Measurement GIMAC-IV
New

Measurement GIMAC-IV

GIMAC-IV

Premium multifunction digital integrated metering and control device - 20x4 LCD type.

Features

Measurement Function

ㆍHigh precision measurement of various measurement elements (27 elements)

ㆍExtended power quality measurement (63th, THD)

ㆍEvent recording (300 samples)

ㆍSelect Before & Check Before Operating (CBO) functions

ㆍImproved precision through a digital filter

ㆍAnalog input (2 points, optional)

ㆍCapacitor bank (8 banks)

ㆍOptimal power factor control

ㆍEfficient maximum demand power management

ㆍAutomatic Power Factor Control (APFC), (optional)

Convenience Function

ㆍVarious self-diagnosis functions

Communication Function

ㆍVarious communication functions (1 ports)

Measurement

Model Measurement Display range Accuracy Remarks
GIMAC-415 Current, I 0.000A ~ 999.99kA ±0.2% Ia, Ib, Ic, In
Voltage, V 0.000V ~ 999.99kV ±0.2% Va, Vb, Vc, Vab, Vbc, Vca
Active power, Watts 0.000W ~ 99999.9MW ±0.5% + : Forward
- : Reverse
Reactive power, Var 0.000Var ~ 99999.9MVar ±0.5%
Apparent power, VA 0.000VA ~ 99999.9MVA ±0.5%
Active energy, Wh 0.000Wh ~ 99999.9MWh ±0.5%
Reactive energy, Varh 0.000Varh ~ 99999.9MVarh ±0.5%  
Frequency, F 45 ~ 70Hz ±0.05Hz  
Power factor, PF -1.000 ~ 1.000 ±0.5% cosø (+ : Lag, - : Lead)
Phase 0.000。~ 360.00。 ±0.5。  
Normal current, I1 0.000A ~ 999.99kA    
Reverse phase current, I2 0.000A ~ 999.99kA    
Zero phase voltage, Vo 0.000V ~ 999.99kV ±0.5% Vo, Vo_max
Normal voltage, V1 0.000V ~ 999.99kV    
Reverse phase voltage, V2 0.000V ~ 999.99kV    
Unbalanced factor 0.000 ~ 100.00%    
Harmonics I 0.000A ~ 999.99kA   2nd ~63th
Harmonics V 0.000V ~ 999.99kV   2nd ~63th
Demand I 0.000A ~ 999.99kA   Peak demand
Demand W 0.000W ~ 99999.9MW   Peak demand
AI (Analog Input) DC 4.000 ~ 20.00mA ±0.5%  

Specification

Type Specification
Wirings  1P2W, 1P3W, 3P3W, 3P4W
Input Frequency  50Hz/60Hz
Voltage PT  10~230V
GPT  2.2~230V
Current CT  0.05~6A
Control Voltage   AC/DC 110V or AC/DC 220V
Power Consumption  Max. 30W
Burden PT  Max. 1.0VA
CT  Max. 1.0VA
Input contact 10EA   Digital Input : AC/DC 110V or AC/DC 220V
Output contact 2EA for power  AC 250V 16A/DC 30V 16A
 3840VA/480W
8EA for alarm  AC 250V 16A/DC 30V 16A
 3840VA/480W
Insulation Resistance  Over DC 500V 100㏁
Insulation Voltage   AC 2kV (1kV) / for 1 min
Impulse Voltage   AC 5kV (3kV) Over 1.2×50㎲
Overload Withstand Current circuit  1.2 In for 3 hours
 8 In for 2 seconds
Voltage circuit  1.15 Vn for 3 hours
Fast Transient/Burst Immunity   Power Input 4kV (PT, CT)
 Other Input 2kV (Analog Input 1kV)
ESD (Electrostatic Discharge)   Air 8kV
 Contact 6kV
Operation temperature   -10℃ ~ 55℃
Storage Temperature   -25℃ ~ 70℃
Humidity   Within 80% RH, no condensation
Altitude   2000m and below
Others   Non-impact place
 Non-air pollution place
Standard  IEC 60255, IEC61000-4, KEMC 1110
Communication  MODBUS/RS485, DNP3.0
Dimension (W×H×D)  190×255×116 (mm)
Weight  3.6kg

Catalogues

Error product group when enable variant picker

Availability: In stock
Categories: Electronic
Measurement GIMAC-IV

Measurement GIMAC-IV

$0.00

Measurement GIMAC-IV: overview and buying guide

The Measurement GIMAC-IV (model GIMAC-IV) is made by LS ELECTRIC and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Measurement GIMAC-IV cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Measurement GIMAC-IV to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine LS ELECTRIC product?

