Thermal In-Line Flowmeter Model 600-9/9500

With Integrated Microelectronics

A uniquely designed microprocessor controlled electronics provides integral local control and display in an explosion proof housing. Optional Remote Mounting of the electronics to a distance of 4000ft from the flow transducer provides additional versatility.

Flow signal linearity and temperature effects, determined at calibration, are corrected by the microprocessor using operating parameter data stored in EEPROM memory.

How it works

It's really very simple.

Our Thermal Mass Flow Meters operate using a constant temperature system that employs two RTD sensors; one for sensing temperature, and one for sensing flow. The sensor is heated to a precise temperature above that of the fluid passing by.

The Fluid conducts heat off the sensor in direct proportion to the mass flow rate. The temperature is used to set the heat on the flow sensor and correct for changes in the fluid temperature.

  • Completely unobstructed flow; Sensor is incorporated into the outer surface protected from adverse conditions and out of the flow path.
  • Minimal pressure loss; Straight tube design helps maintain steady pressure.
  • Rugged construction; Provides longer life and better performance.
  • Handles a variety of materials; Can be used for liquids, slurries, gases, and homogenous solids.
  • No moving parts to break or wear out.

Specification

Accuracy: +/- .50% of Full Scale, [or 2.0% of reading whichever is better. Full Scale over the calibrated range. [Process fluid temperature span +/- 50°F]
 
Repeatability: +/- 0.2 % of Rate
 
Response Time:
Gases: 1 to 2 sec. Typical
Liquids: Less than 500ms
 
Pressure Rating:
0 - 1200 psig (Std)
0 - 10000 psig Dependent on meter size
 
Mass Flow Rates:
Gases, Liquids: Consult factory for your application.
Note: maximum determined by pipe capacity
 
Flow Range: 1OO:1 Capability
 
Wetted Materials: 316SS (STD). Consult factory for other material requirements
 
Pressure Drop Typically: Same as equivalent size and length tube or pipe
 
Mounting: Flange; Tube Fittings, Sanitary, Welded. Many others available
 
MICROPROCESSOR SPECIFICATIONS:
 
EEPROM Memory: 64 Byte
 
Displays: 8 digit Flowrate and Totalizer (Optional)
 
Communicator:
 
Interface: RS-232 via Ribbon Connector
Baud Rate: 9600
 
Adjustable Variables with RS-232 Communicator:
Zero Cutoff; Zero Offset
Digital Filter Factor (damping 0 to 32 minutes)
Flow Full Scale
Flow Rate Decimal Point
Flow Totalizer Decimal Point
Flow Totalizer/Flowrate Ratio
 
Power: 120/240 vat, 50/60 Hz, 20 Watts
24VDC, 1 Amp (factory set)
 
Electrical Connections: 3/4 ” FNPT Power & Signal
 
Enclosure: Cast Aluminum, Epoxy Painted

Environmental Rating

Housing: Explosion Proof, Class 1, Div. 1, Groups, B, C, D Weatherproof, Nema 4
 
Ambient Temperature: -25°C to 60°C ( -13°F to 140°F)
 
Storage Temperature: -40°C to 70°C ( -40°F to 158°F )
 
Mounting:
Integral to the Flow Transducer
Remote to 4000 ft., Wall or Frame mount
 
Signal Cable for Remote Design: 18 gauge, 2 pair with cable shield. Maximum distance, 4000 ft.
 
MODEL NUMBERING SYSTEM:
Base Model: = 9500
In-Line: = 600-9/9500
Temperature Output: = 600-9/9500
Electronics Mounting
I = Integral Mount
R = In-Line , Remote Mount
 
Size: 1/4'’ to 12”
 
Material:
316SS = STD
Other = Consult Factory
 
DESIGN INTERIOR FINISH TYPE:
IND = Industrial
SAN= Sanitary
UHP=Ultra High Pure
 
Process Connection:
STB = Stub End for User Fitting.(STD.)
TBE = Tube Fitting (STD.)
WLD = Weld End (STD.)
NPT = MNPT (STD.)
FLG-150 = 150# RF Flange (STD.)
FLG-OTHER = Consult Factory
OTHER = Consult Factory
 
Power:
24 = 22-26 VDC, 1 AMP. 4 WIRE
120 = 120VAC, 50/60 HZ (STD.)
240 = 240VAC 50/60 HZ
 
Output Signals:
(Select One**)
0/5 = 0-5 VDC**
0/10 = 0-10 VDC**
4/20 = 4-20 mADC** into 750 ohms, Isolated std, Self Powered
4/20T = Opt Process Fluid Temp. 4-20mA Self Powered
Other = Consult Factory

Display: (Optional)
ND = No Display
D = Flowrate Display, 8 Digit
8T = Totalizer
D/8T = Flowrate and Total Display, 8 digit
 
Signal Cable for Remote Design: SC25 = 25 FT Supplied with remote configuration

Dimension

Gas Sizing Guide

Liquid Sizing Guide

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
[Inline] Thermal Mass Flowmeter - Thermal 600-9

[Inline] Thermal Mass Flowmeter - Thermal 600-9

$0.00

[Inline] Thermal Mass Flowmeter - Thermal 600-9: overview and buying guide

The [Inline] Thermal Mass Flowmeter - Thermal 600-9 (model 600-9) is made by M&C ENGINEERING and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the [Inline] Thermal Mass Flowmeter - Thermal 600-9 cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the [Inline] Thermal Mass Flowmeter - Thermal 600-9 to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine M&C ENGINEERING product?

