{"product_id":"lemo-b-series-push-pull-connector-141643","title":"LEMO B-Series Push Pull Connector","description":"\u003cp\u003e\u003cstrong\u003eSECURE HIGH-DENSITY PUSH-PULL CONNECTOR\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003ePEI-Genesis offers LEMO’s B-Series push-pull connector: a secure, push-pull latching system with high-density panel spacing, 360-degree EMI shielding, and quick mating or unmating. This LEMO push-pull connector series is designed for indoor or vacuum-tight applications, making it an ideal choice for test and measurement instrumentation, medical devices, research, audio\/video, and applications where a highly reliable, quick-mating connector is needed. Modular insert configurations include a wide range of high-density or hybrid electrical contacts, including solder, crimp, PCB straight or elbow, fiber, coax, thermocouple, pneumatic, fluidic, or high-voltage contacts. LEMO’s proprietary keying system allows for a higher contact density while preventing mismating. This LEMO push-pull connector series includes the family size range of 0B to 5B. PEI-Genesis’ Value Add Services are available for the LEMO B-Series with rapid turnaround. Contact us today to discuss your next application.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eSecure Push-Pull self-latching system\u003c\/li\u003e \u003cli\u003eSolder, crimp or PCB straight or elbow contacts\u003c\/li\u003e \u003cli\u003eMultiple key options to avoid mismating\u003c\/li\u003e \u003cli\u003e360 degree screening for full EMI shielding\u003c\/li\u003e \u003cli\u003eMultipole types: 2 to 64 contacts and hybrid electrical plus fiber, coax, thermocouple, pneumatic, fluidic or high voltage contacts\u003c\/li\u003e \u003cli\u003eHigh packing density for space savings on panel\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eMaterials \u0026amp; Finishes\u003c\/strong\u003e\u003c\/p\u003e \u003cdiv\u003e \u003cdiv\u003eShell\u003c\/div\u003e \u003cdiv\u003eBrass, Stainless Steel, Aluminum alloy\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eShell Plating\u003c\/div\u003e \u003cdiv\u003eChrome, Nickel, Black Chrome, Anodized, Nickel Antracite\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eContacts\u003c\/div\u003e \u003cdiv\u003eBrass or Bronze Beryllium with Stainless Steel Clips\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eContact Platings\u003c\/div\u003e \u003cdiv\u003eGold over Nickel over Copper\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eInsulator\u003c\/div\u003e \u003cdiv\u003ePEEK, PSU, PPSU, PA 6.6\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eO-ring and Gaskets\u003c\/div\u003e \u003cdiv\u003eSilicone\u003c\/div\u003e \u003c\/div\u003e \u003cp\u003e\u003cstrong\u003eElectrical Data\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eTest Voltage (Ue)\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eTest Voltage is dependant on contact and shell size, along with Insert Configuration.\u003cbr\u003eSee Insert Configuration Table.\u003c\/p\u003e \u003cp\u003eIt corresponds to 75% of the mean breakdown voltage.\u003cbr\u003eTest voltage is applied at 500 V\/s and the test duration is 1 minute.\u003cbr\u003eThis test has been carried out with a mated plug and socket, with power supply only on the plug end.\u003c\/p\u003e \u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOperating Voltage (Us):\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eIt is proposed according to the following ratio : Us = Ue\/3\u003c\/p\u003e \u003cp\u003eVoltage values are given in the table on insulator types for each series.\u003c\/p\u003e \u003cp\u003eThey correspond with values measured at sea level.\u003cbr\u003eThey are adapted to all applications up to an altitude of 2000m.\u003c\/p\u003e \u003cp\u003eIn case a device is used at a higher altitude, air clearance between live parts has to be multiplied by the following coefficients.\u003cbr\u003eIt means also that test voltage has to be divided by this coefficients.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eElectrical Data - Current Rating\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eCurrent Rating is dependant on contact and shell size, along with Insert Configuration.\u003cbr\u003eSee Insert Configuration Table.\u003c\/p\u003e \u003cp\u003eThe specified rated current can be applied simultaneously to all the contacts. It corresponds with an average temperature rise of 40°C of the connector.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/p\u003e \u003cdiv\u003e \u003cdiv\u003eWire Range Sizes\u003c\/div\u003e \u003cdiv\u003e30-8AWG AWG (stranded) or 28-10 AWG (solid)\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eMating Life\u003c\/div\u003e \u003cdiv\u003e\u0026gt;5,000 cycle, per IEC 60512-5 test 9a\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eSalt Spray\u003c\/div\u003e \u003cdiv\u003e\u0026gt;144 hours, per IEC 60512-6 test 11F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eOperating Temperature\u003c\/div\u003e \u003cdiv\u003e-55°C to +250°C (-67°F to 482°F)\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eProtection Index (mated)\u003c\/div\u003e \u003cdiv\u003eIP50, per IEC 60529, IP68 vacuumtight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eHumidity\u003c\/div\u003e \u003cdiv\u003eUp to 95% at 60°C\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eVibration\u003c\/div\u003e \u003cdiv\u003e10-2000 Hz, 15g per, IEC 60512-4 test 6d\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eShock\u003c\/div\u003e \u003cdiv\u003e100g, 6ms, per IEC 60512-4 test 6c\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eShielding Efficiency\u003c\/div\u003e \u003cdiv\u003eat 10 MHz \u0026gt;75 dB, per IEC 60169-1-3\u003cbr\u003eat 1 GHz \u0026gt;40 dB, per IEC 60169-1-3\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eContact Type\u003c\/div\u003e \u003cdiv\u003eSolder, Crimp, PCB (straight \u0026amp; right angle), thermocouple, co-ax, fiber optic, high voltage, first-mate last-break\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003eNumber of Circuits\u003c\/div\u003e \u003cdiv\u003e2 to 64 (See Insert Configuration Table)\u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003ePolarization\u003c\/div\u003e \u003cdiv\u003eIntegral Key(s) and Keyway(s)\u003c\/div\u003e \u003c\/div\u003e \u003cp\u003e\u003cbr\u003e*Steam sterilization\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eContact Resistance with Relation to the Number of Mating Cycles\u003c\/strong\u003e\u003cbr\u003eAverage values measured after the mating cycles and the salt spray test according to IEC 60512-6 test 11f.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eInsulation Resistance Between the Contacts and Contact\/Shell\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eNote: 1) 21 days at 95% RH according to IEC 60068-2-3.\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eContact Retention Force - Crimp Contacts\u003cbr\u003e\u003c\/strong\u003eSolder contacts are pressed fit and will have higher retention force.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e","brand":"LEMO S.A.","offers":[{"title":"Default Title","offer_id":58447519252820,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/84ad6707-a0f9-441c-91b3-afb879d4248d.jpg?v=1795193176","url":"https:\/\/premiumemart.com\/products\/lemo-b-series-push-pull-connector-141643","provider":"Premium Emart","version":"1.0","type":"link"}