Low Voltage VFD Panel
LS ELECTRIC Low Voltage VFD panel provides customers with optimized drive solutions for motor control and energy saving.
Features
- Easy to use & easy maintenance design
- Built-in AC reactor for harmonic reduction
- Built-in standard sequence meets all operating conditions
- Vector system, high capacity & energy saving
Specifications
HVAC Compact Solution
LS HVAC compact drive panel offers not only optimized compact design but also additional filter option based on customer needs.
| Panel Configuration - Standard design (Built-in DOL bypass) - Applicable customized design (Additional filter, etc.) | Applicable Drive & Option - H100 series - Built-in DOL (Y-△ option)\ - Applicable various operation mode (Remote/Panel) |
| Customer Optimized Solution - Wall mountable design for building HVAC system - Short lead time with standard design in local factory (Korea, Vietnam) |
HVAC Premium Solution
LS HVAC premium drive panel offers optimized customer solution with LS PLC/ HMI in demand for control & monitoring.
| Panel Configuration - Standard design (Built-in DOL bypass) - Built-in LS HMI - Built-in LS PLC for customizing | Applicable Drive & Option - H100 series - Built-in DOL (Y-△ option) - Various operation information on HMI |
| Customer Optimized Solution - Wall mountable design for building HVAC system - Customizing solution with PLC for various field condition - Short lead time with standard design in local factory (Korea, Vietnam) |
LS Optimized Solution
| Built-in LS PLC (XBM) - XBM main unit + XGT analog I/O module (Applicable additional module) - PLC wiring with XTB-40J terminal Specification - Main unit I/O points: Input 16 / Output 14 - HVAC drive panel use 10 points input and 8 points output ㆍInput: Additional 6 points possible ㆍOutput: Additional 6 points possible 2 points for high-speed counter (Disable) |
Built-in LS HMI (eXP60)
Specification
- 10.2” TFT LCD-applied wide type
- LED backlight adopted for enhanced contrast ratio and low-power
- Wide variety of communication interfaces
ㆍSerial: 2 channel RS232C/RS485, 1 channel RS422/485 combination
ㆍEthernet: 1 channel 10/100Base-TX
- Large memory for drawing (64MB)
- RTC function (Maintained by battery)
- Convenient downloading/Uploading of drawings via USB port in the front
- IP65 enclosure
- Certificates: CE, UL, KC
Customer Optimized Solution
HMI Configurations & Features
- Operation information & monitoring
- Operation control with HMI (Without keypad)
- Parameter check & setting
- History check
| 1. Monitoring • Operation information • Operation status • Operation mode | |
| 2. Operation Control • Frequency, Acc./Dec. time setting • Drive status control • Mode selection | |
| 3. Parameter Setting • Parameter read • Parameter write • PLC DI/DO status check | |
| 4. History Check • Drive & event log (Run/Stop/Trip/etc.) - Yellow shadow: Recovery record - White shadow: Current status • USB back-up |
Plant Solution
LS Plant drive panel offers optimized motor control and energy saving solution in various factories.
| Panel Configuration - Standard design (Built-in DOL bypass) - LS PI applied on door control | Applicable Drive & Option - iS7, H100 series - Y-△ / Reactor / Soft starter starting option |
| Customer Optimized Solution - Customized design dv/dt filter, sine wave filter, flame retardant cable (XHHW), Draw-out type panel, harmonic filter, etc. - MCC-drive package solution Power busbar connection between MCC and drive panel | |
Drive Panel Specifications
* Based on the standard specifications
| Item | For Plant | For HVAC |
|---|---|---|
| Bypass Line | Standard: DOL Option: Y-△, reactor, soft starter | Standard: DOL Option: Y-△ |
| Harmonic Filter | AC Reactor, DC reactor (Built-in iS7 up to 220kW) Option: Passive filter (≤ THD 5%) | AC reactor, DC reactor (Built-in H100 37~500kW) |
| Noise Filter | EMI filter built-in iS7 (up to 22kW) | EMI filter built-in H100 |
| Output Filter | Under 500M: dv/dt filter Over 500M: Sine wave filter | - (Under 50M) |
| Shape | Standard: 1 drive / 1 panel Option: Others | Standard: 1 drive / 1 panel Option: others |
| Color | Customized | Customized |
| Structure | Indoor stand alone (Front/Rear open) | Indoor stand alone (Front open) |
| Thickness | Frame: 2.3t, Door: 2.3t (Option: 3.2t) | Frame: 2.3t, Door: 2.3t |
| Cable In/Out | Bottom/Bottom | Bottom/Bottom |
| Cooling Method | Forced air cooling | Natural cooling, forced air cooling |
| Operation Method | Panel, local, DCS | Panel, remote |
| Speed Reference | Manual, auto | Manual, auto |
| Starting Method | Drive, bypass | Drive, bypass |
| Panel Operation | Run, stop, reset | Run, stop, reset |
| Indicating Lamp | Run, stop, trip | Run, stop, trip |
| Enclosure | IP21, IP42 (Option) | IP21 |
Note) Cable I/O, paint film, color and so forth may change upon customers’ request.
Model & Type
Detailed specification sheets are shown in the product images.
Catalogues
Low Voltage VFD Panel
Low Voltage VFD Panel: overview and buying guide
The Low Voltage VFD Panel is made by LS ELECTRIC and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Low Voltage VFD Panel cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Low Voltage VFD Panel to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine LS ELECTRIC product?