We purchase directly from LS ELECTRIC or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

GIMAC-IV

Premium multifunction digital integrated metering and control device - 20x4 LCD type.

Features

Measurement Function

ㆍHigh precision measurement of various measurement elements (27 elements)

ㆍExtended power quality measurement (63th, THD)

ㆍEvent recording (300 samples)

ㆍSelect Before & Check Before Operating (CBO) functions

ㆍImproved precision through a digital filter

ㆍAnalog input (2 points, optional)

ㆍCapacitor bank (8 banks)

ㆍOptimal power factor control

ㆍEfficient maximum demand power management

ㆍAutomatic Power Factor Control (APFC), (optional)

Convenience Function

ㆍVarious self-diagnosis functions

Communication Function

ㆍVarious communication functions (1 ports)

Measurement

Model Measurement Display range Accuracy Remarks
GIMAC-415 Current, I 0.000A ~ 999.99kA ±0.2% Ia, Ib, Ic, In
Voltage, V 0.000V ~ 999.99kV ±0.2% Va, Vb, Vc, Vab, Vbc, Vca
Active power, Watts 0.000W ~ 99999.9MW ±0.5% + : Forward
- : Reverse
Reactive power, Var 0.000Var ~ 99999.9MVar ±0.5%
Apparent power, VA 0.000VA ~ 99999.9MVA ±0.5%
Active energy, Wh 0.000Wh ~ 99999.9MWh ±0.5%
Reactive energy, Varh 0.000Varh ~ 99999.9MVarh ±0.5%  
Frequency, F 45 ~ 70Hz ±0.05Hz  
Power factor, PF -1.000 ~ 1.000 ±0.5% cosø (+ : Lag, - : Lead)
Phase 0.000。~ 360.00。 ±0.5。  
Normal current, I1 0.000A ~ 999.99kA    
Reverse phase current, I2 0.000A ~ 999.99kA    
Zero phase voltage, Vo 0.000V ~ 999.99kV ±0.5% Vo, Vo_max
Normal voltage, V1 0.000V ~ 999.99kV    
Reverse phase voltage, V2 0.000V ~ 999.99kV    
Unbalanced factor 0.000 ~ 100.00%    
Harmonics I 0.000A ~ 999.99kA   2nd ~63th
Harmonics V 0.000V ~ 999.99kV   2nd ~63th
Demand I 0.000A ~ 999.99kA   Peak demand
Demand W 0.000W ~ 99999.9MW   Peak demand
AI (Analog Input) DC 4.000 ~ 20.00mA ±0.5%  

Specification

Type Specification
Wirings  1P2W, 1P3W, 3P3W, 3P4W
Input Frequency  50Hz/60Hz
Voltage PT  10~230V
GPT  2.2~230V
Current CT  0.05~6A
Control Voltage   AC/DC 110V or AC/DC 220V
Power Consumption  Max. 30W
Burden PT  Max. 1.0VA
CT  Max. 1.0VA
Input contact 10EA   Digital Input : AC/DC 110V or AC/DC 220V
Output contact 2EA for power  AC 250V 16A/DC 30V 16A
 3840VA/480W
8EA for alarm  AC 250V 16A/DC 30V 16A
 3840VA/480W
Insulation Resistance  Over DC 500V 100㏁
Insulation Voltage   AC 2kV (1kV) / for 1 min
Impulse Voltage   AC 5kV (3kV) Over 1.2×50㎲
Overload Withstand Current circuit  1.2 In for 3 hours
 8 In for 2 seconds
Voltage circuit  1.15 Vn for 3 hours
Fast Transient/Burst Immunity   Power Input 4kV (PT, CT)
 Other Input 2kV (Analog Input 1kV)
ESD (Electrostatic Discharge)   Air 8kV
 Contact 6kV
Operation temperature   -10℃ ~ 55℃
Storage Temperature   -25℃ ~ 70℃
Humidity   Within 80% RH, no condensation
Altitude   2000m and below
Others   Non-impact place
 Non-air pollution place
Standard  IEC 60255, IEC61000-4, KEMC 1110
Communication  MODBUS/RS485, DNP3.0
Dimension (W×H×D)  190×255×116 (mm)
Weight  3.6kg

Catalogues