Low Voltage VFD (General Drive) iG5A
Features
Powerful & Upgraded Performance
| Sensorless Vector Control The built-in sensorless vector control provides superb speed control and powerful torque. | Built-in PID Control The built-in PID function enables control of flow-rate, oil-pressure, temperature, etc without any extra controllers. | ||
| Built-in Dynamic Braking Circuit The built-in dynamic braking circuit minimizes deceleration time via braking resistors. |
User-Friendly Interface & Easy Maintenance
| Easy Change of Fan iG5A is designed to easily change the fan in case of a fan breakdown. | Cooling Fan Control By controlling the cooling fan, iG5A provides a virtually quiet environment according to the status of operation. | ||
| User-Friendly Interface The 4-direction key provides easy handling and monitoring. |
Compact Size
| Global Standard iG5A series complies with CE and UL standards. | PNP/NPN Input Both PNP and NPN inputs become possible and these enable the user to use the outer power. To do so, users will be given a wide range of choices for selecting the controller. |
Frame Design
Type Designation
Specification
1-phase 200V Class
| SV ㅁㅁㅁ iG5A-1ㅁㅁ | 004 | 008 | 015 | |
|---|---|---|---|---|
| Max. Capacity 1) | [HP] | 0.5 | 1 | 2 |
| [kW] | 0.4 | 0.75 | 1.5 | |
| Output Rating | Capacity [kVA] 2) | 0.95 | 1.9 | 3.0 |
| FLA [A] 3) | 2.5 | 5 | 8 | |
| Max Frequency | 400 [Hz] 4) | |||
| Max Voltage | 3 Phase 200 ~ 230V 5) | |||
| Input Rating | Rated Voltage | 1phase 200~230 VAC (+10%, -15%) | ||
| Rated Frequency | 50 ~ 60 [Hz] (±5%) | |||
| Cooling Method | Forced Air Cooling | |||
| Weight [kg] | 0.76 | 1.12 | 1.84 | |
3-phase 200V Class
| SV ㅁㅁㅁ iG5A-2ㅁㅁ | 004 | 008 | 015 | 022 | 037 | 040 | 055 | 075 | 110 | 150 | 185 | 220 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Capacity 1) | [HP] | 0.5 | 1 | 2 | 3 | 5 | 5.4 | 7.5 | 10 | 15 | 20 | 25 | 30 |
| [kW] | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 4.0 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | |
| Output Rating | Capacity [kVA] 2) | 0.95 | 1.9 | 3.0 | 4.5 | 6.1 | 6.5 | 9.1 | 12.2 | 17.5 | 22.9 | 28.2 | 33.5 |
| FLA[A] 3) | 2.5 | 5 | 8 | 12 | 16 | 17 | 24 | 32 | 46 | 60 | 74 | 88 | |
| Max Frequency | 400 [Hz] 4) | ||||||||||||
| Max Voltage | 3 Phase 200 ~ 230V 5) | ||||||||||||
| Input Rating | Rated Voltage | 3 phase 200~230 (+10%, -15%) | |||||||||||
| Rated Frequency | 50~60 [Hz] (±5%) | ||||||||||||
| Cooling Method | N/C 6) | Forced Air Cooling | |||||||||||
| Weight [kg] | 0.76 | 0.77 | 1.12 | 1.84 | 1.89 | 1.89 | 3.66 | 3.66 | 9.0 | 9.0 | 13.3 | 13.3 | |
3-phsae 400V Class
| SV ㅁㅁㅁ iG5A-4ㅁㅁ | 004 | 008 | 015 | 022 | 037 | 040 | 055 | 075 | 110 | 150 | 185 | 220 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Capacity 1) | [HP] | 0.5 | 1 | 2 | 3 | 5 | 5.4 | 7.5 | 10 | 15 | 20 | 25 | 30 |
| [kW] | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 4.0 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | |
| Output Rating | Capacity [kVA] 2) | 0.95 | 1.9 | 3.0 | 4.5 | 6.1 | 6.9 | 9.1 | 12.2 | 18.3 | 22.9 | 29.7 | 34.3 |
| FLA [A] 3) | 1.25 | 2.5 | 4 | 6 | 8 | 9 | 12 | 16 | 24 | 30 | 39 | 45 | |
| Max Frequency | 400 [Hz] 4) | ||||||||||||
| Voltage [V] | 3 Phase 380 ~ 480V 5) | ||||||||||||
| Input Rating | Rated Voltage | 3 phase 380~480 VAC (+10%, -15%) | |||||||||||
| Rated Frequency | 50~60 [Hz] (±5%) | ||||||||||||
| Cooling Method | N/C 6) | Forced Air Cooling | |||||||||||
| Weight [kg] | 0.76 | 0.77 | 1.12 | 1.84 | 1.89 | 1.89 | 3.66 | 3.66 | 9.0 | 9.0 | 13.3 | 13.3 | |
1) Indicates the maximum applicable motor capacity when using the standard 4-pole LS motor.
2) Rated capacity is based on 220V for 200V series and 440V for 400V series.
3) Refer to 15-3 of the user manual when carrier frequency setting (39) is above 3kHz.
4) Max. frequency setting range is extended to 300Hz when H40 (Control mode select) is set to 3 (Sensorless vector control).
5) Max. output voltage cannot be higher than the input voltage. It can be programmable below the input voltage.
6) Self-Cooling
Detailed specification sheets are shown in the product images.