We purchase directly from LS ELECTRIC or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Low Voltage VFD Panel
LS ELECTRIC Low Voltage VFD panel provides customers with optimized drive solutions for motor control and energy saving.
Features
- Easy to use & easy maintenance design
- Built-in AC reactor for harmonic reduction
- Built-in standard sequence meets all operating conditions
- Vector system, high capacity & energy saving
Specifications
HVAC Compact Solution
LS HVAC compact drive panel offers not only optimized compact design but also additional filter option based on customer needs.
| Panel Configuration - Standard design (Built-in DOL bypass) - Applicable customized design (Additional filter, etc.) | Applicable Drive & Option - H100 series - Built-in DOL (Y-△ option)\ - Applicable various operation mode (Remote/Panel) |
| Customer Optimized Solution - Wall mountable design for building HVAC system - Short lead time with standard design in local factory (Korea, Vietnam) |
HVAC Premium Solution
LS HVAC premium drive panel offers optimized customer solution with LS PLC/ HMI in demand for control & monitoring.
| Panel Configuration - Standard design (Built-in DOL bypass) - Built-in LS HMI - Built-in LS PLC for customizing | Applicable Drive & Option - H100 series - Built-in DOL (Y-△ option) - Various operation information on HMI |
| Customer Optimized Solution - Wall mountable design for building HVAC system - Customizing solution with PLC for various field condition - Short lead time with standard design in local factory (Korea, Vietnam) |
LS Optimized Solution
| Built-in LS PLC (XBM) - XBM main unit + XGT analog I/O module (Applicable additional module) - PLC wiring with XTB-40J terminal Specification - Main unit I/O points: Input 16 / Output 14 - HVAC drive panel use 10 points input and 8 points output ㆍInput: Additional 6 points possible ㆍOutput: Additional 6 points possible 2 points for high-speed counter (Disable) |
Built-in LS HMI (eXP60)
Specification
- 10.2” TFT LCD-applied wide type
- LED backlight adopted for enhanced contrast ratio and low-power
- Wide variety of communication interfaces
ㆍSerial: 2 channel RS232C/RS485, 1 channel RS422/485 combination
ㆍEthernet: 1 channel 10/100Base-TX
- Large memory for drawing (64MB)
- RTC function (Maintained by battery)
- Convenient downloading/Uploading of drawings via USB port in the front
- IP65 enclosure
- Certificates: CE, UL, KC
Customer Optimized Solution
HMI Configurations & Features
- Operation information & monitoring
- Operation control with HMI (Without keypad)
- Parameter check & setting
- History check
| 1. Monitoring • Operation information • Operation status • Operation mode | |
| 2. Operation Control • Frequency, Acc./Dec. time setting • Drive status control • Mode selection | |
| 3. Parameter Setting • Parameter read • Parameter write • PLC DI/DO status check | |
| 4. History Check • Drive & event log (Run/Stop/Trip/etc.) - Yellow shadow: Recovery record - White shadow: Current status • USB back-up |
Plant Solution
LS Plant drive panel offers optimized motor control and energy saving solution in various factories.
| Panel Configuration - Standard design (Built-in DOL bypass) - LS PI applied on door control | Applicable Drive & Option - iS7, H100 series - Y-△ / Reactor / Soft starter starting option |
| Customer Optimized Solution - Customized design dv/dt filter, sine wave filter, flame retardant cable (XHHW), Draw-out type panel, harmonic filter, etc. - MCC-drive package solution Power busbar connection between MCC and drive panel | |
Drive Panel Specifications
* Based on the standard specifications
| Item | For Plant | For HVAC |
|---|---|---|
| Bypass Line | Standard: DOL Option: Y-△, reactor, soft starter | Standard: DOL Option: Y-△ |
| Harmonic Filter | AC Reactor, DC reactor (Built-in iS7 up to 220kW) Option: Passive filter (≤ THD 5%) | AC reactor, DC reactor (Built-in H100 37~500kW) |
| Noise Filter | EMI filter built-in iS7 (up to 22kW) | EMI filter built-in H100 |
| Output Filter | Under 500M: dv/dt filter Over 500M: Sine wave filter | - (Under 50M) |
| Shape | Standard: 1 drive / 1 panel Option: Others | Standard: 1 drive / 1 panel Option: others |
| Color | Customized | Customized |
| Structure | Indoor stand alone (Front/Rear open) | Indoor stand alone (Front open) |
| Thickness | Frame: 2.3t, Door: 2.3t (Option: 3.2t) | Frame: 2.3t, Door: 2.3t |
| Cable In/Out | Bottom/Bottom | Bottom/Bottom |
| Cooling Method | Forced air cooling | Natural cooling, forced air cooling |
| Operation Method | Panel, local, DCS | Panel, remote |
| Speed Reference | Manual, auto | Manual, auto |
| Starting Method | Drive, bypass | Drive, bypass |
| Panel Operation | Run, stop, reset | Run, stop, reset |
| Indicating Lamp | Run, stop, trip | Run, stop, trip |
| Enclosure | IP21, IP42 (Option) | IP21 |
Note) Cable I/O, paint film, color and so forth may change upon customers’ request.
Model & Type
Detailed specification sheets are shown in the product images.