{"product_id":"low-voltage-vfd-panel-133149","title":"Low Voltage VFD Panel","description":"\u003cp\u003e\u003cstrong\u003eLow Voltage VFD Panel\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eLS ELECTRIC Low Voltage VFD panel provides customers with optimized drive solutions for motor control and energy saving.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e- Easy to use \u0026amp; easy maintenance design\u003c\/p\u003e \u003cp\u003e- Built-in AC reactor for harmonic reduction\u003c\/p\u003e \u003cp\u003e- Built-in standard sequence meets all operating conditions\u003c\/p\u003e \u003cp\u003e- Vector system, high capacity \u0026amp; energy saving\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e \u003ch3\u003eHVAC Compact Solution\u003c\/h3\u003e\u003cp\u003eLS HVAC compact drive panel offers not only optimized compact design but also additional filter option based on customer needs.\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003ePanel Configuration\u003c\/strong\u003e - Standard design (Built-in DOL bypass) - Applicable customized design (Additional filter, etc.) \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eApplicable Drive \u0026amp; Option\u003c\/strong\u003e - H100 series - Built-in DOL (Y-△ option)\\ - Applicable various operation mode (Remote\/Panel) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eCustomer Optimized Solution\u003c\/strong\u003e - Wall mountable design for building HVAC system - Short lead time with standard design in local factory (Korea, Vietnam) \u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003ch3\u003eHVAC Premium Solution\u003c\/h3\u003e\u003cp\u003eLS HVAC premium drive panel offers optimized customer solution with LS PLC\/ HMI in demand for control \u0026amp; monitoring.\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003ePanel Configuration\u003c\/strong\u003e - Standard design (Built-in DOL bypass) - Built-in LS HMI - Built-in LS PLC for customizing \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eApplicable Drive \u0026amp; Option\u003c\/strong\u003e - H100 series - Built-in DOL (Y-△ option) - Various operation information on HMI \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eCustomer Optimized Solution\u003c\/strong\u003e - Wall mountable design for building HVAC system - Customizing solution with PLC for various field condition - Short lead time with standard design in local factory (Korea, Vietnam) \u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003ch3\u003eLS Optimized Solution\u003c\/h3\u003e\u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003eBuilt-in LS PLC (XBM)\u003c\/strong\u003e - XBM main unit + XGT analog I\/O module (Applicable additional module) - PLC wiring with XTB-40J terminal \u003cstrong\u003eSpecification\u003c\/strong\u003e - Main unit I\/O points: Input 16 \/ Output 14 - HVAC drive panel use 10 points input and 8 points output ㆍInput: Additional 6 points possible ㆍOutput: Additional 6 points possible\u003cbr\u003e 2 points for high-speed counter (Disable) \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eBuilt-in LS HMI (eXP60)\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e- 10.2” TFT LCD-applied wide type\u003c\/p\u003e \u003cp\u003e- LED backlight adopted for enhanced contrast ratio and low-power\u003c\/p\u003e \u003cp\u003e- Wide variety of communication interfaces\u003cbr\u003e ㆍSerial: 2 channel RS232C\/RS485, 1 channel RS422\/485 combination\u003cbr\u003e ㆍEthernet: 1 channel 10\/100Base-TX\u003c\/p\u003e \u003cp\u003e- Large memory for drawing (64MB)\u003c\/p\u003e \u003cp\u003e- RTC function (Maintained by battery)\u003c\/p\u003e \u003cp\u003e- Convenient downloading\/Uploading of drawings via USB port in the front\u003c\/p\u003e \u003cp\u003e- IP65 enclosure\u003c\/p\u003e \u003cp\u003e- Certificates: CE, UL, KC\u003c\/p\u003e \u003ch3\u003eCustomer Optimized Solution\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eHMI Configurations \u0026amp; Features\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e- Operation information \u0026amp; monitoring\u003c\/p\u003e \u003cp\u003e- Operation control with HMI (Without keypad)\u003c\/p\u003e \u003cp\u003e- Parameter check \u0026amp; setting\u003c\/p\u003e \u003cp\u003e- History check\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003e1. Monitoring\u003c\/strong\u003e • Operation information • Operation status • Operation mode \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003e2. Operation Control\u003c\/strong\u003e • Frequency, Acc.\/Dec. time setting • Drive status control • Mode selection \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003e3. Parameter Setting\u003c\/strong\u003e • Parameter read • Parameter write • PLC DI\/DO status check \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003e4. History Check\u003c\/strong\u003e • Drive \u0026amp; event log (Run\/Stop\/Trip\/etc.) - Yellow shadow: Recovery record - White shadow: Current status • USB back-up \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003ch3\u003ePlant Solution\u003c\/h3\u003e\u003cp\u003eLS Plant drive panel offers optimized motor control and energy saving solution in various factories.