Premium multifunction digital integrated metering and control device - Color graphic Touch LCD type.

Features

Measurement Function

ㆍHigh precision measurement of various measurement elements (35 elements)

ㆍExtended power quality measurement (63th, THD, TDD, K-factor, Crest factor)

ㆍEvent recording (20~1024 samples)

ㆍSelect Before Operating (SBO) Function

ㆍAutomatic Power Factor Control (APFC) (optional)

ㆍTransient wave and event measurement

Convenience Function

ㆍColor touch graphic LCD

ㆍLanguage and user selection menu

ㆍManager software for PC connection

ㆍStatistics and trends for measurement elements

ㆍAdd-ons

Communication Function

ㆍVarious communication functions (3 ports)

Measurement

Type Measuring item Datiled measuring item Accuracy
Voltage (V) Line voltage Vab, Vbc, Vca, Vlavg Note 0.2%
Phase voltage Va, Vb, Vc, Vnavg 0.2%
Normal, reversed-phase voltage V1, V2 -
Crest Factor Vab, Vbc, Vca, Va, Vb, Vc -
Current Phase current Ia, Ib, Ic, Iavg 0.2%
XPhase current Ix 0.2%
Normal, reversed-phase currents I1, I2 -
Crest Factor Ia, Ib, Ic -
Phase Line voltage ∠Vab, ∠Vbc, ∠Vca 0.5°
Phase voltage ∠Va, ∠Vb, ∠Vc 0.5°
Phase current ∠Ia, ∠Ib, ∠Ic, ∠Ix 0.5°
Electricity Active power Pa, Pb, Pc, ΣP 0.5class
Reactive power Qa, Qb, Qc, ΣQ 0.5class
Apparent power Sa, Sb, Sc, ΣS 0.5class
Electricity energy Active energy WHa, WHb, WHc, ΣWH 0.5class
Reactive energy VARHa, VARHb, VARHc, ΣVARH 0.5class
Reverse active energy rWHa, rWHb, rWHc, ΣrWH 0.5class
Reverse reactive energy rVARHa, rVARHb, rVARHc, ΣrVARH 0.5class
Apparent energy VAHa, VAHb, VAHc, ΣVAH 0.5class
freq Frequency F(Hz) 0.1%
Power Factor Power Factor(PF) Power Factor Power Factor(PF) PFa, PFb, PFc, ΣPF phase phase accuracy
1st harmonic power factor (DPF) DPFa, DPFb, DPFc, ΣDPF
Harmonics Line voltage Vab, Vbc, Vca 2~63th Harmonics -
Phase voltage Va, Vb, Vc 2~63th Harmonics  
Phase current Ia, Ib, Ic 2~63th Harmonics -
THD Vab, Vbc, Vca, Va, Vb, Vc, Ia, Ib, Ic  
TDD Ia, Ib, Ic  
K-FACTOR Ia, Ib, Ic  
AI 4~20mA AI01, AI02 0.5%

Note : Average of line voltage

APEC

Type APEC
BANK setting BANK number 0-8
Alarm number 0-1
Capacitor capacitance setting None ~ 999MVA
Alarm contact setting Setting one of extra contact out of DO_01~DO_08
Capacitor closing delay time 10~300sec / 1sec
Dead time (time for charge or discharge) 10~300sec / 1sec
Maximum power factor setting 0.95~1~ -0.90 ( - : indicating lead phase)
Minimum power factor setting 0.80 ~ 0.95
Alarm power factor setting (Alarm occurred) 0.00 ~ 0.90
Event occurrence
Under Voltage
and control Over PF
Low Current Set whether to get EVENT occurred or set the control in case the average current of 3 phase is 1A
Under Voltage Set whether to get EVENT occurred or set the control in case phase voltage ( 3 phase 3 wire, open delta, line voltage)
Over PF Set whether to get EVENT occurred or not when over Max. PF
Under PF Set whether to get EVENT occurred or not when over Min. PF
Over Volt THD Set whether to get EVENT occurred and BANK control or not when THD is above the setpoint
Power Factor control Automatic control Auto
Manual control Manual
Combination control In case all capacitances are set
Circulation control Capacitor In case capacitances are not set - Opening the closed one first and closing the opened last

Specification

※ Avoid places with vibration, shock, dust, moisture, corrosive, gas, etc.

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
Categories: Electronic
Measurement GIMAC-V

Measurement GIMAC-V

$0.00

Measurement GIMAC-V: overview and buying guide

The Measurement GIMAC-V (model GIMAC-V) is made by LS ELECTRIC and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Measurement GIMAC-V cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Measurement GIMAC-V to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine LS ELECTRIC product?

