Mini Power Regulator
- The smallest digital power regulator :
26mm width - Single phase / 115mm width – three phase
- Suitable for replacing SSR which has no protecting device. SCR module equipped in Mini is far more durable and reliable than TRIAC in SSR.
- Improved safety through alarming SCR failure which SSR can not detect
- Stable, Reliable and Convenient
Features
Comparison between Mini and SSR
| Content | Mini | SSR | Remark |
|---|---|---|---|
| Load failure alarm | Basically installed | Should attach additional C/T outside or load failure detector | Mini has own C/T inside |
| Over current alarm | Basically installed | None | Output current is more than 100% of its rated current |
| Over temperature alarm | 60℃ Warning, 80℃ Alarm | Mechanical contact | |
| Power module failure alarm | Basically installed | None | |
| Input signal | Select one among 4~20mA / 0~10VDC / SSR | SSR | Select on ordering |
| Alarm point | Basically 2points (Warning 1, Alarm 1) | None | |
| Display | One three color LED displaying operation status and alarm | LED displaying operation status | |
| PCB Power | 10~30VDC | None |
Stability, reliability and convenience
- When power module is failed, electric power to heater is not controlled at full power, which can cause a fire.
- Thus, to detect power module failure is very important to safety directly. Mini equipped with its own CT and CPU secures safety. This is different from SSR which can not detect power module failure.
- In case of SSR, additional device as CT or load failure detector should be attached to detect load failure. But Mini has its own CT, so no need to install any other device which can save labor cost and remove unnecessary wiring job. Eventually, it maximizes convenience.
- Control accuracy is enhanced with compensation algorithm.
- Long period of experience in digital power regulator allows Mini to satisfy stability and reliability.
Ordering Code
| ① NO. of phase | PS : Mini single phase TS : Mini three phase |
| ② Rated current | Single phase 010 : 10A / 025 : 25A / 040 : 40A Three phase 025 : 25A / 040 : 40A / 055 : 55A / 070 : 70A |
| ③ Input signal | I : 4~20mA / V : 0~10VDC / S : SSR |
| ④ Cooling fan | Single phase NONE : Without cooling fan (Cooling fan can not be attached on 10A and 25A) FN : With cooling fan (Only on 40A) Three phase NONE : Without cooling fan FN : With cooling fan (40A, 55A & 70A Cooling fan is basically installed) |
Specification
| Model | Mini (Single phase) | Mini (Three phase) |
|---|---|---|
| Rated voltage | 50~500VAC | 50~500VAC |
| Rated current | 10A / 25A / 40A | 25A / 40A / 55A/ 70A |
| Frequency | 50/60Hz (Auto selectable) | 50/60Hz (Auto selectable) |
| Minimum load | 1A | 1A |
| Output range | Zero-Crossing 0~98% | Zero-Crossing 0~98% |
| PCB power source | 10~30VDC | 10~30VDC |
| Input signal | Select one among 4~20mA / 0~10VDC / SSR | Select one among 4~20mA / 0~10VDC / SSR |
| Output | NPN Open collector 2CH (Vc 〈 30V, Ic ≤ 50mA) | NPN Open collector 2CH (Vc 〈 30V, Ic ≤ 50mA) |
| Control Method | Zero-Crossing control with compensation algorithm | Zero-Crossing control with compensation algorithm |
| Cooling | 10A, 25A, 40A : Natural cooling / 40A Cooing fan (Option) |
25A : Natural cooling (Cooling fan - Option) / 40A, 55A, 70A : Cooling fan installed |
| Alarm | Over Current, Over Temperature of heatsink(60℃, 80℃), Load Failure, SCR failure |
Over Current, Over Temperature of heatsink(60℃, 80℃), Load Failure, SCR failure, Unbalanced Load |
| Ambient Temp. | 0 ~ 40℃ | 0 ~ 40℃ |
| Humidity | 40% ~ 85% RH (No condensation) | 40% ~ 85% RH (No condensation) |
| Display | One three color LED | One three color LED, Three single color LED’s |
| NET WT. | 10A, 25A : 287g / 40A(Without fan) : 431g / 40A(With fan) : 454g |
25A : 970g(Without fan) / 40A, 55A, 70A : 1.4Kgs (With fan) |
| Installation | Bolt or DIN-rail | Bolt |
Detailed specification sheets are shown in the product images.
Mini Power Regulator
Mini Power Regulator: overview and buying guide
The Mini Power Regulator is made by PARA ENT and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Mini Power Regulator cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Mini Power Regulator to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine PARA ENT product?
