regulator cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Mini Power Regulator to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine PARA ENT product?

We purchase directly from PARA ENT or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

 - The smallest digital power regulator :

  26mm width - Single phase / 115mm width – three phase

- Suitable for replacing SSR which has no protecting device. SCR module equipped in Mini is far more durable and reliable than TRIAC in SSR.

- Improved safety through alarming SCR failure which SSR can not detect

- Stable, Reliable and Convenient

Features

Comparison between Mini and SSR

Content Mini SSR Remark
Load failure alarm Basically installed Should attach additional C/T outside or load failure detector Mini has own C/T inside
Over current alarm Basically installed None Output current is more than 100% of its rated current
Over temperature alarm 60℃ Warning, 80℃ Alarm Mechanical contact
Power module failure alarm Basically installed None
Input signal Select one among 4~20mA / 0~10VDC / SSR SSR Select on ordering
Alarm point Basically 2points (Warning 1, Alarm 1) None
Display One three color LED displaying operation status and alarm LED displaying operation status
PCB Power 10~30VDC None


Stability, reliability and convenience

- When power module is failed, electric power to heater is not controlled at full power, which can cause a fire.

- Thus, to detect power module failure is very important to safety directly. Mini equipped with its own CT and CPU secures safety. This is different from SSR which can not detect power module failure.

- In case of SSR, additional device as CT or load failure detector should be attached to detect load failure. But Mini has its own CT, so no need to install any other device which can save labor cost and remove unnecessary wiring job. Eventually, it maximizes convenience.

- Control accuracy is enhanced with compensation algorithm.

- Long period of experience in digital power regulator allows Mini to satisfy stability and reliability.

Ordering Code

① NO. of phase PS : Mini single phase      TS : Mini three phase
② Rated current Single phase 010 : 10A / 025 : 25A / 040 : 40A
Three phase 025 : 25A / 040 : 40A / 055 : 55A / 070 : 70A
③ Input signal I : 4~20mA / V : 0~10VDC / S : SSR
④ Cooling fan Single phase NONE : Without cooling fan (Cooling fan can not be attached on 10A and 25A)
FN : With cooling fan (Only on 40A)
Three phase NONE : Without cooling fan
FN : With cooling fan (40A, 55A & 70A Cooling fan is basically installed)


Specification

Model Mini (Single phase) Mini (Three phase)
Rated voltage 50~500VAC 50~500VAC
Rated current 10A / 25A / 40A 25A / 40A / 55A/ 70A
Frequency 50/60Hz (Auto selectable) 50/60Hz (Auto selectable)
Minimum load 1A 1A
Output range Zero-Crossing 0~98% Zero-Crossing 0~98%
PCB power source 10~30VDC 10~30VDC
Input signal Select one among 4~20mA / 0~10VDC / SSR Select one among 4~20mA / 0~10VDC / SSR
Output NPN Open collector 2CH (Vc 〈 30V, Ic ≤ 50mA) NPN Open collector 2CH (Vc 〈 30V, Ic ≤ 50mA)
Control Method Zero-Crossing control with compensation algorithm Zero-Crossing control with compensation algorithm
Cooling 10A, 25A, 40A : Natural cooling /
40A Cooing fan (Option)
25A : Natural cooling (Cooling fan - Option) /
40A, 55A, 70A : Cooling fan installed
Alarm Over Current, Over Temperature of heatsink(60℃, 80℃),
Load Failure, SCR failure
Over Current, Over Temperature of heatsink(60℃, 80℃),
Load Failure, SCR failure, Unbalanced Load
Ambient Temp. 0 ~ 40℃ 0 ~ 40℃
Humidity 40% ~ 85% RH (No condensation) 40% ~ 85% RH (No condensation)
Display One three color LED One three color LED, Three single color LED’s
NET WT. 10A, 25A : 287g /
40A(Without fan) : 431g / 40A(With fan) : 454g
25A : 970g(Without fan) /
40A, 55A, 70A : 1.4Kgs (With fan)
Installation Bolt or DIN-rail Bolt
※ Please install rapid fuse outside of Mini for safety reason.

Detailed specification sheets are shown in the product images.