We purchase directly from LS ELECTRIC or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

GIMAC-V

Premium multifunction digital integrated metering and control device - Color graphic Touch LCD type.

Features

Measurement Function

ㆍHigh precision measurement of various measurement elements (35 elements)

ㆍExtended power quality measurement (63th, THD, TDD, K-factor, Crest factor)

ㆍEvent recording (20~1024 samples)

ㆍSelect Before Operating (SBO) Function

ㆍAutomatic Power Factor Control (APFC) (optional)

ㆍTransient wave and event measurement

Convenience Function

ㆍColor touch graphic LCD

ㆍLanguage and user selection menu

ㆍManager software for PC connection

ㆍStatistics and trends for measurement elements

ㆍAdd-ons

Communication Function

ㆍVarious communication functions (3 ports)

Measurement

Type Measuring item Datiled measuring item Accuracy
Voltage (V) Line voltage Vab, Vbc, Vca, Vlavg Note 0.2%
Phase voltage Va, Vb, Vc, Vnavg 0.2%
Normal, reversed-phase voltage V1, V2 -
Crest Factor Vab, Vbc, Vca, Va, Vb, Vc -
Current Phase current Ia, Ib, Ic, Iavg 0.2%
XPhase current Ix 0.2%
Normal, reversed-phase currents I1, I2 -
Crest Factor Ia, Ib, Ic -
Phase Line voltage ∠Vab, ∠Vbc, ∠Vca 0.5°
Phase voltage ∠Va, ∠Vb, ∠Vc 0.5°
Phase current ∠Ia, ∠Ib, ∠Ic, ∠Ix 0.5°
Electricity Active power Pa, Pb, Pc, ΣP 0.5class
Reactive power Qa, Qb, Qc, ΣQ 0.5class
Apparent power Sa, Sb, Sc, ΣS 0.5class
Electricity energy Active energy WHa, WHb, WHc, ΣWH 0.5class
Reactive energy VARHa, VARHb, VARHc, ΣVARH 0.5class
Reverse active energy rWHa, rWHb, rWHc, ΣrWH 0.5class
Reverse reactive energy rVARHa, rVARHb, rVARHc, ΣrVARH 0.5class
Apparent energy VAHa, VAHb, VAHc, ΣVAH 0.5class
freq Frequency F(Hz) 0.1%
Power Factor Power Factor(PF) Power Factor Power Factor(PF) PFa, PFb, PFc, ΣPF phase phase accuracy
1st harmonic power factor (DPF) DPFa, DPFb, DPFc, ΣDPF
Harmonics Line voltage Vab, Vbc, Vca 2~63th Harmonics -
Phase voltage Va, Vb, Vc 2~63th Harmonics  
Phase current Ia, Ib, Ic 2~63th Harmonics -
THD Vab, Vbc, Vca, Va, Vb, Vc, Ia, Ib, Ic  
TDD Ia, Ib, Ic  
K-FACTOR Ia, Ib, Ic  
AI 4~20mA AI01, AI02 0.5%

Note : Average of line voltage

APEC

Type APEC
BANK setting BANK number 0-8
Alarm number 0-1
Capacitor capacitance setting None ~ 999MVA
Alarm contact setting Setting one of extra contact out of DO_01~DO_08
Capacitor closing delay time 10~300sec / 1sec
Dead time (time for charge or discharge) 10~300sec / 1sec
Maximum power factor setting 0.95~1~ -0.90 ( - : indicating lead phase)
Minimum power factor setting 0.80 ~ 0.95
Alarm power factor setting (Alarm occurred) 0.00 ~ 0.90
Event occurrence
Under Voltage
and control Over PF
Low Current Set whether to get EVENT occurred or set the control in case the average current of 3 phase is 1A
Under Voltage Set whether to get EVENT occurred or set the control in case phase voltage ( 3 phase 3 wire, open delta, line voltage)
Over PF Set whether to get EVENT occurred or not when over Max. PF
Under PF Set whether to get EVENT occurred or not when over Min. PF
Over Volt THD Set whether to get EVENT occurred and BANK control or not when THD is above the setpoint
Power Factor control Automatic control Auto
Manual control Manual
Combination control In case all capacitances are set
Circulation control Capacitor In case capacitances are not set - Opening the closed one first and closing the opened last

Specification

※ Avoid places with vibration, shock, dust, moisture, corrosive, gas, etc.

Detailed specification sheets are shown in the product images.

Catalogues