We purchase directly from PARA ENT or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
- The smallest digital power regulator :
26mm width - Single phase / 115mm width – three phase
- Suitable for replacing SSR which has no protecting device. SCR module equipped in Mini is far more durable and reliable than TRIAC in SSR.
- Improved safety through alarming SCR failure which SSR can not detect
- Stable, Reliable and Convenient
Features
Comparison between Mini and SSR
| Content | Mini | SSR | Remark |
|---|---|---|---|
| Load failure alarm | Basically installed | Should attach additional C/T outside or load failure detector | Mini has own C/T inside |
| Over current alarm | Basically installed | None | Output current is more than 100% of its rated current |
| Over temperature alarm | 60℃ Warning, 80℃ Alarm | Mechanical contact | |
| Power module failure alarm | Basically installed | None | |
| Input signal | Select one among 4~20mA / 0~10VDC / SSR | SSR | Select on ordering |
| Alarm point | Basically 2points (Warning 1, Alarm 1) | None | |
| Display | One three color LED displaying operation status and alarm | LED displaying operation status | |
| PCB Power | 10~30VDC | None |
Stability, reliability and convenience
- When power module is failed, electric power to heater is not controlled at full power, which can cause a fire.
- Thus, to detect power module failure is very important to safety directly. Mini equipped with its own CT and CPU secures safety. This is different from SSR which can not detect power module failure.
- In case of SSR, additional device as CT or load failure detector should be attached to detect load failure. But Mini has its own CT, so no need to install any other device which can save labor cost and remove unnecessary wiring job. Eventually, it maximizes convenience.
- Control accuracy is enhanced with compensation algorithm.
- Long period of experience in digital power regulator allows Mini to satisfy stability and reliability.
Ordering Code
| ① NO. of phase | PS : Mini single phase TS : Mini three phase |
| ② Rated current | Single phase 010 : 10A / 025 : 25A / 040 : 40A Three phase 025 : 25A / 040 : 40A / 055 : 55A / 070 : 70A |
| ③ Input signal | I : 4~20mA / V : 0~10VDC / S : SSR |
| ④ Cooling fan | Single phase NONE : Without cooling fan (Cooling fan can not be attached on 10A and 25A) FN : With cooling fan (Only on 40A) Three phase NONE : Without cooling fan FN : With cooling fan (40A, 55A & 70A Cooling fan is basically installed) |
Specification
| Model | Mini (Single phase) | Mini (Three phase) |
|---|---|---|
| Rated voltage | 50~500VAC | 50~500VAC |
| Rated current | 10A / 25A / 40A | 25A / 40A / 55A/ 70A |
| Frequency | 50/60Hz (Auto selectable) | 50/60Hz (Auto selectable) |
| Minimum load | 1A | 1A |
| Output range | Zero-Crossing 0~98% | Zero-Crossing 0~98% |
| PCB power source | 10~30VDC | 10~30VDC |
| Input signal | Select one among 4~20mA / 0~10VDC / SSR | Select one among 4~20mA / 0~10VDC / SSR |
| Output | NPN Open collector 2CH (Vc 〈 30V, Ic ≤ 50mA) | NPN Open collector 2CH (Vc 〈 30V, Ic ≤ 50mA) |
| Control Method | Zero-Crossing control with compensation algorithm | Zero-Crossing control with compensation algorithm |
| Cooling | 10A, 25A, 40A : Natural cooling / 40A Cooing fan (Option) |
25A : Natural cooling (Cooling fan - Option) / 40A, 55A, 70A : Cooling fan installed |
| Alarm | Over Current, Over Temperature of heatsink(60℃, 80℃), Load Failure, SCR failure |
Over Current, Over Temperature of heatsink(60℃, 80℃), Load Failure, SCR failure, Unbalanced Load |
| Ambient Temp. | 0 ~ 40℃ | 0 ~ 40℃ |
| Humidity | 40% ~ 85% RH (No condensation) | 40% ~ 85% RH (No condensation) |
| Display | One three color LED | One three color LED, Three single color LED’s |
| NET WT. | 10A, 25A : 287g / 40A(Without fan) : 431g / 40A(With fan) : 454g |
25A : 970g(Without fan) / 40A, 55A, 70A : 1.4Kgs (With fan) |
| Installation | Bolt or DIN-rail | Bolt |
Detailed specification sheets are shown in the product images.