{"product_id":"inline-thermal-mass-flowmeter-thermal-139832","title":"[Inline] Thermal Mass Flowmeter - Thermal 600-9","description":"\u003cp\u003e\u003cstrong\u003eThermal In-Line Flowmeter Model 600-9\/9500\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eWith Integrated Microelectronics\u003c\/p\u003e \u003cp\u003eA uniquely designed microprocessor controlled electronics provides integral local control and display in an explosion proof housing. Optional Remote Mounting of the electronics to a distance of 4000ft from the flow transducer provides additional versatility.\u003c\/p\u003e \u003cp\u003eFlow signal linearity and temperature effects, determined at calibration, are corrected by the microprocessor using operating parameter data stored in EEPROM memory.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow it works\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eIt's really very simple.\u003c\/p\u003e \u003cp\u003eOur Thermal Mass Flow Meters operate using a constant temperature system that employs two RTD sensors; one for sensing temperature, and one for sensing flow. The sensor is heated to a precise temperature above that of the fluid passing by.\u003c\/p\u003e \u003cp\u003eThe Fluid conducts heat off the sensor in direct proportion to the mass flow rate. The temperature is used to set the heat on the flow sensor and correct for changes in the fluid temperature.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eCompletely unobstructed flow; Sensor is incorporated into the outer surface protected from adverse conditions and out of the flow path.\u003c\/li\u003e \u003cli\u003eMinimal pressure loss; Straight tube design helps maintain steady pressure.\u003c\/li\u003e \u003cli\u003eRugged construction; Provides longer life and better performance.\u003c\/li\u003e \u003cli\u003eHandles a variety of materials; Can be used for liquids, slurries, gases, and homogenous solids.\u003c\/li\u003e \u003cli\u003eNo moving parts to break or wear out.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e +\/- .50% of Full Scale, [or 2.0% of reading whichever is better. Full Scale over the calibrated range. [Process fluid temperature span +\/- 50°F]\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eRepeatability: \u003c\/strong\u003e+\/- 0.2 % of Rate\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e\u003cbr\u003eGases: 1 to 2 sec. Typical\u003cbr\u003eLiquids: Less than 500ms\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003ePressure Rating:\u003c\/strong\u003e\u003cbr\u003e0 - 1200 psig (Std)\u003cbr\u003e0 - 10000 psig Dependent on meter size\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eMass Flow Rates:\u003c\/strong\u003e\u003cbr\u003eGases, Liquids: Consult factory for your application.\u003cbr\u003eNote: maximum determined by pipe capacity\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eFlow Range:\u003c\/strong\u003e 1OO:1 Capability\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eWetted Materials: \u003c\/strong\u003e316SS (STD). Consult factory for other material requirements\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003ePressure Drop Typically: \u003c\/strong\u003eSame as equivalent size and length tube or pipe\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eMounting: \u003c\/strong\u003eFlange; Tube Fittings, Sanitary, Welded. Many others available\u003cbr\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMICROPROCESSOR SPECIFICATIONS:\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eEEPROM Memory:\u003c\/strong\u003e 64 Byte\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eDisplays: \u003c\/strong\u003e8 digit Flowrate and Totalizer (Optional)\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eCommunicator:\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eInterface: \u003c\/strong\u003eRS-232 via Ribbon Connector\u003cbr\u003eBaud Rate: 9600\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eAdjustable Variables with RS-232 Communicator:\u003c\/strong\u003e\u003cbr\u003eZero Cutoff; Zero Offset\u003cbr\u003eDigital Filter Factor (damping 0 to 32 minutes)\u003cbr\u003eFlow Full Scale\u003cbr\u003eFlow Rate Decimal Point\u003cbr\u003eFlow Totalizer Decimal Point\u003cbr\u003eFlow