\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cstrong\u003ePanel Configuration\u003c\/strong\u003e - Standard design (Built-in DOL bypass) - LS PI applied on door control \u003c\/td\u003e \u003ctd\u003e \u003cstrong\u003eApplicable Drive \u0026amp; Option\u003c\/strong\u003e - iS7, H100 series - Y-△ \/ Reactor \/ Soft starter starting option \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003e \u003cstrong\u003eCustomer Optimized Solution\u003c\/strong\u003e - Customized design\u003cbr\u003e dv\/dt filter, sine wave filter, flame retardant cable (XHHW), Draw-out type panel, harmonic filter, etc. - MCC-drive package solution\u003cbr\u003e Power busbar connection between MCC and drive panel \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eDrive Panel Specifications\u003c\/h3\u003e\u003cp\u003e* Based on the standard specifications\u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eItem\u003c\/th\u003e \u003cth\u003eFor Plant\u003c\/th\u003e \u003cth\u003eFor HVAC\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eBypass Line\u003c\/th\u003e \u003ctd\u003eStandard: DOL\u003cbr\u003eOption: Y-△, reactor, soft starter\u003c\/td\u003e \u003ctd\u003eStandard: DOL\u003cbr\u003eOption: Y-△\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eHarmonic Filter\u003c\/th\u003e \u003ctd\u003eAC Reactor, DC reactor (Built-in iS7 up to 220kW)\u003cbr\u003eOption: Passive filter (≤ THD 5%)\u003c\/td\u003e \u003ctd\u003eAC reactor, DC reactor (Built-in H100 37~500kW)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eNoise Filter\u003c\/th\u003e \u003ctd\u003eEMI filter built-in iS7 (up to 22kW)\u003c\/td\u003e \u003ctd\u003eEMI filter built-in H100\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOutput Filter\u003c\/th\u003e \u003ctd\u003eUnder 500M: dv\/dt filter\u003cbr\u003eOver 500M: Sine wave filter\u003c\/td\u003e \u003ctd\u003e- (Under 50M)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eShape\u003c\/th\u003e \u003ctd\u003eStandard: 1 drive \/ 1 panel\u003cbr\u003eOption: Others\u003c\/td\u003e \u003ctd\u003eStandard: 1 drive \/ 1 panel\u003cbr\u003eOption: others\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eColor\u003c\/th\u003e \u003ctd\u003eCustomized\u003c\/td\u003e \u003ctd\u003eCustomized\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eStructure\u003c\/th\u003e \u003ctd\u003eIndoor stand alone (Front\/Rear open)\u003c\/td\u003e \u003ctd\u003eIndoor stand alone (Front open)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eThickness\u003c\/th\u003e \u003ctd\u003eFrame: 2.3t, Door: 2.3t (Option: 3.2t)\u003c\/td\u003e \u003ctd\u003eFrame: 2.3t, Door: 2.3t\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCable In\/Out\u003c\/th\u003e \u003ctd\u003eBottom\/Bottom\u003c\/td\u003e \u003ctd\u003eBottom\/Bottom\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCooling Method\u003c\/th\u003e \u003ctd\u003eForced air cooling\u003c\/td\u003e \u003ctd\u003eNatural cooling, forced air cooling\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOperation Method\u003c\/th\u003e \u003ctd\u003ePanel, local, DCS\u003c\/td\u003e \u003ctd\u003ePanel, remote\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSpeed Reference\u003c\/th\u003e \u003ctd\u003eManual, auto\u003c\/td\u003e \u003ctd\u003eManual, auto\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eStarting Method\u003c\/th\u003e \u003ctd\u003eDrive, bypass\u003c\/td\u003e \u003ctd\u003eDrive, bypass\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003ePanel Operation\u003c\/th\u003e \u003ctd\u003eRun, stop, reset\u003c\/td\u003e \u003ctd\u003eRun, stop, reset\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eIndicating Lamp\u003c\/th\u003e \u003ctd\u003eRun, stop, trip\u003c\/td\u003e \u003ctd\u003eRun, stop, trip\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eEnclosure\u003c\/th\u003e \u003ctd\u003eIP21, IP42 (Option)\u003c\/td\u003e \u003ctd\u003eIP21\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003eNote) Cable I\/O, paint film, color and so forth may change upon customers’ request.\u003c\/p\u003e\u003ch3\u003eModel \u0026amp; Type\u003c\/h3\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-7da964de784635ac.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-LS ELECTRIC-Low Voltage VFD Panel-Factory Automation Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-9961eaa2bc2dc9ed.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-LS ELECTRIC-Low Voltage VFD Panel\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LS ELECTRIC","offers":[{"title":"Default Title","offer_id":58447235907924,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/8c7b4265-4881-4bee-8d22-35b12b9e407f.jpg?v=1795192782","url":"https:\/\/premiumemart.com\/products\/low-voltage-vfd-panel-133149","provider":"Premium Emart","version":"1.0","type":"link"}