We purchase directly from M&C ENGINEERING or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

Thermal In-Line Flowmeter Model 600-9/9500

With Integrated Microelectronics

A uniquely designed microprocessor controlled electronics provides integral local control and display in an explosion proof housing. Optional Remote Mounting of the electronics to a distance of 4000ft from the flow transducer provides additional versatility.

Flow signal linearity and temperature effects, determined at calibration, are corrected by the microprocessor using operating parameter data stored in EEPROM memory.

How it works

It's really very simple.

Our Thermal Mass Flow Meters operate using a constant temperature system that employs two RTD sensors; one for sensing temperature, and one for sensing flow. The sensor is heated to a precise temperature above that of the fluid passing by.

The Fluid conducts heat off the sensor in direct proportion to the mass flow rate. The temperature is used to set the heat on the flow sensor and correct for changes in the fluid temperature.

  • Completely unobstructed flow; Sensor is incorporated into the outer surface protected from adverse conditions and out of the flow path.
  • Minimal pressure loss; Straight tube design helps maintain steady pressure.
  • Rugged construction; Provides longer life and better performance.
  • Handles a variety of materials; Can be used for liquids, slurries, gases, and homogenous solids.
  • No moving parts to break or wear out.

Specification

Accuracy: +/- .50% of Full Scale, [or 2.0% of reading whichever is better. Full Scale over the calibrated range. [Process fluid temperature span +/- 50°F]
 
Repeatability: +/- 0.2 % of Rate
 
Response Time:
Gases: 1 to 2 sec. Typical
Liquids: Less than 500ms
 
Pressure Rating:
0 - 1200 psig (Std)
0 - 10000 psig Dependent on meter size
 
Mass Flow Rates:
Gases, Liquids: Consult factory for your application.
Note: maximum determined by pipe capacity
 
Flow Range: 1OO:1 Capability
 
Wetted Materials: 316SS (STD). Consult factory for other material requirements
 
Pressure Drop Typically: Same as equivalent size and length tube or pipe
 
Mounting: Flange; Tube Fittings, Sanitary, Welded. Many others available
 
MICROPROCESSOR SPECIFICATIONS:
 
EEPROM Memory: 64 Byte
 
Displays: 8 digit Flowrate and Totalizer (Optional)
 
Communicator:
 
Interface: RS-232 via Ribbon Connector
Baud Rate: 9600
 
Adjustable Variables with RS-232 Communicator:
Zero Cutoff; Zero Offset
Digital Filter Factor (damping 0 to 32 minutes)
Flow Full Scale
Flow Rate Decimal Point
Flow Totalizer Decimal Point
Flow Totalizer/Flowrate Ratio
 
Power: 120/240 vat, 50/60 Hz, 20 Watts
24VDC, 1 Amp (factory set)
 
Electrical Connections: 3/4 ” FNPT Power & Signal
 
Enclosure: Cast Aluminum, Epoxy Painted

Environmental Rating

Housing: Explosion Proof, Class 1, Div. 1, Groups, B, C, D Weatherproof, Nema 4
 
Ambient Temperature: -25°C to 60°C ( -13°F to 140°F)
 
Storage Temperature: -40°C to 70°C ( -40°F to 158°F )
 
Mounting:
Integral to the Flow Transducer
Remote to 4000 ft., Wall or Frame mount
 
Signal Cable for Remote Design: 18 gauge, 2 pair with cable shield. Maximum distance, 4000 ft.
 
MODEL NUMBERING SYSTEM:
Base Model: = 9500
In-Line: = 600-9/9500
Temperature Output: = 600-9/9500
Electronics Mounting
I = Integral Mount
R = In-Line , Remote Mount
 
Size: 1/4'’ to 12”
 
Material:
316SS = STD
Other = Consult Factory
 
DESIGN INTERIOR FINISH TYPE:
IND = Industrial
SAN= Sanitary
UHP=Ultra High Pure
 
Process Connection:
STB = Stub End for User Fitting.(STD.)
TBE = Tube Fitting (STD.)
WLD = Weld End (STD.)
NPT = MNPT (STD.)
FLG-150 = 150# RF Flange (STD.)
FLG-OTHER = Consult Factory
OTHER = Consult Factory
 
Power:
24 = 22-26 VDC, 1 AMP. 4 WIRE
120 = 120VAC, 50/60 HZ (STD.)
240 = 240VAC 50/60 HZ
 
Output Signals:
(Select One**)
0/5 = 0-5 VDC**
0/10 = 0-10 VDC**
4/20 = 4-20 mADC** into 750 ohms, Isolated std, Self Powered
4/20T = Opt Process Fluid Temp. 4-20mA Self Powered
Other = Consult Factory

Display: (Optional)
ND = No Display
D = Flowrate Display, 8 Digit
8T = Totalizer
D/8T = Flowrate and Total Display, 8 digit
 
Signal Cable for Remote Design: SC25 = 25 FT Supplied with remote configuration

Dimension

Gas Sizing Guide

Liquid Sizing Guide

Detailed specification sheets are shown in the product images.