Totalizer\/Flowrate Ratio\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003ePower: \u003c\/strong\u003e120\/240 vat, 50\/60 Hz, 20 Watts\u003cbr\u003e24VDC, 1 Amp (factory set)\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eElectrical Connections:\u003c\/strong\u003e 3\/4 ” FNPT Power \u0026amp; Signal\u003cbr\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Cast Aluminum, Epoxy Painted\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHousing: \u003c\/strong\u003eExplosion Proof, Class 1, Div. 1, Groups, B, C, D Weatherproof, Nema 4\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eAmbient Temperature: \u003c\/strong\u003e-25°C to 60°C ( -13°F to 140°F)\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 70°C ( -40°F to 158°F )\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cbr\u003eIntegral to the Flow Transducer\u003cbr\u003eRemote to 4000 ft., Wall or Frame mount\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSignal Cable for Remote Design: \u003c\/strong\u003e18 gauge, 2 pair with cable shield. Maximum distance, 4000 ft.\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eMODEL NUMBERING SYSTEM:\u003c\/strong\u003e\u003cbr\u003eBase Model: = 9500\u003cbr\u003eIn-Line: = 600-9\/9500\u003cbr\u003eTemperature Output: = 600-9\/9500\u003cbr\u003eElectronics Mounting\u003cbr\u003eI = Integral Mount\u003cbr\u003eR = In-Line , Remote Mount\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSize: \u003c\/strong\u003e1\/4'’ to 12”\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e\u003cbr\u003e316SS = STD\u003cbr\u003eOther = Consult Factory\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eDESIGN INTERIOR FINISH TYPE:\u003c\/strong\u003e\u003cbr\u003eIND = Industrial\u003cbr\u003eSAN= Sanitary\u003cbr\u003eUHP=Ultra High Pure\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eProcess Connection:\u003c\/strong\u003e\u003cbr\u003eSTB = Stub End for User Fitting.(STD.)\u003cbr\u003eTBE = Tube Fitting (STD.)\u003cbr\u003eWLD = Weld End (STD.)\u003cbr\u003eNPT = MNPT (STD.)\u003cbr\u003eFLG-150 = 150# RF Flange (STD.)\u003cbr\u003eFLG-OTHER = Consult Factory\u003cbr\u003eOTHER = Consult Factory\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003cbr\u003e24 = 22-26 VDC, 1 AMP. 4 WIRE\u003cbr\u003e120 = 120VAC, 50\/60 HZ (STD.)\u003cbr\u003e240 = 240VAC 50\/60 HZ\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eOutput Signals:\u003c\/strong\u003e\u003cbr\u003e(Select One**)\u003cbr\u003e0\/5 = 0-5 VDC**\u003cbr\u003e0\/10 = 0-10 VDC**\u003cbr\u003e4\/20 = 4-20 mADC** into 750 ohms, Isolated std, Self Powered\u003cbr\u003e4\/20T = Opt Process Fluid Temp. 4-20mA Self Powered\u003cbr\u003eOther = Consult Factory\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDisplay: \u003c\/strong\u003e(Optional)\u003cbr\u003eND = No Display\u003cbr\u003eD = Flowrate Display, 8 Digit\u003cbr\u003e8T = Totalizer\u003cbr\u003eD\/8T = Flowrate and Total Display, 8 digit\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSignal Cable for Remote Design:\u003c\/strong\u003e SC25 = 25 FT Supplied with remote configuration\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eGas Sizing Guide\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eLiquid Sizing Guide\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-9bed9e6e894632d4.pdf\" target=\"_blank\" rel=\"noopener\"\u003eManual-M\u0026amp;C Engineering-Thermal mass Flowmeter - Thermal-600-9 \/ 9500_2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-c33a73d95ae69936.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-M\u0026amp;C Engineering-Thermal mass Flowmeter - Thermal-600-9 \/ 9500_2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-570821d9aca7ccc5.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-M\u0026amp;C Engineering-Thermal mass Flowmeter - Thermal-600-9 \/ 9500\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"M\u0026C ENGINEERING","offers":[{"title":"Default Title","offer_id":58446752481620,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/e3c7fe08-3d99-4ec2-86cb-9f30585819d0.jpg?v=1795191619","url":"https:\/\/premiumemart.com\/products\/inline-thermal-mass-flowmeter-thermal-139832","provider":"Premium Emart","version":"1.0","type":"link"}