Catalogues
Low Voltage VFD (General Drive) iG5A
Low Voltage VFD (General Drive) iG5A: overview and buying guide
The Low Voltage VFD (General Drive) iG5A (model iG5A) is made by LS ELECTRIC and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Low Voltage VFD (General Drive) iG5A cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Low Voltage VFD (General Drive) iG5A to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine LS ELECTRIC product?
We purchase directly from LS ELECTRIC or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Features
Powerful & Upgraded Performance
| Sensorless Vector Control The built-in sensorless vector control provides superb speed control and powerful torque. | Built-in PID Control The built-in PID function enables control of flow-rate, oil-pressure, temperature, etc without any extra controllers. | ||
| Built-in Dynamic Braking Circuit The built-in dynamic braking circuit minimizes deceleration time via braking resistors. |
User-Friendly Interface & Easy Maintenance
| Easy Change of Fan iG5A is designed to easily change the fan in case of a fan breakdown. | Cooling Fan Control By controlling the cooling fan, iG5A provides a virtually quiet environment according to the status of operation. | ||
| User-Friendly Interface The 4-direction key provides easy handling and monitoring. |
Compact Size
| Global Standard iG5A series complies with CE and UL standards. | PNP/NPN Input Both PNP and NPN inputs become possible and these enable the user to use the outer power. To do so, users will be given a wide range of choices for selecting the controller. |
Frame Design
Type Designation
Specification
1-phase 200V Class
| SV ㅁㅁㅁ iG5A-1ㅁㅁ | 004 | 008 | 015 | |
|---|---|---|---|---|
| Max. Capacity 1) | [HP] | 0.5 | 1 | 2 |
| [kW] | 0.4 | 0.75 | 1.5 | |
| Output Rating | Capacity [kVA] 2) | 0.95 | 1.9 | 3.0 |
| FLA [A] 3) | 2.5 | 5 | 8 | |
| Max Frequency | 400 [Hz] 4) | |||
| Max Voltage | 3 Phase 200 ~ 230V 5) | |||
| Input Rating | Rated Voltage | 1phase 200~230 VAC (+10%, -15%) | ||
| Rated Frequency | 50 ~ 60 [Hz] (±5%) | |||
| Cooling Method | Forced Air Cooling | |||
| Weight [kg] | 0.76 | 1.12 | 1.84 | |
3-phase 200V Class
| SV ㅁㅁㅁ iG5A-2ㅁㅁ | 004 | 008 | 015 | 022 | 037 | 040 | 055 | 075 | 110 | 150 | 185 | 220 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Capacity 1) | [HP] | 0.5 | 1 | 2 | 3 | 5 | 5.4 | 7.5 | 10 | 15 | 20 | 25 | 30 |
| [kW] | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 4.0 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | |
| Output Rating | Capacity [kVA] 2) | 0.95 | 1.9 | 3.0 | 4.5 | 6.1 | 6.5 | 9.1 | 12.2 | 17.5 | 22.9 | 28.2 | 33.5 |
| FLA[A] 3) | 2.5 | 5 | 8 | 12 | 16 | 17 | 24 | 32 | 46 | 60 | 74 | 88 | |
| Max Frequency | 400 [Hz] 4) | ||||||||||||
| Max Voltage | 3 Phase 200 ~ 230V 5) | ||||||||||||
| Input Rating | Rated Voltage | 3 phase 200~230 (+10%, -15%) | |||||||||||
| Rated Frequency | 50~60 [Hz] (±5%) | ||||||||||||
| Cooling Method | N/C 6) | Forced Air Cooling | |||||||||||
| Weight [kg] | 0.76 | 0.77 | 1.12 | 1.84 | 1.89 | 1.89 | 3.66 | 3.66 | 9.0 | 9.0 | 13.3 | 13.3 | |
3-phsae 400V Class
| SV ㅁㅁㅁ iG5A-4ㅁㅁ | 004 | 008 | 015 | 022 | 037 | 040 | 055 | 075 | 110 | 150 | 185 | 220 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Capacity 1) | [HP] | 0.5 | 1 | 2 | 3 | 5 | 5.4 | 7.5 | 10 | 15 | 20 | 25 | 30 |
| [kW] | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 4.0 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | |
| Output Rating | Capacity [kVA] 2) | 0.95 | 1.9 | 3.0 | 4.5 | 6.1 | 6.9 | 9.1 | 12.2 | 18.3 | 22.9 | 29.7 | 34.3 |
| FLA [A] 3) | 1.25 | 2.5 | 4 | 6 | 8 | 9 | 12 | 16 | 24 | 30 | 39 | 45 | |
| Max Frequency | 400 [Hz] 4) | ||||||||||||
| Voltage [V] | 3 Phase 380 ~ 480V 5) | ||||||||||||
| Input Rating | Rated Voltage | 3 phase 380~480 VAC (+10%, -15%) | |||||||||||
| Rated Frequency | 50~60 [Hz] (±5%) | ||||||||||||
| Cooling Method | N/C 6) | Forced Air Cooling | |||||||||||
| Weight [kg] | 0.76 | 0.77 | 1.12 | 1.84 | 1.89 | 1.89 | 3.66 | 3.66 | 9.0 | 9.0 | 13.3 | 13.3 | |
1) Indicates the maximum applicable motor capacity when using the standard 4-pole LS motor.
2) Rated capacity is based on 220V for 200V series and 440V for 400V series.
3) Refer to 15-3 of the user manual when carrier frequency setting (39) is above 3kHz.
4) Max. frequency setting range is extended to 300Hz when H40 (Control mode select) is set to 3 (Sensorless vector control).
5) Max. output voltage cannot be higher than the input voltage. It can be programmable below the input voltage.
6) Self-Cooling
Detailed specification sheets are shown in the product images.